• Title/Summary/Keyword: 정격

Search Result 699, Processing Time 0.025 seconds

Comparison of Response Properties Determined in Two Torque Control Methods for a 2.75-MW Wind Turbine Under Turbulence Wind Speed (난류풍속에 대한 MW급 풍력터빈의 토크제어 방법에 따른 응답 특성 비교)

  • Lim, Chae-Wook;Seo, Kang-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1885-1891
    • /
    • 2010
  • Torque control of wind turbines is important when the wind speed is below the rated speed. The main objective of torque control is to extract the maximum power from the potential aerodynamic power of the wind. Torque control methods for wind turbines are classified as torque-mode control and speed-mode control. In torque-mode control, which is well known and traditionally used in many wind turbines, the torque demand of the generator is proportional to the square of the generator speed. In speed-mode control, a PI controller is used to generate the appropriate torque demand of the generator. In this study, the two torque control methods mentioned above are applied to a 2.75-MW wind turbine; simulation results for real turbulence wind speeds are presented, and the response properties are compared.

Development of 6-axis force/moment sensor for an intelligent robot's foot (지능형 로봇 발을 위한 6 축 힘/모멘트센서 개발)

  • Kim, Gab-Soon;Shin, Hyi-Jun;Hu, Duk-Chan;Yoon, Jung-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1097-1102
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor for an intelligent robot's foot. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself. The applied forces and moments should be measured from a 6-axis force/moment sensor attached to a humanoid robot's foot(ankle). They in the published paper already have some disadvantage in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to be gotten similar the rated output under each rated load. So, the sensing elements of the 6-axis force/moment sensor should get lots of design variables. Also, the size of 6- axis force/moment sensor is very important for mounting to robot's foot. In this paper, a 6-axis force/moment sensor for perceiving forces and moments in a humanoid robot's foot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing elements (plate-beams) of the sensor were designed using FEM (Finite Element Method) analysis. Then, the 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with that from the characteristic test.

  • PDF

The effects of Sa-am Acupuncture Simpojeongkyeok Treatment on Hwa-byung : Randomized, patient-assessor blind, placebo-controlled acupuncture, pilot clinical trial (화병에 대한 사암침 심포정격의 치료 효과 : 환자-평가자 눈가림, 무작위배정 대조군 임상시험)

  • Choi, Woo-Jin;Lee, Seung-Gi;Son, In-Bong;Sun, Seung-Ho
    • Journal of Oriental Neuropsychiatry
    • /
    • v.22 no.2
    • /
    • pp.1-13
    • /
    • 2011
  • Objectives : The purpose of this research is to examine the effects of Sa-am acupuncture Simpojeongkyeok treatment on Hwa-byung. Methods : The study was performed through a patient-assessor blind, randomized, placebo-controlled trial in which the volunteers, data collector and analyst were unaware of individuals which were receiving the treatment. Fifty volunteers were divided into a trial and a control group, each of which consisted of 25 subjects. The trial group was treated with Sa-am acupuncture Simpojeongkyeok, while needle insertion at non-acupoints was given to the control group. The Likert scale for major symptoms of Hwa-byung was measured as the 1st evaluative instrument, and then a comparative analysis was conducted by comparing the results with those measured by of STAXI-K, STAI-K and BDI-K. Results : In the Likert scale comparison of major symptoms, total scores in both groups were decreased after treatment. However, a more significant decrease was found in those of trial group compared to those of the control group from a statistical perspective. The results measured by BDI scores also decreased significantly in the trial group after treatment. In comparison of STAXI and STAI scores, there were no significant differences found between the groups. Conclusions : The results suggest that Sa-am Acupuncture Simpojeongkyeok treatment is effective in the treatment of Hwa-byung.

An Automatic AC-DC Transfer Error Measurement System (교류-직류 변환오차 자동 측정시스템)

  • Kwon, Sung-Won;Cho, Y.M.;Kim, K.T.;Kang, J.H.;Park, Y.T.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.401-408
    • /
    • 1998
  • A dual-channel automatic ac-dc voltage transfer error measurement system in which the output voltages of two thermal voltage converters which are ac voltage standard are directly measured at the same time to reduce the output voltage drift is described. Forward-reverse measurement method by using a two-channel scanner is used to cancel the offset voltage of the voltmeters. The agreements of the 4-V TVC comparison results between other national standards institute and Korea Research Institute of Standards and Science were less than about ${\pm}2\;ppm$ in the frequency range of $40\;Hz{\sim}100\;kHz$, and were less than about ${\pm}4\;ppm$ at $200\;kHz{\sim}1\;MHz$. Measurement uncertainty is reduced significantly from ${\pm}4\;ppm$ of manual system to ${\pm}3\;ppm$ of new system(up to 100 kHz) typically and great increase in comparison efficiency has been achieved by this system.

  • PDF

An Evaluation of Weather Model for Increasing Ampacity in KEPCO's Overhead Transmission Lines (한국전력 가공송전선의 허용전류를 증가시키기 위한 기상모델의 평가)

  • 김성덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.125-134
    • /
    • 2004
  • The new deregulated economic environment in the power utility market is forcing fundamental changes in the investment and operational decisions regarding transmission lines. Hence, it has come to be an important issue to evaluate their current utility in order to increase conductor ampacity based on conservative assumptions of worst case weather conditions. Static thermal rating has born still applied in most power companies worldwide, however some of them have been done various trials such as monitoring dynamic line ratings to increase line ratings in real time. This study is an attempt to access the static line ratings in Korea Electric Power Corporation(KEPCO) transmission lines, which were specified by weather model. Several environmental performances for determining static line ratings are examined by using the past weather data of Korean Meteorological Administration. As a result, it is shown that seasonal or regional line ratings could be adopt to the KEPCO's transmission lines, and their line ratings could be more increased without refurbishing current conductors in service to new high-temperature ones.

The Modeling Analysis of the AT Forward Multi-Resonant Converter (AT 포워드 다중공진형 컨버터의 모델링 해석)

  • 김창선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.6-14
    • /
    • 2000
  • The high efficiency multi-resonant converter(MRC) is capable of operating at a high frequency because the losses are decreased due to the resonant tank circuit. Such a few MHz high frequency applications provide high power density[W/inch3] of the converter. However, the resonant voltage stress across the switch of the resonant tank circuit is 4∼5 times input voltage. This high voltage stress increases the conduction losses because of on-resistance of a MOSFET with higher rating. In this paper, the modeling analysis for the AT Forward MRC suggested to solve the these problems is discusses. The operational modes of the AT Forward MRC are divided to 8 equivalent modes according to the two switching sequences. Each mode analysis is covered using the equivalent circuits modeled over all of the paper. The operational principle of the resonant converter was verified through the experimental converter with 48[V] input voltage, 5[V]/50[W] output voltage/power and PSpice simulation. The measured maximum voltage, 5[V]/50[W] output voltage/power and PSpice simulation. The measure maximum voltage stress is 170[V] of 2.9 times the input voltage and the maximum efficiency is measured to 81.66%.

  • PDF

Operating Characteristics of Molded Case Circuit Breakers by Harmonic Currents (고조파 전류에 의한 배선용 차단기 동작 특성)

  • Jeon, Jeong-Chay;Yoo, Jae-Geun;Lee, Sang-Ick
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.68-74
    • /
    • 2006
  • Malfunction and nuisance tripping of molded case circuit breaker(MCCB) caused by harmonic currents have been reported. But no data is available on the behavior of MCCB under harmonic currents. This paper tested the effects of harmonic currents on four common types of MCCB(thermal, thermal magnetic, magnetic and electronic types). Results of experiment detected no nuisance tripping with any of the breakers tested under test currents, included harmonic current, below rated currents. Additionally it was found that varying harmonic loading conditions did not affect manufacturer specified trip times for thermal only and thermal magnetic circuit breakers. However, under overloaded conditions, trip times of the magnetic only circuit breakers were gradually slowed according to increasing of harmonic currents, and it could cause hazardous overheating of cables. So, the use of magnetic only circuit breakers in the place harmonic currents we serious must be avoided.

Optimal Rotor Blade Design for Tidal In-stream Energy (조류발전용 로터 블레이드의 최적 형상 설계)

  • Yang, Chang-Jo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.75-82
    • /
    • 2011
  • Marine current energy is one of the most interesting renewable and clean energy resources that have been less exploited. Especially, Korea has worldwide outstanding tidal current energy resources and it is highly required to develop tidal in-stream energy conversion system in coastal area. The objective of study is to investigate harnessing techniques of tidal current energy and to design the a 100 kW horizontal axis tidal turbine using blade element momentum theory with Prandtl's tip loss factor for optimal design procedures. In addition, Influence of Prandtl's tip loss factor at local blade positions as a function of tip speed ratio was studied, and the analysed results showed that power coefficient of designed rotor blade using NACA 63812 was 0.49 at rated tip speed ratio.

Study on the Relationship between Dae-Jang-Jung-Gyeok(大腸正格) and Leaky Gut Syndrome (대장정격증(大腸正格證)과 장누수증후군(Leaky Gut Syndrome)과의 관계 고찰(考察))

  • Lee, Jin-Cheoul;Park, Sang-Kyun;Bang, Jung-Kyun
    • Journal of Korean Medical classics
    • /
    • v.26 no.4
    • /
    • pp.105-116
    • /
    • 2013
  • Objective : If the penetration ratio of the intestinal mucosa is increased, the toxic or unhealthy materials - which should not be absorbed into our bodies - will be come into our bodies. They cause a sort of anti-toxic response or confusion of the immune system, and ultimately bring various types of diseases. This syndrome is related "Poison in Excrement" or "Internal Damage(內傷發癍)" and Leaky Gut Syndrome, so I will study on the relationship between them. Method : Study on the relationship between Dae-Jang-Jung-gyeok and Leaky Gut Syndrome. Result : Korean doctors in ancient times called this syndrome "Poison in Excrement" or "Internal Damage(內傷發癍)" and treated it with "Dae-Jang-Jung-Gyeok(大腸正格)". Leaky Gut Syndrome is a sort of clinical lesion, which allows foreign and harmful toxins in and results in a disorder of the immune system due to the leaking intestinal mucosa. Conclusion : Based upon the analyses, Dae-Jang-Jung-Gyeok and Leaky Gut Syndrome are closely related. Therefore diseases caused by the Leaky Gut Syndrome might be expected to be cured by Dae-Jang-Jung-Gyeok. Particularly the use of treatments for self-immune diseases and allergic diseases such as atopyic dermatitis and articular rheumatism should be expected to reveal a new path of treatment for other disorders such as Leaky Gut Syndrome.

Design, fabrication, and evaluation of RF module in compliance with the IEEE 802.11a standard for 5GHz-band Wireless-LAN applications (IEEE 802.11a 규격을 만족하는 5GHz 대역 무선 랜용 RF 모듈의 설계, 제작과 성능 평가)

  • 권도훈;김영일;이성수;박현철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3C
    • /
    • pp.248-255
    • /
    • 2002
  • An RF module in compliance with the IEEE 802.11a standard has been designed and its performance has been measured. Conventional heterodyne architecture with 580MHz intermediate frequency has been realized. Measurement results show that the receiver has a low Noise Figure of 5dB, the maximum gain of 70dB, and dynamic range as wide as 61dB. Also, the SAW filter used for channel selection in the IF section allowed minimum inter-channel interference. in addition to satisfying the RF output power requirement, the transmitter features its output P1dB as high as 34dBm so that the high peak-to-average ratio of the Orthogonal Frequency Division Multiplexing (OFDM) modulation scheme can be handled with minimum nonlinear distortion. The output P1dB of 34dBm of the transmitter corresponds to back-off powers of 18dB and 11dB with respect to the output power for the low and the middle frequency bands, respectively.