• Title/Summary/Keyword: 점재

Search Result 14, Processing Time 0.019 seconds

A Study on Applicability of Tensile Constitutive Model of Steel Fiber Reinforced Concrete in Model Code 2010 (Model Code 2010에 제시된 강섬유 보강 콘크리트의 인장 구성모델 적용성 고찰)

  • Yeo, Dong-Jin;Kang, Duk-Man;Lee, Myung-Seok;Moon, Do-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.581-592
    • /
    • 2016
  • Tensile constitutive stress-strain model of steel fiber reinforced concrete (SFRC) in fib MC2010 was investigated. In order to model tensile behavior of SFRC, three point loading flexural tests were conducted on notched small beams according to BE-EN-14651. Design parameters for the constitutive model were determined from the flexural tests. Flexural test and finite element analysis were conducted on large SFRC beam without steel reinforcements and compared with each other. In addition, parametric study on the effect of compressive and tensile model, and characteristic length on flexural behavior of the SFRC beam was conducted also. In results, pre-peak load-displacement curves from the FE analysis was close to experimental curves but significant difference was shown in post-peak behavior. The reason of the difference is originated from the fact that the fiber distribution and orientation were not being properly considered in the MC2010 model. This study shows that modification and detail explanations on the orientation factor K in MC2010 might require to better reproduce the behaviour of large scale SFRC beams.

The Point Load Index of the Daegu Shale and its Relation to the Uniaxial Compressive Strength (대구지역 셰일의 점재하지수 특성 및 일축압축강도와의 상관성)

  • Lee, Younghuy;Youn, Chanho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.37-45
    • /
    • 2009
  • The experimental study was carried out to evaluate the characteristics of the point load index and the uniaxial compressive strength of inherently anisotropic shale in the laboratory. In the testing program the effects of size and the shape on the point load index were investigated both in the axial and diametral direction. In general, the point load index of the shale was constant when the length/diameter (L/D) ratio of the specimen is greater than 1.0 in the diametral direction. The point load index in axial direction shows slight decrease as the L/D ratio is increased and the corner breakage was observed when L/D ratio is greater than unity. The minimum point load index was observed in the bedding angle of $\beta=15^{\circ}{\sim}30^{\circ}$ in the axial point load tests and of $\beta=30^{\circ}$ in the uniaxial compression tests. The relationship between the point load index and the uniaxial compressive strength was linear to ${\sigma}_c=25.0 I_{s(50)}$ for the specimen with the bedding plane angle, $\beta$ at the range of $0^{\circ}{\sim}90^{\circ}$. On the other hand, this relationship was appeared linear to ${\sigma}_c=14.4 I_{s(50)}$ when the bedding angle, $\beta$ is fixed to 90${^{\circ}}$ and this correlation is much different from ${\sigma}c=22 I_{s(50)}, which is generally applied to the rock specimen with no bedding plane in ISRM (1985). The anisotropic strength with different $\beta$ angle shows the shoulder type and this can be suitably modelled by the corrected Ramamurthy'(1993)s equation with the index value of 'n' equal to 3.0.

  • PDF

Petrological Characteristics and Provenance Interpretation of Daejiguksatapbi (State Preceptor Daeji's Memorial Stele) in Samcheonsaji Temple Site, Seoul (서울 삼천사지 대지국사탑비의 암석학적 특성과 산지해석)

  • Kim, Jiyoung;Lee, Myeong Seong;Lee, Chan Hee
    • Economic and Environmental Geology
    • /
    • v.46 no.2
    • /
    • pp.93-104
    • /
    • 2013
  • Daejiguksaptapbi (Tapbi) is a memorial stele which is inscribed with personal history of a state preceptor, Daejiguksa Beopkyeong. The Tapbi comprises tortoise-shaped pedestal, dragon top and body stone, and the body stone is remained in 255 pieces by excavation in Samcheonsaji temple site of Seoul. The Tapbi is composed of tuffaceous breccia for the body, coarse-grained pink feldspar granite for the pedestal and fine-grained granite for the top. As a result of geological survey to find a rock provenance of the Tapbi rock, the tuffaceous breccia is found in the banks of Gangwha straits, and the pink feldspar granite and fine-grained granite are found around the temple site in Mt. Bukhansan. Each rock shows similarities to the Tapbi in lithology and mineralogy. Also, geochemical data of major, some trace and rare earth elements verify their cognation in each rock type. It can be interpreted that the provenance of the body stone is distant as Gangwha area, and the provenance of the pedestal and top stones are near the temple site. The results can be utilized to restore the Tapbi by using the same rocks.

Continuity for Double Tee Slabs (더블티 슬래브의 연속화)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.99-106
    • /
    • 2001
  • The main objective of this study is to develop a continuity of double tee slab with two modified dap-ends to solve the problems of excessive moment, slab depth, deflection, and joint cracking in the original simply supported double tee slab systems. The modified joint is produced in a combination with two slabs with modified dap and one rectangular beam. The modified joint can be justified as following different merits. The span capacity for a design load is increased, while the deflection of the slab is decreased due to the decrease of positive moment at the center span of the slab. The joint cracking between slab and beam, which occur frequently in the original slab systems of double tee will be reduced. No more additional form work is needed to cast topping concrete for continuity. Three point loading tests are performed on the specimens with a variable of an amount of main longitudinal reinforcement to evaluate flexural and shear behavior. Following conclusions are obtained from the experimental investigation. The continuity of double tee slab effectively is provided by placing longitudinal steel reinforcement in the topping concrete over the connection, and generally leads to an increase in span capacity of double tee slabs with reduced deflection. It is more effective to control the initial cracking at the connection than that of some simply supported double tee slab systems.