Jeong, Young Do;Kim, Jun Hyung;Lee, Suck Hong;Jeong, Jin Hoon
KSCE Journal of Civil and Environmental Engineering Research
/
v.31
no.3D
/
pp.421-431
/
2011
In this paper, actual bridges constructed with SMA (Stone Mastic Asphalt) deck pavement and virtual bridges substituted the deck pavement with polymer concrete under the same conditions were statically analyzed to investigate applicability of the thin polymer concrete bridge deck pavements. PSC (prestressed Concrete) girder bridge, steel box girder bridge, PSC box girder bridge, and RC (Reinforced Concrete) rahmen bridge constructed with the SMA deck pavement were analyzed and compared to evaluate various types of the bridge. The bridge deck and pavement were assumed to be fully bonded and the stress and deformation during the construction were ignored while those due to pavement weight and vehicle loading were analyzed. According to the analysis results, the stress and deformation of the bridges using the polymer concrete due to the pavement weight were smaller than those using the SMA because of smaller self weight due to lighter unit weight and thinner thickness of the pavement. The stress and deformation of the bridges using the polymer concrete due to the vehicle loading were larger than those using the SMA because of the smaller area moment of inertia due to the thinner pavement thickness. In case that the pavement weight and vehicle loading applied simultaneously, the stress and deformation of the bridges using the polymer concrete were smaller because effect of self weight reduction was more dominant. Investigation of performance of the bridge deck pavement and analysis of economical efficiency are warranted.
Proceedings of the Korean Society of Propulsion Engineers Conference
/
1997.11a
/
pp.35-36
/
1997
복합재는 강도가 높고 가볍기 때문에 최근 로켓의 연소관으로 널리 사용되고 있다. 그런데 이 복합재 로켓 연소관은 제조 후 대기 환경에 장기적으로 노출되어 있기 때문에 금속 연소관과는 달리 온도 또는 습도 등의 환경에 대한 영향을 고려해야 한다. 더구나 연소관은 내부에 추진제가 충전되어 있으므로 추진제의 기계적 특성이 습도에 민감함을 생각할 때 강도뿐만 아니라 습기의 투과도 또한 매우 중요한 고려 요소가 된다. 그러나 온/습도 변화에 따른 복합재 자체의 재료 특성 변화에 대한 연구는 많이 보고되었으나 습기의 투과 정도에 관한 연구는 자료가 미흡한 실정이다. 한편, 포화 함수율은 복합재에 따라서 차이가 있으나 T300/5208의 경우 문헌을 참조하면 20-$50^{\circ}C$에서 복합재 무게의 약 1.5% 정도이며 포화에 걸리는 시간은 약 100일 정도로 나타나 있다.본 연구에서는 수분이 복합재를 통하여 투과되는 정도를 고찰하기 위하여 $20^{\circ}C$,95%RH의 온/습도를 유지하는 수조를 제작하였고, 이 수조내에 보관한 복합재 연소관의 실린더 벽면으로 투과되는 습기를 측정하기 위하여 연소관 내에 습도 센서를 투입하여 상대습도를 직접 측정하였다. 복합재 연소관이 로켓에 사용될 때는 연소관 외부에 페인트로 피막 처리하고 연소관 내부에도 추진제와의 사이에 라이너가 접착되어 있어서 수분 침투 및 온도 등의 외부 환경조건에 견디기에 더 양호한 조건이나 본 연구에서는 복합재 자체의 특성을 고찰하기 위하여 섬유를 에폭시에 함침시켜 winding한 상태 그대로의 복합재 연소관 시료를 사용하였다. 습기의 투과는 내부에 라이너/인슐레이션이 피복되거나 또는 추진제가 충전된 경우 많은 감소효과를 보였다. 순수 복합재 연소관의 경우 수조에 넣고 평형에 도달한 후로부터 약 8개월의 습기 투과 상태를 볼대 벽면을 통하여 들어가는 water vapor flux는 $20^{\circ}C$,95%RH 에서 평균적으로 9.3163$\times$$10^{-8}$g/$m^2$sec로 나타났다. 이때 습기가 투과되는 연소관이 국지점을 평판으로 가정하고 Fick's law를 이용하여 구한 습기에 대한 복합재의 확산계수는 D=2.5$\times$$10^{-6}$$mm^2$sec였으며, 이는 다른 graphite/epixy 복합재의 확산계수와 유사한 값을 나타내고 있다. 또한 추진제가 충전된 연소관을 절단하여 밀폐한 후 95%RH 습도 조건에 보관함으로써 연소관 내부의 추진제 기계적 특성에 미치는 침투된 습기의 영향도 함께 고찰하였다. 추진제에 따라 차이는 있겠으나 추진제가 충전된 연소관은 순수 복합재 연소관에 비해 습기의 투과 정도가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.
Medium-density fiberboard (MDF) is widely used as an indoor building materials. However, formaldehyde resins, commonly used to bind MDF together, emit formaldehyde and other volatile organic compounds that cause health risk at sufficient concentration. In this study, condensed tannin having formaldehyde absorption ability was used to solve the problem of formaldehyde emission generated from surface material. The synthesis of melamine-formaldehyde resin and reaction of melamine-formaldehyde and condensed tannin were analyzed by FT-IR spectrum. Also surface properties, such as shear force, impact strength, tape adhesion, pencil hardness and gloss retention were measured. Free formaldehyde analysis was performed to analyze remaining unreacted formaldehyde. According to the results, the optimum shear force and impact strength could be obtained by 10 wt.% usage of condensed tannin. In cases of pencil hardness and gloss retention, the optimum properties could be obtained at 20 wt.% of condensed tannin. The amounts of formaldehyde emission of surface material containing 20 wt.% of condensed tannin was 59 ${\mu}g/m^2{\cdot}h$. The amounts of formaldehyde emission could be reduced 3 times by using 20 wt.% of condensed tannin.
Journal of the Microelectronics and Packaging Society
/
v.24
no.2
/
pp.11-15
/
2017
As the heat dissipation problem is increased in 3D multi flip chip packages, an improvement of thermal conductivity in bonding interfaces is required. In this study, the effect of alumina filler addition was investigated in non-conductive paste(NCP). The fine alumina filler having average particles size of 400 nm for the fine pitch interconnection was used. As the alumina filler content was increased from 0 to 60 wt%, the thermal conductivity of the cured product was increased up to 0.654 W/mK at 60 wt%. It was higher value than 0.501 W/mK which was reported for the same amount of silica. It was also found out that the addition of fine sized alumina filler resulted in the smaller decrease in thermal conductivity than the larger sized particles. The viscosity of NCP with alumina addition was increased sharply at the level of 40 wt%. It was due to the increase of the interaction between the filler particles according to the finer particle size. In order to achieve the appropriate viscosity and excellent thermal conductivity with fine alumina fillers, the highly efficient dispersion process was considered to be important.
Egg development and early life history of the Korean natural monument fish Hemibarbus mylodon (Pisces: Cyprinidae) were investigated to provide basic data on biological characteristics and ecological recovery. Adult fish were collected from nature and transferred to the laboratory. For the first time, artificial maturation of females and males succeeded after 15 months of indoor culture. Mature eggs and sperm were obtained using Ovaprim injections (0.5 mL/kg) and then the eggs were fertilized using the dry method in the laboratory. The mature eggs were adhesive, turbid, and greyish; they averaged $2.21{\pm}0.06mm$ (n=30) in diameter. The embryos began to hatch about 78 h after fertilization at a water temperature $20{\pm}1^{\circ}C$, and the newly-hatched larvae were $6.6{\pm}0.75mm$ in total length (TL). At 14 days after hatching, the post-larval individuals were $13.5{\pm}0.23mm$ (TL), and their yolk sacs were completely absorbed. Twenty one days after hatching, they entered the juvenile stage and reached $13.5{\pm}0.23mm$ (TL). At 100 days after hatching, their band patterns, external form, and a pair of barbels were similar to those of adults, and they averaged $33.0{\pm}4.25mm$ (TL). The breeding technology and characteristics of early life history obtained in this study will be very helpful for conservation of H. mylodon in nature.
Purpose: The purpose of this study was to evaluate the efficacy and substitute possibility of a newly developed flowable composite resins as a luting cement for translucent fiber post. Material & Method: Two kinds of 12 mm translucent fiber Post (D.T. Light-Post (Bisco, USA) and FRC Postec (Ivoclar vivadent, Liechtenstein) was inserted into the teflon mold (7 mm diameter, 9 mm long) and Filtek-Flow (3M ESPE. USA), a light activated flowable composite resin, was polymerized for 60 seconds through the post. Also, the post was cut from the tip to 9 mm, 6 mm, 3 mm, and Filtek-Flow was light cured according to each length. For comparison, 60 seconds light-cured and 24 hours self-cured two dual cured resin cement (Duo-cement (Bisco, USA) and 2 Panavia-F (Kuraray, Japan)) samples were prepared as control group. Also cavities (1 mm in width, 1 mm in depth and 12 mm in length) were prepared using acrylic plate and aluminum bar, and flowable composite resin was flied and light cured by the diffused light from the fiber post's side wall. The degree of polymerization was measured according to the distance from curing light using Vickers' hardness test. Result: Within the limitation of this study, the following conclusions were drawn: 1. Vickers' hardness of light cured dual cured resin cement and flowable composite resin decreased from Panavia-F, Filtek-Flow and Duo-cement accordingly (p<0.05). In the dual curing resin cement, light curing performed group showed higher surface hardness value than self cured only group (p<0.05). 2. Surface hardness ratio (light cured through fiber post /directly light cured) of D.T. Light-Post using Filtek-Flow showed about 70% in the 6 mm deep and about 50% in the 12 mm deep FRC Postec showed only 40% of surface hardness ratio. 3. Surface hardness ratio by diffused light from the post's side wall showed about 50% at 6 mm and 9 mm deep, and about 40% at 12 mm deep in D.T. Light-Post. However, FRC Postec showed about 40% at 6 mm deep, and almost no polymerization in 9 mm and 12 mm deep.
The purpose of this study was to assess the marginal fit of three-unit bridges produced using LAVA CAD/CAM (computer-aided design/computer-aided manufacturing) system and conventional PFG in vitro. Materials and methods: #11, 13 resin teeth were prepared on dentiform, then duplicated. Twenty resin models were fabricated, ten for PFG 3-unit bridges and ten for LAVA 3-unit bridges. Each bridge was cemented on the resin model. Marginal discrepancy was measured with stereoscopic microscope (Nikon DS-Fi 1, Nikon, Japan) at a magnification of ${\times}75$. Independent t-test was done for the statistical analysis. Results: The mean marginal discrepancy values and standard deviations of the PFG bridges was $97.1{\pm}18.7\;{\mu}m$ for incisors, $76.6{\pm}21.8\;{\mu}m$ for canines; that of the LAVA bridges was $90.4{\pm}26.7\;{\mu}m$ for incisor, $110.2{\pm}30.2\;{\mu}m$ for canines. The mean marginal discrepancy between PFG and LAVA for incisor did not show significant difference (P<.05). But for canine, the mean marginal discrepancy of PFG bridges was smaller than that of LAVA bridges (P<.05). Conclusion: The LAVA CAD/CAM 3-unit bridges and the PFG 3-unit bridges showed clinically acceptable marginal discrepancy.
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.4
/
pp.553-565
/
2001
One-bottle adhesive system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. To test the shear bond strength of a new "one-bottle adhesive" system to bovine dentin various commercially available one-bottle adhesives(Prime & Bond $2.1^{(R)}$, One Coat $Bond^{(R)}$, Syntac $Sprint^{(R)}$, Single $Bond^{(R)}$) were included for comparison. And we observe the interfacial morphology by scanning electron microscope. The results were as follows; 1. Group II (One Coat $Bond^{(R)}$) showed higher shear bond strength than group I (Prime & Bond $2.1^{(R)}$), group III(Syntac $Sprint^{(R)}$), and group IV(Single $Bond^{(R)}$), but no statistically significant difference was founded between groups(p>.05). 2. Relating reverse-cone shape resin tags were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. But, we observed in group III rare lateral branched than other three groups, and discontinuous hybrid layer.
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.4
/
pp.566-574
/
2001
For decades it has been a clinically accepted requirement, in case of salivary contamination, to re-etch conditioned enamel and dentin to proceed with the adhesive technique. Only a few reports have been so far dealing with the potential of one-bottle adhesive system to bond even when applied after salivary contamination and without re-etching. The purpose of this study was to evaluate the influence of the salivary contamination on the shear bond strength of dentin. The results were as follows: 1. In group II, in which saliva contamination and washing occurred before applying of Prime & Bond NT showed high shear bond strength as in control group. In Group III and IV, in which the cured adhesive was contaminated with saliva, showed significantly lower mean bond strength, 2. Relating long resin tags of $70\sim120{\mu}m$ were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. And there were no differences between groups.
Kim, Hyungjun;Park, Soyoung;Jeong, Taesung;Kim, Shin
Journal of the korean academy of Pediatric Dentistry
/
v.46
no.4
/
pp.382-391
/
2019
This study was aimed to assess the new trial for minimal cavity preparation in composite restoration combined with resin infiltration, focusing at application sequence. 32 human primary molars with early carious lesions around small cavity were selected and randomly divided into two groups, according to the sequence of cavity preparation (P), composite filling (F) and resin infiltration (I) as IPF and PFI group. Each group was assessed about amount of tooth reduction, features of resin infiltration, and marginal leakage around restoration. Amount of tooth reduction evaluated using micro-CT was decreased compared with the original lesion size in both groups. Features of resin infiltration were verified under confocal laser scanning microscopy. In both groups, infiltrant resin was found on all around the composite and maintained in spite of extent of decalcification even after artificial caries induction. Marginal micro leakage assessed with silver nitrate immersion and micro-CT was found more frequently in PFI group. The technique combining resin infiltration and composite restoration might ensure better adhesion prognosis as applied by the sequence of resin infiltration, cavity preparation, and composite filling. This new trial was thought meaningful in minimizing the cavity size and contributing to minimal invasive dentistry.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.