• Title/Summary/Keyword: 절연 피복

Search Result 38, Processing Time 0.025 seconds

Bond Strength of SrZrO3 Coatings on Ag Sheathed Bi(2223) Mono-core Tape (은이 피복된 단심 Bi(2223) 초전도 선재에 대한 SrZrO3 코팅층의 접착강도 특성)

  • Lee, Se-Jong;Ye, Kyung-Hwan;Lee, Deuk-Yong;Song, Yo-Seung
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.1001-1006
    • /
    • 2002
  • Bond strength of $SrZrO_3$ resistive oxide barrier on Ag sheathed Bi(2223) tapes prepared by the sol-gel and dip-coating method was evaluated with an aid of Taguchi method and $L_18(2^1{\times}3^7)$ orthogonal arrays to determine the optimal process combination of levels of factors that best satisfy the bigger is better quality characteristic. The observed optimal condition is as follows: Sr/Zr mol ratio(0.3/0.7), amount of organic vehicle(5 wt%), drying temperature and time(160${\circ}C$, 10 min), heat treatment temperature and time(500${\circ}C$, 20 min), respectively. ANOVA analysis suggested that the influence of the factors within ${\alpha}$=0.1 was significant with a 90% confidence level.

Study of Fire Examples for Electrical Wire Short and Insulated Coating Melting by Heating Including Automotive Engine Room (자동차 엔진룸 관련 전기 배선의 단락 및 열에 의한 절연피복 용융에 대한 화재사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Youm, Kwang Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.15-19
    • /
    • 2013
  • This paper is to analyze and study the cause of fire examples produced because of short phenomenon by electric connecting damage and contacting engine over-heating with combustible materials in engine room of vehicle. In the first example, it knew the fact that the fire produced by contacting with body of vehicle because of loosed of bracket bolt for wire fixing that installed on the transmission case the battery power cable supply the power from battery of engine room to starting motor. In the second example, it certified the fire by short phenomenon because of insulation tape melting wound wiring lined from battery to starting motor. In the third example, it sought for fire's cause that melting phenomenon the wire coating by overheated engine as the wire disconnected with connector by the vibration. Therefore, the fire of system including engine electric made in the danger the people in the car by failure of engine and other system. And than, the car's driver must manage and examine a vehicle conscientiously.

Failure Analysis of LV URD Cable based on FMEA (FMEA에 근거한 LV URD 케이블의 고장분석)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Young-Seok;Kim, Sun-Gu;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.90-98
    • /
    • 2007
  • The objective of this investigation was to reveal the cause of the faulted cable(LV URD(low voltage underground) cable). For the analysis, various types or equipments such as external pattern, thermal pattern, surface structure, thermal analysis, and property distribution were deployed. The international standards and the specification provided by the manufacturer of faulted cable were examined whether it fit the standards. The summary is as follows. (1) Discovered as a factor lowering insulation performance of the faulted cable: minimum thickness of the insulation layer specified by IEC 60502-1 and IEC 60811-1-1 was not fit. (2) Infrared absorption peaks measured by FT-IR spectrometer revealed that the measurements made for the same material did not conform and it is an important basis for proving heterogeneous composition of the insulation material. (3) It was found that PVC bedding was thermally fragile and therefore long term exposure at the site could cause similar fault pattern.

Experimental Studies on the Risk Assessment of Electrical Fire and Shock of LED Lighting for Outdoor (옥외용 LED 조명의 전기화재 및 감전 위험성 평가에 대한 실험적 고찰)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.77-97
    • /
    • 2011
  • In this paper, we studied risk assessments of electrical fire and shock of LED lightings for outdoor. We examined national regulations about the LED lighting for outdoor and analyzed the appearances and compositions of LED lightings. And, We experimented about water proof, line to line fault, line to line breakdowm, overvoltage, line to line leakage in overhead line or water of LED lighting. From experimental results, we know that there are risks of electrical fire and shock by abnormal conditions at the LED lighting. Therefore, the uses of protective devices and insulated type of converter are required for the electrical safety. We expect that the results of this study would be helpful for the improvement of regulations and standards for electrical safety and for the investigations of electrical accidents of LED lightings.

  • PDF

THE STUDY OF FRACTURE STRENGTH OF PORCELAIN LAMINATE VENEER WITH VARIOUS LINGUAL EXTENTION LENGTH WHEN LNCISAL RESTORING (Porcelain Laminate veneer 절연 피복시 설측 연장 길이에 따른 파절강도의 연구)

  • Park, Johng-Han;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.746-754
    • /
    • 1996
  • The purpose of this study was to evaluate the fracture strength of porcelain laminate veneer with various lingual extention length when incisal restoring. Sixty recently extracted, intact maxillary incisors were used and stored in a physiologic saline solution from the time of extraction. Seating form was preparation at the labial surface of each tooth with a water-cooled round diamond bur. Standard block was formed with 32 gauge and 24 gauge wax at tooth labial and lingual surface. Lingual extention length differed according to each group. (group I : 0.5mm, group II : 1 mm, group III : 2mm, group IV : 0mm) All tooth specimens were impressioned with examix(GC Inc., Japan). Refractory cast were maked with refractory die material(Ceramco Inc., U.S.A.) Laminate porcelain (Ceramco II Veneer porcelain, Ceramco Inc., U.S.A.) was condensed in refractory die cast and baked according to the manufacturer's recommendations. Each surface was contoured with low speed diamond bur according to guide block. All porcelain specimens were sandblasted and ultrasonically cleaned in distlled water for 3 minutes. Then, all porcelain specimen were etched with 8% hydrofluoric acid for 5 minutes. Sixty specimens were bonded with composite resin cement(Choice Porcelain Veneer System, Bisco Inc., U.S.A.) according to manufacture's directions. The fracture loads of the specimen were measured by Instron universal testing machine. The mean values of fracture loads for the groups were statistically compared by Duncan's multiful range test. The result were as follows : Mean fracture strengths of each group were 86.95Mpa in no lingual extention group, 44.98Mpa in 0.5mm lingual extention group, 27.47Mpa in 1mm lingual extention group, 19.61Mpa in 2mm lingual extention group. There was a statistically significant difference between all group(p<0.01).

  • PDF

A Characteristic of Tracking Progress Happened at the End of the VCTFK (VCTFK 끝단에서 발생되는 트래킹의 진전특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Ok, Kyung-Gea;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.78-83
    • /
    • 2010
  • This paper describes the characteristic of tracking progress happened at the end of the polyvinyl chloride insulated cabtyre oval cord(VCTFK) that is widely used for distribution cord. Tracking is occurred owing to the drop of electrolyte at the end of the VCTFK. The tracking progress and its characteristic happened at the end of the VCTFK are as follow; Carbonization and electrical erosion are happened at the end of the VCTFK. Electrical erosion is begun at the insulation layer near conductors. After that, it is also happened at the sheath layer. Accumulation of carbonized insulation and sheath materials at the end of the VCTFK is begun after progress of electrical erosion. When the accumulation is progressed arc discharge is appeared and finally it goes to tracking breakdown.

Study on the damage effect to the Gas pipeline coating by the crashed stone backfill material (쇄석을 가스배관 채움재로 사용시 배관피복에 미치는 영향 연구)

  • Cho Sung Ho;Jeon Kyung Soo;Li Seon Yeob;Cho Yong Bum;Kho Young Tei
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.23-27
    • /
    • 1998
  • To protect the underground pipeline from the mechanical damage and to enhance the cathodic protection effect, the river sand has been backfilled traditionally around the buried pipeline. However, river sand became depleted and expensive. One has to seek for the economic alternative materials. Crashed stone is a good candidate for the backfill material. In this study, how much the particle size and shape of the crashed stone can effect on the gas pipeline coating was examined. A series of laboratory and field test was performed. In the Lab, the increasing loads were applied to the coated pipeline surrounded by the crashed stone, where no significant damage was observed.

  • PDF

Application of Dielectric Sensor for Soil Moisture Measurement (토양 수분 측정을 위한 유전율식 쎈서 연구)

  • Oh, Yong-Taeg;Oh, Dong-Shig;Song, Kwan-Cheol;Shin, Jae-Sung;Im, Jung-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.2
    • /
    • pp.85-94
    • /
    • 1998
  • Due to relatively high permittivity of water in soils, we placed the soil condenser into soils to measure the soil moisture content. The soil condenser was made with two insulated iron sticks. The capacitance of the soil condenser was determined by the pulse period from RC type oscillation circuit and the highest voltage output accepting 10MHz pulse. After zero point adjustment, the measured relative capacitance percentage (RCS) to the standard condenser obtained by the oscillation circuit almost linearly correlated with the end depth of the sensor submerged in water. The RC type oscillation was disturbed by many sensor installed in a close distance in one place, presumably resulting in that the sensor sticks played as a interfering antennas generating or accepting electron waves from them. The temperature dependance of the output from the sensors could be corrected through experimentally determined revision function. Although lineal correlation was found between soil moisture and RCS, users should derive their own correlation function for every sensor to measure soil moisture, because the outputs were influenced by the installation depth and layout in the soil. The voltage type sensor responded inversely with soil moisture content and so was not suitable to the accurate measurement of soil moisture, but allows high economic benefit in various application such as simplified measurement of soil moisture and irrigation line control because of its low component count. The voltage type moisture sensor could be reinforced by relay controlling circuit to open and to close the solenoid valves respectively at optimal limits of the least and the most soil moisture according to user's adjustment.

  • PDF