• Title/Summary/Keyword: 정량적 기준

Search Result 1,916, Processing Time 0.028 seconds

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

Analysis of didecydimethylammonium chloride (DDAC) aerosol in inhalation chamber (흡입챔버 내 didecyldimethylammonium chloride(DDAC) 에어로졸의 분석)

  • Yang, Jeong-Sun;Choi, Sung-Bong;Park, Sang-Yong;Lee, Sung-Bae
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.307-312
    • /
    • 2012
  • To perform inhalation toxicity test by using experiment animals, we set up an analytical method to monitor didecyldimethylammonium chloride (DDAC) in aerosol nebulized into inhalation chambers by ion chromatography. DDAC was adsorbed by XAD-2 resin and analyzed with conductivity detector. Recovery of DDAC desorbed by acetonitrile from XAD adsorbent was 87.8%. The method detection limit (MDL) and the limit of quantitation (LOQ) were 2.97 ${\mu}g/m^3$ and 8.92 ${\mu}g/m^3$, respectively. Repeatability was calculated as RSD 7.8% in the range of 0~20 ${\mu}g/mL$. Time needed to analyze a sample was less than 5 minutes. Therefore, the analysis of DDAC by ion chromatography was practically useful in monitoring DDAC in inhalation chambers with rapidity and sensitivity manner to perform inhalation toxicity test using experimental animals.

Analytical Method of Silicon Dioxide in Health Functional Food Products using ICP-OES

  • Ka, Mi-Hyun;Lee, Kwang-Geun;Lim, Heung-Youl;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Kim, Yong-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.343-347
    • /
    • 2017
  • The analytical method of silicon dioxide ($SiO_2$) in health functional food products was developed employing inductively coupled plasma optical emission spectrometry (ICP-OES) method assisted by acid (hydrofluoric acid and boric acid) digestion in open system without alkali fusion. The limit of detection (LOD) and limit of quantification (LOQ) of this method were found to be 0.07 and 0.20 mg/L, respectively. Linearity ($r^2$) and linear range were 0.99 and 0.20~20.0 mg/L, respectively. The accuracy and precision of $SiO_2$ (0.4, 1.0, and 2.0%, w/w) in spiked glucosamine exhibited to be the range of 90.22~94.14% and 0.72~1.67%, respectively. The contents of $SiO_2$ in 11 health functional food products were detected in range of 0.02~1.80% (w/w). Every sample showed below content of the permitted use level (2%, w/w) of $SiO_2$. Therefore ICP-OES method with acid can analyze the content of $SiO_2$ in health functional food products easily and rapidly. Consequently, the application of specification analysis of $SiO_2$ in health functional food products could be a significant work.

Dissolution Profile Analysis of Hydroxypropyl Methylcellulose-based Vitamin C Tablets (Hydroxypropyl methylcellulose를 활용한 비타민 C 지속성 정제의 용출 특성 분석)

  • Cha, Ja-Hyun;Hong, Jun-Kee;Lee, Sung-Wan;Cha, Jae-Uk;Ko, Won-Hwa;Baek, Hyon-Ho;Park, Hyun-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.274-279
    • /
    • 2012
  • The objective of this study was to develop oral matrix tablets for the sustained release of vitamin C. In this study hydroxypropyl methylcellulose (HPMC) has been utilized as an excipient, as it is one of the most widely used polymers, for use during long periods of time in formations. The vitamin C tablet formulation depends on the molecular weight and concentration of sustained-delivery in HPMC. Anti-oxidants have been added as a dissolution medium in order to prevent vitamin C degradation in water. The dissolution test was carried out in a distilled water medium, and the release model equation was applied to analyze the vitamin C release pattern. The results demonstrated that the release and lasting power of vitamin C tablets, containing HPMC, lasted for more than 12 h.

Effect of tDCS Stimulation for Improving Working Memory on Stroke Patients' EEG Variation (작업기억의 향상을 위한 tDCS 자극이 뇌졸중 환자의 뇌파변화에 미치는 영향)

  • Bae, Si-Jeol;Jeong, Woo-Sik;Lee, Hong-Gyun;Kim, Kyung-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.261-272
    • /
    • 2012
  • This study was conducted so as to examine which change tDCS (Transcranial Direct Current Stimulation) for improving working memory can make on the EEC of stroke patients. Among the patients who suffered for more than 6 months by hemiparalysis caused by stroke, 20 patients selected by MMSE and DST were randomly divided into I group (10 patients) fulfilled by only CCT and II group (10 patients) fulfilled by both tDCS and CCT for total 4 weeks, 30 minutes per a day, three times per a week. For examining EEC variation, the absolute spectrum power was calculated by three bands (${\theta}$; 4~8 Hz, lower ${\alpha}$; 8~10.5 Hz, upper ${\alpha}$;10.5~13 Hz) during the task of words, photos and mental calculation with EEC test, before the arbitration, after 2 weeks and after 4 weeks, so the rate of increase and decrease (%) for the reference EEC was obtained. As the results, the first, particular aspects different one another in three bands were detected according to the measuring period and task. The second, in the forth week, there was only a significant difference in lower ${\alpha}$-power of all tasks. Therefore, through the procedure measuring EEC of this study, the degree of working memory's damage can be expressed by numerical value and tDCS should be additionally helpful for brain damaged patients' perception rehabilitation.

Discrimination of Native Bee-Honey and Foreign Bee-Honey by SDS-PAGE (단백질 전기영동을 이용한 토종꿀의 판별)

  • Lee, Deug-Chan;Lee, Sang-Young;Cha, Sang-Hoon;Choi, Yong-Soon;Rhee, Hae-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.1-5
    • /
    • 1998
  • To find out the difference between native bee-honey (NBH) and foreign bee-honey (FBH), quantification of honey protein and investigation of specific protein in NBH were carried out by SDS-PAGE. Contents of honey protein in NBH and FBH were measured by Bradford and Lowry method. The contents of protein determined by Bradford method were $0.1{\sim}3.3\;mg/g$ in NBH and $0.2{\sim}1.6\;mg/g$ in FBH, and by Lowry method were $12.9{\sim}45.7\;mg/g$ in NBH and $15.8{\sim}27.1\;mg/g$ in FBH. In order to investigate the distribution of bee honey proteins, the SDS-PAGE was performed. The results showed that molecular weight of the major proteins in NBH and in FBH were 56 kDa and 59 kDa. respectively. Therefore, it was confirmed that the difference between NBH and FBH can be identified visually by SDS-PAGE analysis. The major proteins in NBH and FBH were purified through two step chromatography, and the obtained proteins were used as marker protein in SDS-PAGE to discriminate NBH and FBH.

  • PDF

Changes in Flavor Characteristics and Shelf-life of Roasted Coffee in Different Packaging Conditions during Storage (포장 조건에 따른 저장 중 커피의 향미 특성의 변화와 보존 기간)

  • Moon, Jun-Woong;Cho, Jae-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.441-447
    • /
    • 1999
  • Changes in flavor characteristics of roasted coffee in 6 package models during storage were investigated by GC/MS analysis and sensory evaluation to establish the criteria of the shelf-life of the roasted coffee in three flavor quality-'fresh', 'satisfying' and 'minimally acceptable' levels. In direct headspace method of GC/MS, 47 volatile compounds were analyzed and the light volatile compounds were reduced sharply at initial stage of storage and faster in the package with air. The correlation between % retention of 2,3-butanedione and overall aroma of roasted coffee showed good linear-relation, of which correlation coefficient (R) were from 0.999 to 0.904 depending on package models, indicating that 2,3-butanedione would be an index chemical for evaluating the freshness of roasted coffee. In sensory evaluation of 6 package models during storage, roasted whole beans (RB) and roasted and ground (RG) coffee in air-package were preserved in 'fresh quality' for $0.5{\sim}1$ week, 'satisfying quality' for $2{\sim}3$ weeks and 'minimally acceptable quality' for 12 weeks, while roasted whole beans in valve-package and roasted and ground coffees in vacuum-package, nitrogen-package and oxygen absorbent-package were preserved in 'fresh quality' for $2{\sim}4$ weeks, 'satisfying quality' for $12{\sim}24$ weeks and 'minimally acceptable quality' for 52 weeks. The oxygen absorbent-package was slightly less effective than other three methods.

  • PDF

A Study of Platform for Management and Real-Time Service of Distributed Objects (분산 객체들의 관리와 실시간 서비스를 위한 플랫폼의 연구)

  • Kim, Myung-Hee;Joo, Su-Chong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.10a
    • /
    • pp.297-300
    • /
    • 2001
  • 최근의 컴퓨팅 환경은 이질적인 클라이언트와 서버들간의 상호 운용성을 요구하는 분산 어플리케이션을 위한 프로그래밍 파라다임을 지원하기 위한 분산 객체 컴퓨팅 환경으로 발전되고 있다. 여기에는 복잡한 네트워킹과 다양한 멀티미디어 응용 서비스를 위한 객체지향 기술들이 접목되고 있다. 이러한 분산 컴퓨팅 환경에서 처리되는 어플리케이션들의 실시간 서비스 지원을 위해 요구되는 실시간 특성과 분산 객체들의 관리의 어려움을 해결하기 위하여 본 논문에서는 실시간 객체그룹 플랫폼을 구축한다. 기존의 연구들은 실시간 CORBA를 사용하거나 또는 ORB를 수정하거나 실시간 운영체제상에 특정 CORBA 제품군을 사용하여 분산 환경의 특정 영역의 성능향상만을 도모하고 있다. 그러므로, 본 논문은 ORB의 수정 없이 표준 CORBA상에서 실시간 특성을 지원한 수 있는 실시간 객체그룹 플랫폼을 설계한다. 본 논문의 실시간 객체그룹 구조는 객체들의 관리적인 측면과 실시간 어플리케이션 서비스 지원 측면에 대한 요구사항들을 분석하여 정립한 모델이며, 구성요소들의 기능을 관리와 서비스로 분리하여 각각의 기능수행시에 발생하는 객체간의 상호작용이 다른 기능에 영향을 미치지 않도록 한다. 또한, 구축된 플랫폼은 실시간 어플리케이션 개발자에게 실시간 특성 파라미터의 표현과 처리에 대한 투명성을 부여하여 어플리케이션에 유연성과 확장성을 제공하기가 용이하도록 한다. 따라서, 본 논문은 실시간 객체그룹 플랫폼의 구성요소들에 대한 역할을 정의하고 기능을 정립하며, 각 구성요소들을 설계하고 구현하였으며, 구현되어진 실시간 객체그룹 플랫폼의 기능과 수행 성능을 검증한다.가지 유기화합물 중에서는 35.6%를 차지하였다. BTEX 각각 개별물질은 미국 환경보호청이 제시하는 일일 노출 기준량(Reference Concentration; RfC) 보다는 현저히 낮았다. 총 휘발성 유기화합물읜 농도는 실내가 실외 보다 높았다(I/O ratio 2.5). BTEX의 상대적 함량도 실내가 실외보다 높아 실내에도 발생원이 있음을 암시하고 있다. 자료 분석결과 유치원 실내의 벤젠은 실외로부터 유입되고 있었고, 톨루엔, 에틸벤젠, 크실렌은 실외뿐 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타

  • PDF

Determination of Chloramphenicol by Differential Pulse Polarography (미분 펄스 폴라로그래피에 의한 Chloramphenicol의 정량분석)

  • Younghee Hahn;Jung-Sun Jeon
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.4
    • /
    • pp.552-557
    • /
    • 1992
  • Chloramphenicol was studied by differential pulse polarography (DDP). A reduction peak which is dependent on pH of the solution appeared in the voltage range between zero and -1.50 volt vs. Ag/AgCl (sat. KCl) reference electrode. A plot of peak potentials (Ep) measured at room temperature (20$^{\circ}C$) vs. pH of the chloramphenicol solutions showed linear relationship changing slope (Ep/pH) at pH 8.9. The slope was -59.7 mV/pH in pH 2.7∼8.9 and -24.3 mV/pH in pH 8.9∼11.2, respectively. A log plot of peak currents (ip) vs. concentrations showed a linearity at the concentrations between 4.8 ${\times}$ 10$^{-7}$ M and 6.2 ${\times}$ 10$^{-5}$ M (0.16 ppm∼20 ppm) chloramphenicol in pH 8.0 ammonium buffer. Between the DPP method and the reference method measuring absorbance at 278 nm, the correlation coefficient was 0.996, which means an excellent linearity. The DPP method was able to detect degradation products of chloramphenicol in mild alkaline solution (pH = 8.0) more distinctly than the spectrophotometric method.

  • PDF

Correlation between Cutometer and Quantitative Evaluation Using Moire Topography in Age-related Skin Elasticity (Morie Topography를 이용한 피부 탄력 평가와 Cutometer 결과와의 상관성 연구)

  • Ahn, Sung-Yeon;Bae, Ji-Hyun;Kim, Seung-Hun;Lee, Hae-Kwang;Moon, Seong-Joon;Chang, Ih-Seop;Lee, Ok-Sub
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.343-347
    • /
    • 2005
  • As aging occurs, ow skin gets more wrinkles, becomes drier and loses its elasticity. Validating the evaluation of skin elasticity is especially important, because it is not as visible as other signs of aging such as wrinkles. Here, we identified the correlation between age and the Parameters given by Cutometer, and (we present) the parameters of that reflect the decreases in skin elasticity along with ages (Ur/Uf, Ua/Uf, Ur/Ue, Ua, $r=0.687{\sim}0.725$). Also we developed an evaluation method to quantify the difference of skin by viewing or touching. A five-grade standard of Moire topographic photo scale on face was prepared using sensory evaluation of 20 to 61 year - old women. Based on this photo standard, scoring was performed using (a) 5-grade system by three specialists to obtain the consensus score. Significant negative correlations between age and results of Cutometer $(r=-0.687{\sim}-0.725)$, Moire topography scores (r=-938) were found. Finally we have shown the significance of the correlation between the result of Cutometer and the score of Moire topography (r=0.711). Our studies using Moire topography on face have confirmed that instrumental measurements reflect the decrease in shin elasticity, which is perceived visually.