• Title/Summary/Keyword: 점선원

Search Result 48, Processing Time 0.03 seconds

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

A Study for Analysis of Image Quality Based on the CZT and NaI Detector according to Physical Change in Monte Carlo Simulation (CZT와 NaI 검출기 물질 기반 물리적 변화에 따른 영상의 질 분석에 관한 연구: 몬테카를로 시뮬레이션)

  • Ko, Hye-Rim;Yoo, Yu-Ri;Park, Chan-Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.741-748
    • /
    • 2021
  • In this study, we evaluated image quality by changing collimator length and detector thickness using the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera based on the Cadimium Zinc Telluride (CZT) and NaI detectors is modeled. In addition the images were acquired by setting 1, 2, 3, 4, 5, and 6 cm collimator length and 1, 3, 5, and 7 mm detector thickness using point source and phantom, which is designed by each diameter (4.45, 3.80, 3.15, 2.55 mm) with 447, 382, 317, and 256 Bq. The sensitivity (cps/MBq) for point source, and signal to noise ratio (SNR) and profile for phantom at the 4.45 mm by drwan the region of interests were used for quantitative analysis. Based on the results, the sensitivity according to collimator length is 2.3 ~ 48.6 cps/MBq for CZT detector, and 1.8 ~ 43.9 cps/MBq for NaI detector. The SNR using phantom is 3.6~9.8 for CZT detector, and 2.9~9.5 for NaI detector. As the collimator length is increased, the image resolution is also improved according to profile results based on the CZT and NaI detector. In addition, the senistivity for detector thickness is 0.04 ~ 0.12 cps/MBq for CZT detector, and 0.03 ~ 0.11 cps/MBq. The SNR using phnatom is 7.3~9.8 count for CZT detector, and 5.9~9.5 for NaI detector. As the detector thickness is increased, the image resolution is decreased according to profile results based on the CZT and NaI detector due to scatter ray. In conclusion, we need to set the geometric material such as detector and collimator to acuquire suitable image quality in nuclear medicine.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Effect of Dietary Fiber from Soybean Hull on the Recovery of Diarrhea in Rats (대두피로부터 분리한 식이섬유가 설사개선에 미치는 영향)

  • Yim, Ji-Hyuck;Cheong, Il-Hwan;Park, Tae-Hwa;Lee, Yoon-Bok;Han, Jae-Heum;Park, Jeom-Seon;Lee, Kyun-Hee;Lee, Sang-Hwa;Ahn, Jun-Bae;Kim, Kwang-Yup;Lee, Keun-Ha;Sohn, Heon-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.588-592
    • /
    • 2007
  • In this study, we evaluated the recovery effects of dietary fiber extracted from soybean hulls on diarrhea in rats. Diarrhea-induced Sprague-Dawley male rats were divided randomly into 4 groups and fed experimental diets for 24 hours. The diets, based on the AIN93G diet, were as follows: CON (control diet), S-COTL (67.2 g/kg soybean cotyledon fiber diet), S-HULL (59.6g/kg soybean hull fiber diet), CHI (55.6g/kg chicory fiber diet). The results showed significant (10-20%) reductions of fecal water content in the CON and S-HULL groups, as compared to the S-COTL and CHI groups. The change in serum osmolality, a measure of dehydration symptoms, was significantly reduced in CON and S-HULL as compared to the S-COTL and CHI groups. Based on the results, it is suggested that soybean hull fiber functions well for diarrhea recovery in rats. Consequently, soybean hull fiber is an important food source that could be used as a medical food in patients suffering from diarrhea.

Estimation of the Moisture Maximizing Rate based on the Moisture Inflow Direction : A Case Study of Typhoon Rusa in Gangneung Region (수분유입방향을 고려한 강릉지역 태풍 루사의 수분최대화비 산정)

  • Kim, Moon-Hyun;Jung, Il-Won;Im, Eun-Soon;Kwon, Won-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.9
    • /
    • pp.697-707
    • /
    • 2007
  • In this study, we estimated the PMP(Probable Maximum Precipitation) and its transition in case of the typhoon Rusa which happened the biggest damage of all typhoons in the Korea. Specially, we analysed the moisture maximizing rate under the consideration of meteorological condition based on the orographic property when it hits in Gangneung region. The PMP is calculated by the rate of the maximum persisting 12 hours 1000 hPa dew points and representative persisting 12 hours 1000 hPa dew point. The former is influenced by the moisture inflow regions. These regions are determined by the surface wind direction, 850 hPa moisture flux and streamline, which are the critically different aspects compared to that of previous study. The latter is calculated using statistics program (FARD2002) provided by NIDP(National Institute for Disaster Prevention). In this program, the dew point is calculated by reappearance period 50-year frequency analysis from 5% of the level of significant when probability distribution type is applied extreme type I (Gumbel distribution) and parameter estimation method is used the Moment method. So this study indicated for small basin$(3.76km^2)$ the difference the PMP through new method and through existing result of established storm transposition and DAD(Depth-Area-Duration). Consequently, the moisture maximizing rate is calculated in the moisture inflow regions determined by meteorological fields is higher $0.20{\sim}0.40$ range than that of previous study. And the precipitation is increased $16{\sim}31%$ when this rate is applied for calculation.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.