• 제목/요약/키워드: 절감량

검색결과 1,390건 처리시간 0.029초

우리아파트 녹색아파트-동작구 상도삼호아파트

  • O, Hye-Eun
    • The Magazine for Energy Service Companies
    • /
    • 통권45호
    • /
    • pp.28-31
    • /
    • 2007
  • 5개동 682세대가 입주해있는 서울시 동작구 상도동에 위치한 상도삼호아파트는 지난 2006년 7월 182kW 열병합발전기 2기를 설치했다. 발전기를 가동한지 4개월이 지난 지금 에너지 절감량 목표량의 120%를 초과 달성하고 있는 상도삼호아파트를 찾았다.

  • PDF

Analysis of Energy Savings and CO2 Emission Reductions via Application of Smart Grid System (지능형 전력망(스마트 그리드) 적용을 통한 에너지 절감 및 CO2 감축 효과 분석)

  • Park, Soo-Hwan;Han, Sang-Jun;Wee, Jung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제39권6호
    • /
    • pp.356-370
    • /
    • 2017
  • The energy savings and $CO_2$ emission reductions obtainable from the situation that the Smart Grid system (SGs) is assumed to be applied in Korea up to 2030 is quantitatively analyzed with many reported data. For calculation, SGs is divided into five sectors such as Smart Transmission and Distribution (ST&D), Smart Consumer (SC), Smart Electricity Service (SES), Smart Renewable Energy (SRE) and Smart Transportation (ST). Total annual energy savings in 2030 is estimated to be approximately 103,121 GWh and this is 13.1% of total electricity consumption outlook. Based on this value, total amount of reducible $CO_2$ emissions is calculated to 55.38 million $tCO_2$, which is 17.6% of total nation's GHG reduction target. Although the contribution of energy saving due to SGs to total electricity consumption increases as years go by, that of $CO_2$ emission reduction gradually decreases. This might be because that coal fired based power generation is planned to be sharply increased and the rate of $CO_2$ emission reduction scheduled by nation is very fast. The contributable portion of five each sector to total $CO_2$ emission reductions in 2030 is estimated to be 44.37% for SC, 29.16% for SRE, 20.12% for SES, 5.11% for ST&D, and 1.24% for ST.

Studies on the application of unit-inverter parallel operation to sea-water lift pump in power plant(I) (단위 인버터 병렬운전에 의한 발전소 해수펌프 적용(I))

  • 김수열;류홍우
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.285-289
    • /
    • 1997
  • 발전설비의 대형화로 인하여 소내소비 전력량이 점점 증가하고 있는 추세이며 대용량의 화력발전소라 하더라도 기저부하보다는 부하조정의 역할이 강해져 정격속도로 운전하던 팬, 펌프등을 필요 부하에 따라 회전수를 제어하여 전력절감을 꾀하여야 할 필요가 있다[1]. 이에 따라 생산기술개발 과제로 개발한 대용량 GTO 인버터 시스템을 서 인천복합화력발전소의 3상 6600V 1500KW 용량인 전동기 구동 해수펌프에 적용하기 위한 기술적 검토 내용과 계산된 전력 절감량을 제시하였다. 적용 시스템으로는 개발된 3상 660V 1MVA 단위 인버터를 병렬 운전시켜 2MVA의 용량으로 하였으며 인버터의 입출력 단에 변압기를 설치하여 강압 및 승압 시켜 사용하였다.[2]

  • PDF

A Study on Ways to Improve Benefits of Travel-time in Analyzing the Economic Efficiency (경제성분석시 통행시간절감편익 개선방안에 관한 연구)

  • Lee, Sooil;Lee, Seungjae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제30권3D호
    • /
    • pp.263-270
    • /
    • 2010
  • This research has reviewed the ways to improve the benefits of shortening of transit hours among the benefit items in analysis of economic efficiency. The existing way of calculating the benefits of shortening the transit hours in analysis of economic efficiency has been using O/D in peak to multiply by 365. This method has a problem of not considering the change of traffic according to the month and the day of the week. To improve such problem, the volume of traffics at 361 regular research branches of the chronological statistics of traffic volume was used to analyze the pattern change of traffic volume per day of the week and per month by t-test and cluster analysis. The results show a difference in traffic volume according to the day of the week and the month. In the research example, a supposed O/D and network were used to apply weight per day of the week and per month to see a slight difference with the existing method of calculating benefits of shortening the transit hours. This signifies the necessity to study about the weight to consider the change pattern of traffic volume.

The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings (대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석)

  • Kim, Byung-Soo;Gil, Young-Wok;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제23권12호
    • /
    • pp.176-183
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat, and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30[%] after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40[%]. If electricity energy and waste heat in turbine are used, 56[%] of heating energy and 67[%] of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70[%].

Study on Effective EERS Savings Calculating Method through Analysis of Energy Consumption of Electric Motor & Lighting Devices (전동기와 조명기기의 에너지사용 분석을 통해 효과적인 EERS 절감량 산정을 위한 주요인자 도출 연구)

  • Yeom, Jeehoon;Choi, Hanho;Lee, Hyunwoong;Park, Sungwoo;Kim, Changsik;Hahn, Seunghee
    • Journal of Energy Engineering
    • /
    • 제28권3호
    • /
    • pp.34-41
    • /
    • 2019
  • It is essential to introduce EERS (Energy Efficiency Resource Standards) according to the trend of the era in which energy saving is emphasized, and it is time to settle down in a stable manner. Electric motors and lighting devices, which account for more than 60% of the nation's electricity use, are the most effective items of the EERS. And accurate methods of calculating savings must be preceded. In this study, the operation rate and load rate are measured through the demonstration of energy use at 400 businesses and the measured rates are used for EERS savings calculation. The results imply that the proposed method can be successfully applied to calculate cost-effective and reliable energy savings.

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제19권6호
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

A Study on LED Light Energy Saving using the Predicted Demand and illumination (산업시설 내부 LED조명의 수요 예측과 조도의 자동 조절을 이용한 전력 절감)

  • Choi, Seong-Min;Lee, Byeong-Rae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 한국정보처리학회 2016년도 춘계학술발표대회
    • /
    • pp.766-769
    • /
    • 2016
  • 산업시설 가운데 화력발전소에 스마트 부하관제 시스템을 이용하여 메탈 조명을 LED 조명으로 대체하여 전력을 절감하였다. LED 조명의 빛의 세기를 조절 할 수 있는 디밍을 통해서 사용자의 다양한 요구사항을 반영할 수 있다. 수요 예측은 전력 사용량이 많은 시간대의 전력사용량을 분산시키는 시스템이다. 수요 예측 스케줄에 의해서 목표전력량에 도달하기 위해 설정된 시간대에 디밍으로 LED 조명의 전력량을 조절하여, 기존 LED 조명 대비 전력량을 27.8% 절감하였다. 외부에 눈과 비가 오거나 밤에 실내가 어두워져서 작업 환경에 영향을 미치는 경우가 있다. 실시간으로 조도를 측정하여 작업 환경이 원활한 기준조도에 맞도록 LED 조명을 디밍 하여 작업환경을 개선하였다.