• Title/Summary/Keyword: 접착방법

Search Result 614, Processing Time 0.034 seconds

Evaluation of Dispersivity and Resistance of the Adhesive Joint According to Dispersion Methods of CNT (CNT 분산 방법에 따른 접착조인트의 저항 및 분산성 평가)

  • Lee, Bong-Nam;Kim, Cheol-Hwan;Kweon, Jin-Hwe;Choi, Jin-Ho
    • Composites Research
    • /
    • v.28 no.6
    • /
    • pp.348-355
    • /
    • 2015
  • NDT (Non Destructive Test) of the adhesive joints is very important because their strengths have greatly affected by the worker's skill and environmental condition. Recently, the electric impedance method in which 1-2 wt% CNT was dispersed in the adhesive and the electric resistance of the adhesive joint was measured was suggested for the defect detection of the adhesive joint. The uniform dispersion of CNT in the electric impedance method is very important to make a constant electric resistance of the adhesive joint and the accuracy of defect detection depends on the uniform dispersion. In this paper, the adhesive joints in which CNT was dispersed in the adhesive by the four dispersion methods were made and their electric resistance were measured. The pre-process and evaporation process of CNT using the ultrasonic method and agitation method was used and the effective dispersion method was suggested. Also, the criteria to evaluate the dispersivity was proposed.

Debonding Detection Techniques of FRP/Rubber Interface by the Ultrasonic Phase Reversal (초음파 위상 반전에 의한 FRP/고무 접착계면의 미접착 결함 검출 연구)

  • Kim Dong-Ryun;Chung Sang-Ki;Lee Sang-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.11-16
    • /
    • 2006
  • The object of this study is to develop new examination techniques for detecting the debonds in adhesive interface of different kinds of the material. Ultrasonic signal was modeled by theoretically analyzing ultrasonic propagation phenomenon of the adhesive interface and debonding interface. The test method using the phase reversal of the debonding interface applied to the FRP/Rubber test block. Aluminum/Rubber test block with the flat bottom hole was manufactured to quantitatively evaluate the minimum detection ability of the defects. The pulse echo reflection method and the phase reversal method were mutually compared and it was estimated that the phase reversal method could detect the debonds on the basis of the theoretically predicted ultrasonic signal and ultrasonic test data.

  • PDF

A Debonding Detection Technique for FRP/Rubber Interface by Ultrasonic Phase Reversal (초음파 위상 반전에 의한 FRP/고무 접착 계면의 미접착 결함 검출 연구)

  • Kim, Dong-Ryun;Lim, Soo-Yong;Chung, Sang-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.2
    • /
    • pp.9-16
    • /
    • 2009
  • The object of this study is to develop new examination technique for detecting debond in adhesive interface of different kinds of materials. Ultrasonic signal was modeled by theoretically analyzing ultrasonic propagation phenomenon of the adhesive interface and debonding interface. The test method using the phase reversal of the debonding interface applied to the FRP/Rubber test block. Aluminum/Rubber test block with the flat bottom hole was manufactured to evaluate quantitatively the minimum detection ability of defects. The pulse echo reflection method and the phase reversal method were mutually compared and it was estimated that the phase reversal method could detect the debond on the basis of the theoretically predicted ultrasonic signal and ultrasonic test data.

A comparative study on bond strength and adhesive failure pattern in bracket bonding with self-etching primer (Self-etching Primer를 이용한 교정용 브라켓 부착시 전단결합강도와 파절양상에 관한 비교연구)

  • Kim, You-Kyoung;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.325-332
    • /
    • 2004
  • A self-etching primer that combines the etchant and primer in one chemical compound saves time and should be mote cost-effective to the clinician and patient. The purpose of this study was to evaluate the clinical effectiveness of a self-etching primer by measuring shear bond strengths according to various conditions and observing adhesive failure patterns. For this Investigation, 120 upper and lower premolars extracted for orthodontic purposes were used and randomly divided into six groups of twenty teeth each. Human premolars were embedded in a metal cylinder with orthodontic resin. Metal brackets and ceramic brackets were bonded with XT primer and self-etching primer by means of XT adhesive. Upon curing, plasma arc light and visible light were used. After bonding, the shear bond strength was tested by Instron universal testing machine, and the amount of residual adhesive that remained on the tooth after debonding was measured by stereoscope and assessed with an adhesive remnant index. The results were as fellows: 1. When brackets were bonded, if other conditions remained the same, there was no significant difference in shear bond strength due to the type of primer - either self-etching primer or XT primer. 2. When metal brackets were bonded, there was no significant difference in shear bond strength according to the source of light - plasma arc light or visible light - and type of primer. 3. There was a very significant difference in shear bond strength according to the type of brackets - metal or ceramic brackets. The shear bond strength of ceramic brackets was stronger than metal brackets. 4. When the adhesive failure patterns of metal brackets bonded with self-etching primer were observed by using the adhesive remnant index, the bond failure of the metal bracket occurred more frequently at the bracket-adhesive. The failure of the ceramic bracket, however, occurred more frequently at the enamel-adhesive interface. The adhesive failure patterns of metal brackets bonded with XT primer observed the same patterns. The above results suggest that self-etching primer can be clinically useful for bonding the brackets without fear of a decrease in shear bond strength.

Measuring Method of Formaldehyde Emission for Plywood (합판의 포름알데히드방산량 측정방법)

  • Lee, Sang-Min;Park, Jong-Young;Kang, Eun-Chang;Kim, Su-Woun;Han, Seung-Tak
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.11-16
    • /
    • 2010
  • Unlike other composites boards such as fiberboard and particleboard, plywood is manufactured with sheets of veneers. When the plywood manufactured, the adhesive is spreaded through gluelines on each surface of veneers. For that reason, formaldehyde emission of plywood can be considered as different way. Therefore, this research was conducted to understand the formaldehyde emission pattern of plywood. To measure formaldehyde emission, four different specimen preparing methods were used. The test specimen taken by a total surface area, a given number and a total side area showed inconsistent results. On the other hand, the result of formaldehyde emission showed consistency when considered only the length of adhesive layers.

Measurement of Adhesion (접착력의 측정)

  • Kim, Sung-Ryong;Lee, Ho-Young
    • Journal of Adhesion and Interface
    • /
    • v.4 no.3
    • /
    • pp.21-32
    • /
    • 2003
  • Various methods for adhesion measurement, which are related to previously published paper [J. of Soc. of Adhe. and Inter, 3,4 (2002)], are reviewed. At first, the prerequisite for the ideal adhesion strength measurement is considered, and three categories of methods for adhesion measurement, such as mechanical, non-mechanical methods and miscellaneous methods, are introduced.

  • PDF

특집:자연모사 그린테크놀로지 - 자연모사 바이오 접착 패치 개발

  • Kim, Jeong-Hun;Seo, Gap-Yang
    • 기계와재료
    • /
    • v.23 no.4
    • /
    • pp.16-25
    • /
    • 2011
  • 본고는 자연모사공학에서 출발하여, 자연계에 존재하는 건식 접착 성질을 이용하기 위한 방법으로서 게코도마뱀의 발바닥 섬모 구조를 모사하기 위한 방안들을 설명하고 그 응용분야를 전망한다. 도마뱀의 섬모 구조가 가지는 네 가지 특징들은 고분자 폴리머 재료와 나노 신장 기술, 2단계 UV 자외선 성형 기술, 전자빔 조사 등과 같은 기술을 통해 구조 및 기능의 모사가 가능하고 실제로 제작된 구조는 좋은 접착 특성을 나타냄을 알 수 있었다. 이를 토대로 다양한 섬모 구조에서의 접착 성능을 분석하고 실제 생활에서 바이오 패치로의 응용 가능성을 제시하였다.

  • PDF

Photovoltaic performance evaluation of the bonded single crystalline silicon solar cell on composite specimens under mechanical loading (기계적 하중 하에서 복합재료 시험편에 접착된 단결정 실리콘태양전지의 성능평가)

  • Kim, Jong-Cheon;Choi, Ik-Hyeon;Kim, Dae-Hyun;Jeong, Seong-Kyun
    • Composites Research
    • /
    • v.24 no.6
    • /
    • pp.56-63
    • /
    • 2011
  • The objective of this study is to investigate appropriate bonding methods of solar cells in order to apply solar cells, which have been receiving particular attention as a renewable energy due to fossil energy depletion and environment issues, to composite structures. Back-contact solar cells with approximately 24.2% energy conversion efficiency were used in this study. Since silicon-based solar cells are mechanically fragile, the secondary-bonding methods using adhesive were examined in this study. The experiment was conducted with three kinds of bonding materials such as EVA film, Resin film and elastic adhesive. The performance of solar cells for three types of adhesives under mechanical loading on test specimens is conducted. In addition, the measuring equipment was designed to evaluate the performance of the solar cells under mechanical loading in real time and the fracture characteristics depending on bonding materials were evaluated. The reason decreasing solar cells efficiency were analyzed and considered by Fractography. The results show that the solar cell performance is largely affected by bonding techniques. Moreover, the bonding method using elastic adhesive shows best solar cell efficiency.