• Title/Summary/Keyword: 절단 경로 수정

Search Result 4, Processing Time 0.019 seconds

A Modification of the Shapiro-Wilk Test for Exponentiality Based on Censored Data (중도절단자료에 대한 수정된 SHAPIRO-WILK 지수 검정)

  • Kim, Nam-Hyun
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.2
    • /
    • pp.265-273
    • /
    • 2008
  • Kim (2001a) presented a modification of the Shapiro and Wilk (1972) test for exponentiality based on the ratio of two asymptotically efficient estimates of scale. In this paper we modify this test statistic when the sample is censored. We use the normalized spacings based on the sample data, which was used in Samanta and Schwarz (1988) to modify the Shapiro and Wilk (1972) statistic to the censored data. As a result the modified statistics have the same null distribution as the uncensored case with a corresponding reduction in sample size. Through a simulation study it is found that the proposed statistic has higher power than Samanta and Schwarz (1988) statistic especially for the alternatives with the coefficient of variation greater than or equal to 1.

Improvement in Dimensional Accuracy of Transfer-type for Variable Lamination Manufacturing using Expandable Polystyrene Foam (VLM-ST의 형상정밀도 향상에 관한 연구)

  • 최홍석;이상호;안동규;양동열;문영복;박두섭;채희창
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.1047-1050
    • /
    • 1997
  • Rapid Prototyping(RP) is an efficient method for rapid design verification and trial manufacturing. In order to improve their unique characteristics according to the working principles. Variable Lamination Manufacturing process and corresponding CAD/CAM system is developed. The objective of this study is to improve dimensional accuracy of VLM-ST process, and it can be done by offset for cutting error correction, cutting path correction for sharp edge and reference shape generation. To verify the proposed algorithms, they applied to three-dimensional shapes, such as spanner and mechanical part.

  • PDF

Utilization of Domestic Natual Quartz as Elecrtic Resonators; Feasibility Study (한국산 천연수품을 이용한 수품공진자의 생산가능성에 관한 연구)

  • Choe, Se-Gon;Jeong, Gi-Ho;Lee, Mu-Yeong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.3
    • /
    • pp.11-15
    • /
    • 1976
  • 한국산 천연수정은 보석장식용으로서는 그 품질이 이미 알려져 있으나 수정진동자로서의 특성에 관해서는 아직 보고된 바가 없다. 본 연구는 특히 경상도일대에서 채굴되고 있는 천연수정을 채집, 선별, 가공하여 그 수정진동자로서의 사용가능성을 실험을 통하여 검토한 것이다. 필자들은 채굴현장 근처에서 채집한 원석을 특별히 고안제작된 검사경을 이용하여 분석선별하였으며 X-ray를 사용하여 AT-cut로 orientation 한후 시판을 절단하였다. 다음 적용하여 전기적, 광학적 쌍수상태를 검토하고 다시 선별하였다 Dimensioning은 5MHz를 목표로 하였는데 연잠제를 사용하여 5MHz의 조도까지 연마하고 전극으로서 표준형의 은막을 부착하여 시판을 완성하였다. 시판을 대한 측정결과는 모든 등가정수가 대표적인 수입수정판의 것과 대등하였으며 특히 Q는 모두 105를 넘었다. 온도특성도 AT-cut의 이론치와 대차가 없었으며 -20℃-+100℃ 범위에서 최대 20PPM 이내의 편차를 보였다. 즉, 한국산 천연수정은 적절히 선별, 가공 한다면 부유한 수정진동자의 원재로서 사용할수 있음이 증명되었다. Samples of domestic natural quartz were collected and screened optically and chemically, and, after weeding out portions unfit for electrical resonator, were cut into AT-cut wafers, which in turn were dimensioned, trimmed and lapped into 5MHz resonator units. The results of measurements obtained from the specimens indicated excellent electrical characteristics of domestic natural quartz with the average Q quotient of 10s or higher. Temperature characteristics also showed typical AT-cut corves with the frequency deviation of 20PPM at maximum throughout the range of -20 to 100℃. The experiment on the initial batch of samples amply indicates the excellent electrical quality of domestic natural quartz as quartz resonator units.

  • PDF

Portal Placement for Thoracoscopic Right Middle Lung Lobectomy with One-Lung Ventilation in Beagle Dogs (비글견에서 편측성 분리폐 환기를 이용한 흉강경 우중폐엽 절제술을 위한 포트 위치)

  • Park, Ji Young;Lee, Hae-Beom;Jeong, Seong Mok
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • Purpose of this study is to determine the reasonable portal approach for thoracoscopic right middle lung lobectomy in small sized dogs under 10 kg. Ten healthy beagle dogs weighing $8.67{\pm}0.49kg$ were included. Under general anesthesia, one-lung ventilation (1LV) was achieved using endobronchial blocker with guidance of fiber-optic bronchoscope. Two portal approaches were used; 8-6-10 intercostal space (ICS) and 8-6-5 ICS approach. Thoracoscopic right middle lung lobectomy was performed using endoscopic linear self-cutting stapler and specimen retrieval bag. Each approach was evaluated by scoring 0; bad, 1; endurable, 2; good, 3; excellent in following five category, 1) visualization, 2) triangulation; instrumental sword fighting in the thoracic cavity, 3) approach to hilar pedicle; application of stapler, 4) any obstacles in applicating Lap Bag, and 5) the operator's convenience. Favorable working space was secured by 1LV and thoracoscopic right middle lung lobectomy was successfully completed in all dogs. There was no need to change the portal location and iatrogenic complication. Most of scores were good to excellent in both approaches. Consequently, both approaches are feasible methods for thoracoscopic right middle lung lobectomy with one lung ventilation using endoscopic linear self-cutting stapler in dogs weighing less than 10 kg.