• Title/Summary/Keyword: 접촉효율

Search Result 725, Processing Time 0.026 seconds

Study of Applicability for Removing Contaminants on Surface of Color Pigment Using the Laser Cleaning Technique -Focus on Analysis Method of Confocal Laser Scanning Microscope- (채색 안료 층의 표면오염물에 대한 레이저클리닝기법의 적용성 평가 연구 -공초점레이저주사현미경(CLSM)을 통한 분석평가 중심으로-)

  • Kim, Jin-Hyoung
    • Journal of Conservation Science
    • /
    • v.30 no.2
    • /
    • pp.123-136
    • /
    • 2014
  • Considering that decision in conservation treatment for damaged objects should consider not only various options of methodology of intervention but also possible consequences of different types of intervention, it is a difficult task to decide and propose clear and safest solution of preserving an object. In addition, it should be constantly challenged by conservators even if it is proved technique or methodology in a past treatment. Therefore, there is no absolute solution which can be applied to all practice but each decision can be different case by case. It is not possible to estimate the way how the present condition of material and environmental aspects would affect to the condition of an object in future. However if conservators keep trying to set out various ways of analysing pro and against effect of past treatments, it would be able to provide useful logics of proving efficiency and appropriateness of a certain treatment. Understanding that the advantage of laser technique is to adopt a way of cleaning an object without making a direct contact, which is different from other techniques, this paper aims at securing stability of laser techniques, although it remains a limitation in the compatibility to all other materials. This study has examined reacting process on the painted pigments against laser beam by using CLSM in order for it to display both the problems from such reacting process and the efficiency of it as a cleaning methodology. It has intended to estimate the result of laser techniques and propose the range of applicability.

Study on the Standardization of a Surveillance Culture Laboratory in Infection Control Fields (감염관리 분야에서 감시배양검사의 표준화 연구)

  • Park, Chang-Eun;Jeong, Na-Yeon;Yang, Min-Ji;Kim, Han-Wool;Joo, Sei-Ick;Kim, Keon-Han;Seong, Hee-Kyung;Hwang, Yu-Yean;Lim, Hyun-Mi;Son, Jae-Cheol;Yoon, Sun-Han;Yoon, Nam-Seob;Jang, In-Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.359-369
    • /
    • 2018
  • An essential measure to prevent healthcare-associated infections (HAI) is to develop a consistent system of surveillance, thereby promoting a reliable situation diagnosis to perform efficient control for the problem. Patient-to-patient transmission of pathogens within the hospital plays a substantial role in the epidemiology of HAIs. Contamination of healthcare environments commonly occurs, including facilities surfaces (e.g., bed rails, bedside tables), drinking water, cooling tower water, endoscopic instruments, food, airborne, endotoxin test, sterile test and medical equipment, with pathogenic organisms. In addition, epidemiological analysis is performed by multi locus sequence tying, pulsed-field gel electrophoresis for active surveillance. Therefore, an environmental surveillance culture test for prevention improves patient safety and blocks infection agents. Effective infection control and increased safety are possible by controlling the national infection control system. In conclusion, this study contributes to an effective infection control system through the standardization of active surveillance culture laboratory and secure expertise as infection control specialist. The primary objective of the standardization is to improve the safety of the nation's healthcare system by reducing the rates of HAIs.

Oxidation of Phenol Using Ozone-containing Microbubbles Formed by Electrostatic Spray (전기장에 의해 생성된 미세기포를 이용한 페놀의 오존산화)

  • Shin, Won-Tae;Jung, Yoo-Jin;Sung, Nak-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1292-1297
    • /
    • 2005
  • The use of ozone in water and wastewater treatment systems has been known to be a process that is limited by mass transfer. The most effective way to overcome this limitation is to increase the interfacial area available for mass transfer by decreasing the size of the ozone gas bubbles that are dispersed in solution. Electrostatic spraying(ES) of ozone into water was investigated in this work as a method of increasing the rate of mass transfer of ozone into a solution and thereby increasing the rate of phenol oxidation. Results were obtained for ES at input power levels ranging from 0 to 4 kV and compared with two different pore-size bubble diffusers($10{\sim}15{\mu}m$ and $40{\sim}60{\mu}m$). It was determined that the rate of mass transfer could be increased by as much as 40% when the applied voltage was increased from 0 to 4 kV as a result of the smaller bubbles generated by ES. In addition, ES was shown to be more effective than the medium-pore-size($10{\sim}15{\mu}m$) bubble diffuser and the best results were achieved at low gas flow rates.

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.

Optical and Electrical Characteristics of GaN-based Blue LEDs after Low-current Stress (GaN계 청색 발광 다이오드에서 저전류 스트레스 후의 광 및 전기적 특성 변화)

  • Kim, Seohee;Yun, Joosun;Shin, Dong-Soo;Shim, Jong-In
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.2
    • /
    • pp.64-70
    • /
    • 2012
  • We analyzed the changes in electrical and optical characteristics of 1 $mm^2$ multiple-quantum-well (MQW) blue LEDs grown on a c-plane sapphire substrate after a stress test. Experiments were performed by injecting 50 mA current for 200 hours to TO-CAN packaged sample chips. We selected the value of injection current for stress through the junction-temperature measurement by using the forward-voltage characteristics of a diode to maintain a sufficiently low junction temperature during the test. The junction temperature at the selected injection current of 50 mA was 308 K. Experiments were performed under the assumption that the average junction temperature of 308 K did not affect the characteristics of the ohmic contact and the GaN-based materials. Before and after the stress test, we measured and analyzed current-voltage, light-current, light distribution on the LED surface, wavelength spectrum and relative external quantum efficiency (EQE). After the stress test, it was observed experimentally that the optical power and the relative EQE decreased. We theoretically investigated and experimentally proved that these phenomena are due to the increased nonradiative recombination rate caused by the increased defect density.

Effect of Ozone Concentration on AOP Efficiency of Secondary Effluent from Pig Slurry Purification System (오존 접촉농도가 양돈슬러리 2차 처리수의 고도처리 효율에 미치는 영향)

  • Jeong, K.H.;Jeon, S.K.;Ryu, S.H.;Kim, J.H.;Kwag, J.H.;Ann, H.K.;Jeong, M.S.;Yoo, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.181-188
    • /
    • 2011
  • With an increasing livestock population, animal manure production has been steadily increasing in Korea. This trend has forced farmers to spend more money for animal manure treatment in their farm. Therefore, research utilizing animal manure as a renewable resources has become increasingly important. The purpose of this study was to develop a stable advanced wastewater treatment system can be applied to conventional animal wastewater treatment processes and evaluate its contribution to reduce effluent discharge volume by recycling as flushing water. AOP (advanced oxidation process) process improved wastewater treatment efficiency in terms of color, suspended solids (SS) and chemical oxygen demand (COD). Due to the addition of Hydrogen peroxide ($H_2O_2$), pathogens, Salmonella and E. coli, reduction was accomplished. To enhance ozone treatment effect, three levels of ozone test on secondary effluent of pig slurry purification system were conducted. At the level of 5 g/hr, 6.7 g/hr and 8.4 g/hr color of secondary effluent of pig slurry purification system were decreased from 2,433 to 2,199, 2,433 to 1,980 and 2,433 to 243, respectively.

Somatic Embryo Germination and the Related Biochemical Changes of Liriodendron tulipifera by Bioreactor Immersion Time (생물반응기 내 침지시간에 따른 백합나무 체세포배 발아 및 생화학적 변화)

  • An, Chan-Hoon;Yi, Jae-Seon;Kim, Yong-Wook;Moon, Heung-Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.3
    • /
    • pp.423-431
    • /
    • 2010
  • To determine physical and physiological factors for Liriodendron tulipifera L. somatic embryo germination, temporary immersion bioreactor (TIB) system was investigated. It was designed to immerse liquid media with plantlets so that it was able to adjust the immersion time. Immersion of 120 minutes every 4 hours and 60 minutes every 4 hours was found to be effective in germination (91.64%, 85.67%, respectively). However, hyperhydricity of the plantlets was higher in short immersion time (15 minutes every 6 hours) and long immersion time (120 minutes every 4 hours) (51.61%, 34.28%, respectively). Immersion of 60 minutes every 4 hours showed the lowest hyperhydric plantlets, and also it showed the lowest activities of abscisic acid (ABA), superoxide dismutase (SOD), and catalase. The overall results implied that immersion time of media affected germination and growth of somatic embryo, and it was able to make use of germination and growth of L. tulipifera somatic embryos.

Interaction between Flexible Buried Pipe and Surface Load

  • Yoo, Chung-Sik;Chung, Suk-Won;Lee, Kwang-Myung;Kim, Joo-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.3
    • /
    • pp.83-97
    • /
    • 1999
  • This paper presents the results of a parametric study on the interaction between buried pipes and surface load using the finite element method of analysis. A series of laboratory model tests were also performed in order to validate the adopted finite element model and to capture essential features of the physical behavior of buried pipes subjected to surface load. In the parametric study, a wide range of boundary conditions were analyzed with emphasis on the response of the buried pipes to surface load. The results of analysis such as contact stress distribution at the soil/pipe interface and axial thrust of the pipe were thoroughly analyzed, and a database on the response of buried pipe under surface load was established for future development of a semi-empirical design/analysis method. The results indicated that the degree of interaction between buried pipes and surface load significantly varies with the vertical and lateral location of pipe with respect to surface load, and that the current design method, which does not consider soil-structure interaction, cannot correctly capture the pipe response to surface loading. Furthermore, based on the results of analysis, a semi-empirical equation was suggested, which estimates the maximum pipe thrust due to surface load for flexible buried pipes.

  • PDF

Double-layered Polymer Electrolyte Membrane based on Sulfonated Poly(aryl ether sulfone)s for Direct Methanol Fuel Cells (직접 메탄올 연료전지용 술폰화 폴리아릴에테르술폰 이중층 고분자 전해질 막의 제조 및 특성)

  • Hong, Young-Taik;Ko, Ha-Na;Park, Ji-Young;Choi, Jun-Kyu;Kim, Sang-Un;Kim, Hyung-Joong
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.291-301
    • /
    • 2009
  • Double-layered polymer electrolyte membranes were prepared from two different sulfonated poly(aryl ether sulfone) copolymers by the two-step solution casting method for direct methanol fuel cells (DMFC). Sulfonation degrees were adjusted 10% (SPAES-10) and 50% (SPAES-50) by controlling monomer ratios, and the weight ratios of SPAES-10 copolymer were varied in the range of 5~20% to investigate the effect of thickness of coating layers on the membranes. Proton conducting layers were fabricated from SPAES-50 solutions of N-methyl-2-pyrrolidone (NMP) by a solution casting technique, and coating layers formed on the semiliquid surface of the conducting layer by pouring of SPAES-10-NMP solutions onto. It was found that double-layered polymer electrolyte membrane could significantly reduce the methanol crossover through the membrane and maintain high proton conductivities being comparable to single-layered SPAES-50 membrane. The maximum power density of membrane-electrolyte assembly (MEA) at the condition of $60^{\circ}C$ and 2 M methanol-air was $134.01\;mW/cm^2$ for the membrane prepared in the 5 wt-% of SPAES-10 copolymer, and it was corresponding to the 105.5% of the performance of the commercial Nafion 115 membrane.

Removal of Volatile Organic Contaminant(toluene) from Specific Depth in Aquifer Using Selective Surfactant-Enhanced Air Sparging (계면활성제와 폭기를 이용한 대수층의 특정깊이에 존재히는 휘발성 유기오염물질 (톨루엔)의 휘발제거)

  • Song, Young-Su;Kwon, Han-Joon;Yang, Su-Kyeong;Kim, Heon-Ki
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.565-571
    • /
    • 2010
  • An innovative application of surfactant-enhanced air sparging(SEAS) technique was developed in this study. Using a laboratory-scale physical model packed with water-saturated sand, air sparging was implemented to remove water-dissolved toluene that was introduced into a specific depth of the system with finite vertical width prior to sparging. An anionic surfactant(Sodium dodecylbenzene sulfonate) was introduced into the contaminated layer as in dissolved form in the toluene-contaminated solution for SEAS, whereas no surfactant was applied in the control experiment. Due to the suppressed surface tension of water in the surfactant(and toluene)-containing region, the toluene removal rate increased significantly compared to those without surfactant. More than 70% of the dissolved toluene was removed from the contaminated layer for SEAS application while less than 20% of toluene was removed for the experiment without surfactant. Air intrusion into the contaminated layer during sparging was found to be more effective than that without surfactant, enhancing air contact with toluene-contaminated water, which resulted in improved volatilization of contaminant. This new method is expected to open a new option for remediation of VOC(volatile organic compound)-contaminated aquifer.