An Assessment of Friction Factor and Viscosity Models for Predicting the Refrigerant Characteristics in Adiabatic Capillary Tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Lee, Sung-Hong;Kim, Lyun-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.140-148
    • /
    • 2009
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses and flashing simultaneously. In this paper flow characteristics of adiabatic capillary tubes were simulated with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models. The predicted pressure distribution and mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing suitable correlations of friction factor, two-phase viscosity and two-phase frictional multiplier.

An assessment of friction factor and viscosity models for predicting the refrigerant characteristics in adiabatic capillary tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Kim, Lyun-Su
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.47-54
    • /
    • 2008
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses, and flashing, simultaneously. In this paper flow characteristics of adiabatic capillary tubes with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models were simulated. The predicted pressure distribution, mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing the suitable correlations of friction factor and two-phase viscosity model, and two-phase frictional multiplier.

  • PDF

Dynamic Analysis of the Small Reciprocating Compressors Considering Viscous Frictional Force of a Piston (피스톤의 점성 마찰력을 고려한 소형 왕복동 압축기의 동적 해석)

  • 김태종
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.11
    • /
    • pp.904-913
    • /
    • 2002
  • In this study, a dynamic analysis of the reciprocating compression mechanism considering viscous friction force of a piston used in small refrigeration compressors is performed. The length of cylinder in this class of compressors is shortening to diminish the frictional losses of the piston-cylinder system. So, the contacting length between piston and cylinder liner is in variable with the rotating crank angle around the BDC of the reciprocating piston. In the problem formulation of the compression mechanism dynamics, the change in bearing length of the piston and all corresponding viscous forces and moments are considered in order to determine the trajectories of piston and crankshaft. The piston orbits for viscous friction model and Coulomb friction model were used to compare the effect of the friction forces of piston on the dynamic trajectories of piston. To investigate the effect of friction force acting on the piston for the dynamic characteristics of crankshaft, comparison of the crankshaft loci is given in both viscous model and Coulomb model. Results show that the viscous friction force of piston must be considered in calculating for the accurate dynamic characteristics of the reciprocating compression mechanism.

Analysis of Mechanical Face Seals for Design Purpose. Part II : Thermoelastic, Wearing and Vibrational Effects (설계목적을 위한 기계평면시일의 해석. 제2보 : 열탄성, 마모 및 진동의 영향에 관하여)

  • Kim, Chung Kyun
    • Tribology and Lubricants
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 1991
  • 기계평면시일의 접촉 운동면에서 유체가 비압축성이고, 점성의 영향을 받는 경우에 대한 체적누설 유동량과 마찰 토오크를 멱급수의 방법을 이용하여 추정하였다. 본 연구에서 고려되고 있는 설계인자로 시일의 경사도, 접촉 운동면에서의 사인파형, 코우닝, 열탄성 변화량, 마모량, 시일의 스프링 강성도에 따른 축방햐의 변화량을 종합적으로 고려하여 해석하였다. 계산된 결과에 의하면 특히 회전속도가 증가되면 열탄성 변화량에 의한 시일의 누설 마찰 토오크가 커다란 영향을 받고 있는 것으로 나타나고 있다.

Estimation algorithm for mechanical system parameters based on position control (위치 제어를 기반으로 한 기계 시스템의 제정수 추정 알고리즘)

  • Yoo, Min Sik;Kim, Jae Hyung;Yoon, Young-Doo
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.447-448
    • /
    • 2017
  • 본 논문은 위치 제어 시스템의 기계 제정수 추정 알고리즘을 제안한다. 추정 대상 제정수는 관성모멘트와 점성 마찰계수, 쿨롱 마찰계수이다. 제정수 추정에 대한 오차를 줄이기 위해, 적분 연산과 정현파의 위치 명령을 사용하였다. 시뮬레이션 및 실험을 통하여 이의 유효성을 입증하였다.

  • PDF

Friction Characteristics of Piston Assembly (II) -Experiment- (피스톤계 마찰 특성 (II) -실험적 연구-)

  • Cho, Myung-Rae;Ha, Kyoung-Pyo;Kim, Joong-Soo;Oh, Dae-Yoon;Han, Dong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.88-93
    • /
    • 2003
  • The aim of this paper is to investigate the friction characteristics of piston assembly, which composed of ring pack and piston skirt. The friction force of piston assembly was measured by using the movable liner in the single cylinder engine, and the various parameters were tested. The friction force was suddenly increased at the expansion stroke due to higher cylinder pressure. The viscous friction was dominant at the mid stroke, but the boundary friction was dominant at the top and bottom dead centers. Through the experiment, we could validate previous theoretical study, and confirm that th e radial clearance and ring tension were very effective to reduce friction loss of piston assembly.

A study on the sliding rigid indentor over the viscoelastic layer supported by the elastic half-space (탄성체로 기대된 점잔성체층에서의 강성체의 운동해석)

  • Nam, J. W.
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.56-63
    • /
    • 1983
  • 강성체로된 견인물체가 탄성무한경면으로 지지된 점탄성층 위를 미끄러져 갈 때 접촉구간에서의 압력분포와 마찰 특성을 고찰하였다. 즉, 접촉구간에서의 강성체의 모양과 압력분포에 관한 적분 방정식을 구하고, 점탄성층의 두께가 접촉구간에 비하여 충분히 두꺼울 때 압력분포와 마찰계 수의 근사해를 구하였다. 압력분포의 모양은 점탄성층의 물성을 표시하는 지수값, 즉 .alpha.<1/2, .alpha.=1/2, .alpha.>1/2에 따라서 크게 다르다. 한편, 수치해석에 의하면 마찰 계수에 대한 근 사해는 강성체의 미끄럼 속도, 점탄성 층의 두께, 탄성체의 영율 (E$_{o}$ )과 점탄성층의 시효 성탄성계수 (E$_{v}$ )의 차, 즉 E$_{o}$ /E$_{v}$ 에 따라 변화함을 알 수 있다. 즉, 탄성체가 점탄성층에 비하여 딱딱하면 할수록, 또 강성체 속도가 느리면 느릴수록 마찰계수는 작아진다. 그리고 불성의 지수(.alpha.)가 커지면 커질수록 근사해의 수렵 속도는 느려지게 되고 지 수(.alpha.)가 1에 가까워지면 점탄성층의 탄성효과는 점성효과에 비하여 거의 무시할 수 있으며 근사해는 의미가 없어지게 된다.

  • PDF

Applicability of IGM theory Partial Drilled Shaft constructed on Granite Rocks (화강풍화암에 시공된 부분현장타설말뚝의 IGM이론의 적용성)

  • Ahn, Tae-Bong
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.5
    • /
    • pp.379-385
    • /
    • 2013
  • In this study, partial drilled shafts (Bottom Cast-in-place Concrete pile) were applied to the pilot test site to ensure the bearing capacity; we used the skin friction force in the IGM to analyze the feasibility of the application of IGM theory. The soil characteristics were analyzed in cohesive, non-smear, and smooth conditions for the application of the IGM theory via geotechnical investigation and measurement of the disturbance and surface roughness. Static load and load transfer tests were conducted to calculate the allowable bearing capacity and the skin friction force by depth. The skin friction force increased with increase in the depth and standard settlement, showing a very high correlation. In addition, because the unconfined strength ($q_u$), which is the most important parameter in the cohesive IGM, cannot be measured in a weathered granite area, the static load and load transfer test results and the N value were used to obtain $q_u$.

Load Transfer Characteristics and Ultimate Bearing Capacity of PHC Pile in Deep Soft Clay Layer (대심도 연약지반에 근입된 PHC말뚝기초의 하중전이특성 및 극한지지력 산정)

  • Lee, Yonghwa;Kim, Myunghak
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • In this study, the analysis of load transition of PHC pile was performed with the static load test, which was driven in deep soft clay layer of MyungJi site in the western area of Pusan. The results of test showed that the range of unit side resistance of pile in sand layer were $7.4t/m^2$ to $23.3t/m^2$ and $6.4t/m^2$ in the soft clay layer, while the unit base resistance was $955t/m^2$ in dense silty sand layer. To select the most reasonable static bearing capacity formular, the field measured values are compared with the calculated ones from the suggested various formular. In the case of side resistance in sand layer, the suggest formular in the Structural Foundation Design Manual by KGS was most reasonable, while in clay layer Railroad Design Manual.

  • PDF

Fundamental Study on the Reinforcing Effect of Reinforced Clayey Soil with Nonwoven-geotextile (부직포 보강 점성토의 보강효과에 관한 기초적 연구)

  • 김유성;이재열
    • Geotechnical Engineering
    • /
    • v.14 no.4
    • /
    • pp.61-76
    • /
    • 1998
  • Various kinds of reinforced soil methods have been developed by many researchers or companies for their economic merits mainly. These methods have generally used sandy soils which have high permeability as embanking or backfill material. That is because, if poor embanking materials, especially like a clayey soil which has very low permeability, are used in a reinforced soil embanking, and if excessive pore water pressure is produced by external factors, the friction resistance between reinforcing members and Boils decrease, as a result possible damage or collapse of the body of a reinforced embankment. In fact, clayey Boils can also be used as a embanking materials with reinforcement which has high permeable capacity, and are expected to be able to dissipate the excess pore water pressure effectively. In this study reinforcing effects have been examined through a serries of direct shear tests in which clayey soils are reinforced with nonwoven geotextiles of which permeability is very high and tensile strength is relatively weaker than geogrids which are usually used in reinforced soil wall. Even though such nonwoven geotextile are used as reinforcement of high saturated clayey soils. the test results show the possibility that nonwoven geoteztiles could be used as a reinforcement for reinforced soil walls effectively.

  • PDF