• Title/Summary/Keyword: 점프동작

Search Result 38, Processing Time 0.019 seconds

Analysis of Kinematic on Ring jump in the Rhythmic Sport Gymnastics (리듬체조 Ring jump동작의 운동학적 분석)

  • Woo, Byung-Hoon;In, Hee-Kyo;Lee, Kae-San
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.65-75
    • /
    • 2002
  • The study has a goal that produces abundant documents that needed for athletes to teach and progress skills by analyzing 3-dimensional action analysis of C-difficulties Ring jump included in body original elements among techniques constructing Rhythmic Sport Gymnastics. 1. It was the longest applied time delay that E-3 indicates 0.409${\pm}$0.017sec in each event applied time delay. 2. It was the tallest height that E-3 indicates 88.5${\pm}$1.3% in displacement of body's center. 3. It was the fastest velocity in E-2 where the velocity of left foot is 732.4${\pm}$46.1cm/sec, the velocity of right foot is 1958.4${\pm}$25.1cm/sec. 4. the lowest angle was founded at 97.8 degree in the E-3 on the trunk extension angle. 5. The lowest angle of both sides were seen at 92.8${\pm}$14.9degree and 69.2${\pm}$5.7degree in the E-3 on the each displacement of knee joint. 6. The highest angle of both sides were seen at 171.3${\pm}$6.9degree and 167.9${\pm}$8.4degree in the E-3 on the each displacement of ankle joint As a result of these studies, by jumping with ankle joint extension to accomplish the Ring jump action, it is considered to have the time of flexiblity and staying in the air which we can see in a back.

Biomechanical Analysis of Lower Extremity Joints According to Landing Types during Maximum Vertical Jump after Jump Landing in Youth Sports Athletes (유소년 스포츠 선수들의 점프착지 후 수직점프 동작 시 착지 유형에 따른 하지관절의 운동역학적 분석)

  • Jiho Park;Joo Nyeon Kim;Sukhoon Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.3
    • /
    • pp.110-117
    • /
    • 2023
  • Objective: The purpose of this study was to find out kinematic and kinetic differences the lower extremity joint according to the landing type during vertical jump movement after jump landing, and to present an efficient landing method to reduce the incidence of injury in youth players. Method: Total of 24 Youth players under Korean Sport and Olympic Committee, who used either heel contact landing (HCG) or toe contact landing (TCG) participated in this study (HCG (12): CG height: 168.7 ± 9.7 cm, weight: 60.9 ± 11.6 kg, age: 14.1 ± 0.9 yrs., career: 4.3 ± 2.9 yrs., TCG height: 174.8 ± 4.9 cm, weight: 66.9 ± 9.9 kg, age 13.9 ± 0.8 yrs., career: 4.7 ± 2.0 yrs.). Participants were asked to perform jump landing consecutively followed by vertical jump. A 3-dimensional motion analysis with 19 infrared cameras and 2 force plates was performed in this study. To find out the significance between two landing styles independent t-test was performed and significance level was set at .05. Results: HCG showed a significantly higher dorsi flexion, extension and flexion angle at ankle, knee and hip joints, respectively compared with those of TCG (p<.05). Also, HCG revealed reduced RoM at ankle joint while it showed increased RoM at knee joint compared to TCG (p<.05). In addition, HGC showed greater peak force, a loading rate, and impulse than those of TCG (p<.05). Finally, greater planta flexion moment was revealed in TCG compared to HCG at ankle joint. For the knee joint HCG showed extension and flexion moment in E1 and E2, respectively, while TCG showed opposite results. Conclusion: Compared to toe contact landing, the heel contact landing is not expected to have an advantage in terms of absorbing and dispersing the impact of contact with the ground to the joint. If these movements continuously used, performance may deteriorate, including injuries, so it is believed that education on safe landing methods is needed for young athletes whose musculoskeletal growth is not fully mature.

The Effect of Badminton Shoe Forefoot Flexibility during the Under Clear Quick Lunge from a Jump Smashing (배드민턴화의 굴곡성(Flexibility) 차이가 점프 스매싱 후 언더클리어 동작시 하지에 미치는 영향)

  • Yi, Jae-Hoon;Sohn, Jee-Hoon;Ryue, Jae-Jin;Lee, Ki-Kwang;Lee, Jung-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.105-111
    • /
    • 2012
  • The purpose of this study was to investigate the effect that difference in forefoot of shoe flexibility during the quick lunge from a jump smashing on the lower limbs and the plantar pressure distribution. For this 10 elite badminton players with over 10 years experience and right handed participated. Two kinds of badminton shoes were selected and tested mechanical testing for the forefoot flexibility. Motion analysis, ground reaction forces and plantar pressure distribution were recorded. It was required to conduct lunge movement after jumping smashing as possible as high. Photo sensor was located in 3 meter away from standing position and its height was 40 cm. Subjects were conducted to return original position after touching the sensor as under clear movement as possible as fast. Forefoot stiffness had an effect on shoe peak bending degree and peak bending angular velocity in propulsion phase. Forefoot flexibility had an effect on ankle plantar flexion and knee flexion moment. It appears that joint power on lower limb and peak plantar pressure were not influenced by the flexibility of shoes.

Difference in Lower Extremity Landing Biomechanics between Male and Female Ballet Dancers During the Box Drop Landing (박스 드롭 착지 시 남자와 여자 발레 무용수들의 하지의 생체역학적 요인의 차이)

  • Choi, In-Ae;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.647-653
    • /
    • 2009
  • The purpose of this study was to investigate the differences between female and male ballet dancers in anterior cruciate ligament injury risk factors during the box drop landing task. Nine female and nine male collegiate ballet dancers participated in this study. Kinematic and ground reaction data were collected and combined with inverse dynamics to estimate the knee extensor and abductor moment. EMG data from the biceps femoris and rectus femoris were used to estimate the ratio of quadriceps-hamstrings muscle activity. No gender differences in anterior cruciate ligament injury risk factors were found during the box drop landing task. A significant relationship was found between female and male ballet dancers in the knee flexion angle.

Design and Implementation of a Single-Chip 8-Bit Microcontroller (단일 칩 8비트 마이크로컨트롤러의 설계 및 구현)

  • Ahn, Jung-Il;Park, Sung-Hwan;Kwon, Sung-Jae
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.4
    • /
    • pp.72-81
    • /
    • 2006
  • In this paper, we first define a total of 64 instructions that are considered to be essential and frequently used, construct a datapath diagram, determine the control sequence using a finite state machine, and implement an 8-bit microcontroller using FPGA in VHDL. In the past, only functional simulation results of a rudimentary microcontroller were reported, the microcontroller lacked interrupt handling capability, or it was not implemented in hardware. We have designed a self-contained 8-bit microcontroller such that it can perform data transfer, addition, and logical operations, as well as stack and external interrupt operations. Following timing simulation of the designed microcontroller, we implemented it in an FPGA and verified its operation successfully. The design and implementation has been done under the Altera MAX+PLUS II integrated development environment using the EP1K50TC144-3 chip. The maximum operating frequency, the total number of logic elements used, and the logic utilization were found to be 9.39 MHz, 2813, and 97%, respectively. The result can be used as a microcontroller IP, and as needs arise, the VHDL code can be modified accordingly.

  • PDF

A Comparison analysis of kinematics of lower extremities for 1st position jump in ballet between two types of ballet shoes (발레의 1st Position 점프 동작 시 신발 유형에 따른 하지의 운동학적 비교분석)

  • Youm, Chang-Hong;Park, Young-Hoon;Seo, Kook-Woong
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.327-340
    • /
    • 2003
  • The purpose of this study was to investigate the height of jump, angle of the ankle and knee, the angular velocity of the ankle and knee between two types of ballet shoes during a jump in the 1st position. The subjects were 5 female ballet majors of university in Busan the majors who have been dancing ballet for six years on the average. The conclusions are as follows: 1. The height of jump had no significant difference between two types of ballet shoes, and then the average of the height of jump with point shoes group ($20.24{\pm}4.62\;cm$) was a little higher than ballet shoes group ($17.50{\pm}4.05\;cm$). 2. The angle of the ankle had no significant difference for all events between two types of ballet shoes. The minimum angle of ankle joint was represented to $54.36_{\circ}$ at the E1 of the left ankle angle of the ballet shoes and the maximum value was showed $155.43_{\circ}$ at the E3 of the right ankle angle of the point shoes. 3. The angle of the knee had no significant difference for all events between two types of ballet shoes. The minimum angle of knee joint was represented to $99.54_{\circ}$ at the E1 of the left knee angle of the ballet shoes and the maximum value was showed $174.25_{\circ}$ at the E3 of the right knee angle of the point shoes. 4. The ankle velocity of the ankle had no significant difference for all events between two types of ballet shoes. The minimum angular velocity of the ankle was represented to 4.35 deg/s at the maximum height(E3) of the point shoes and the maximum value was showed 597.81 deg/s at the take-off(E2) of the right ankle angle of the point shoes. 5. The angular velocity of the knee had significant difference between two types of ballet shoes at the event 1(p<.05). The minimum angular velocity of the hee was represented to -1.68 deg/s at the maximum height(E3) of the point shoes and the maximum value was showed 360.25 deg/s at the take-off(E2) of the left knee angle of the ballet shoes. The other events had no significant difference between two types of ballet shoes.

Mechanical Analysis of the Force on Landing 3 Type Curves(Ellipse, Circle, Brachistochrone) of Halfpipe (스노우보드 하프파이프 점프시 착지 충격에 관한 3가지 곡선(타원, 원, 브라키스토크론)의 역학적 해석)

  • Lee, Un-Hak;Kim, Kew-Wan;Park, In-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.1-19
    • /
    • 2008
  • This research is to analyze the force on landing 3 Type of Halfpipe Curves(Ellipse, Circle, Brachistochrone) based on the mechanical calculation of normal force on a sloping surface. Jumping off a platform on a bard horizontal surface, the flexing of the legs, the softness of the snow, the angle of the landing surface, initial velocity and the forward motion of the snowboarder can contribute to reducing the force on landing. But halfpipe is significantly determined by the curvature of surface. It is definitely verified that the Brachistochrone curve is more safety than others. However currently using the Ellipse curve is mostly safe too. If we consider the efficiency of construction, we can easily think there is no use of another curves except normal ellipse curved halfpipe. It would better that geometrically verity curved halfpipe should be designed for improving fluent skills to snowboarders. This methode of research can be a model of scientifical research on sports safety how can sportsman reduce critical injury by designing optimal halfpipe facilities and manual.

Development of an EEG Software for Two-Channel Cerebral Function Monitoring System (2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발)

  • Kim, Dong-Jun;Yu, Seon-Guk;Kim, Seon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • This paper describes an EEG(electroencephalogram) software for two-channel cerebral function monitoring system to detect the cerebral ischemia. In the software, two-channel bipolar analog EEG signals are digitized and from the signals various EEG parameters are extracted and displayed on a monitor in real-time. Digitized EEG signal is transformed by FFT(Fast Fourier transform) and represented as CSA(compressed spectral array) and DSA(density spectral array). Additional 5 parameters, such as alpha ratio, percent delta, spectral edge frequency, total power, and difference in total power, are estimated using the FFT spectra. All of these are effectively merged in a monitor and displayed in real-time. Through animal experiments and clinical trials on men, the software is modified and enhanced. Since the software provides raw EEG, CSA, DSA, simultaneously with additional 5 parameters in a monitor, it is possible to observe patients multilaterally. For easy comparison of patient's status, reference patterns of CSA, DSA can be captured and displayed on top of the monitor. And user can mark events of surgical operation and patient's conditions on the software, this allow him jump to the points of events directly, when reviewing the recorded EEG file afterwards. Other functions, such as forward/backward jump, gain control, file management are equipped and these are operated by simple mouse click. Clinical tests in a university hospital show that the software responds accurately according to the conditions of patients and medical doctors can use the software easily.

  • PDF