• Title/Summary/Keyword: 절대형 탐촉자

Search Result 2, Processing Time 0.019 seconds

Development and Calibration of a Plate Type Eddy Current Standard (평판형 와전류 표준 시험편의 개발 및 교정)

  • Kim, Young-Joo;Kim, Young-Gil;Ahn, Bong-Young;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.393-397
    • /
    • 2007
  • Eddy current standard including an artificial slot for the calibration of absolute type surface probe was fabricated. Developed eddy current standard has the electric conductivity and dimensions, and contains artificial slot as established in ASTM E 1629. The width and depth of artificial slot are 0.1 mm and 0.5 mm respectively. This slot was only possible to measure the depth on the two side edges, and impossible for the middle part with general measurement tools. The ultrasonic test method was applied for measuring depth of the middle part of the artificial slot in the standard. Using this method the dimension could be measured successfully with uncertainty about $15\;{\mu}m$. Calibration of eddy current standard for the absolute probe can be performed by this technique.

A Study on the Transducer Calibration for Acoustic Emission Measurement (AE 측정을 위한 탐촉자의 보정에 대한 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.53-58
    • /
    • 1996
  • In order to investigate the source mechanism of micro cracks through acoustic emission measurement induced by rock fracture, careful calibration of the entire linkage of the detecting system, from the transducers to transient recorder, is an essential requirement prior to testing. Transducers and digitiging system are generally the weakest links in the measurement system because they must translate mechanical motions into digital electric signals. In this study, PAC piezoelectric pressure transducers are calibrated with a standard NBS conical shaped displacement transducer and a DG piezoelectric displacement transducer. The NBS and PAC transducers are insensitive to changes in horizontal impingement angle but sensitive to changes in incident angle. The ray path along the logitudinal axis of the tranducer produced a maximum response while the ray path perpendicular to the transducer axis gave a minimum. And a difference in individual transducers factor for a peak-to-peak amplitude of PAC transducers was within 40%. An average PAC transducer coefficient was determined as 77mv/pm by an absolute calibration test using NBS transducer.

  • PDF