• 제목/요약/키워드: 전체 측정정밀도

Search Result 170, Processing Time 0.036 seconds

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Results of the Precision Monitoring (바이오가스 이용 기술지침 마련을 위한 연구(II) - 정밀모니터링 결과 중심으로)

  • Moon, HeeSung;Bae, Jisu;Park, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.65-78
    • /
    • 2018
  • According to the in social aspects such as population growth, urbanization and industrialization, development of livestock industry by meat consumption, amount of organic wastes (containing sewage sludge and food waste, animal manure, etc) has been increased annually in South Korea. Precise monitoring of 11 organic wastes biogas facilities were conducted. The organic decomposition rate of organic wastewater was 68.2 % for food wastes, 66.8 % for animal manure and 46.2 % for sewage sludge and 58.8 % for total organic wastes. As a result of analyzing the biogas characteristics before and after the pretreatment, the total average of the whole facility was measured to be 560 ppm using iron salts and desulfurization, and decreased to 40 ppm when the reduction efficiency was above 90 %. Particularly, when iron salt is injected into the digester, the treatment efficiency is about 93 %, and the average is reduced to 150 ppm. In the case of dehumidification, the absolute humidity and the relative humidity were analyzed. The dew point temperature of the facility where the dehumidification facility was well maintained as $14^{\circ}C$, the absolute humidity was $12.6g/m^3$, and the relative humidity was 35 %. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure) through precision monitoring.

Portable thermocouple thermometer on the nonlinearity compensation (비선형 특성을 보정한 휴대용 열전대 온도계)

  • Kim, Seong-Kuk;Song, Jae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1995
  • A portable type K thermocouple thermometer is designed and fabricated to compensate the linearity to the high temperature $1000^{\circ}C$. The problems to be solved, which use a thermocouple thermometer are the compensation of the nonlinearity characters and reference compensation. The nonlinear character of the thermocouple is compensated, using an EPROM, and the reference compensation done using an IC AD595A. Before this compensation, there was the maximum error of $23.6^{\circ}C$(2.69%) at $876^{\circ}C$. However the results measured by the portable type K thermocouple thermometer fabricated show the character of the error of ${\pm}2^{\circ}C$(0.2%) in the range of the total temperature. This character satisfies the precision specifications of the type K thermal sensors in the range available $1000^{\circ}C$, which can be measured by the use of type K thermocouples. Therefore the portable type K thermocouple thermometer fabricated can be comparatively exactly used for the wide range of temperature of interest. Then this technique of compensating the nonlinear characters can be applied to the other kinds of thermal sensor compensation.

  • PDF

Analysis of dynamic downpull force on the underflow type floating gate with its shape (부력식 수문의 형상에 따른 동적 하향력 분석)

  • Lee, Ji Haeng;Choi, Jong Geun;Choi, Heung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.42-42
    • /
    • 2019
  • 유량조절을 위한 자동수문은 설정된 관리수위 이하에서는 수문이 개방되지 않으며, 유량이 증가하여 관리수위 이상이 되면 수문이 개방되어 방류를 시작하여 일정 수위를 유지하는 것을 의미한다. 자동수문의 운영 중 수문의 거동과 자동 개폐 시점을 예측하는 것은 정밀한 수문 설계를 위해 매우 중요하다. 수문 하단으로 흐름이 발생하면 수문 선단을 포함한 주변에서의 압력 차이로 인한 동수압 하중이 발생하고 진동을 유발, 수문 개방을 억제하는 하향력 등의 효과로 수문 운영에 큰 영향을 미친다. 본 연구에서는 부력식 수문의 모형실험을 통하여 정수압 상태의 부력 이론에 의한 수문 개방률과 측정에 의한 수문 개방률을 비교하였으며, 이론과 측정 수문 개방고의 차이를 하향력에 의한 효과임을 확인하였다. 부력식 수문의 하향력을 검토하기 위해 기존 이론식을 이용한 결과, 이론식은 부력식 수문에 적용하기 어려운 것으로 나타났다. 따라서, 기존 이론식을 이용하여 부력식 수문의 하향계수 산정을 위한 매개변수 관계식을 개방률을 이용하여 제시하였다. 제시된 매개변수 관계식의 결정계수는 0.721, 수정된 결졍계수는 0.690으로 나타났다. 부력식 수문의 형상비에 따른 하향력을 검토하기 위해서 수치모의를 수행하였다. 모형실험에서 측정된 자료와 수치모형 ANSYS-Fluent의 사용성을 검증하였고, 부력식 수문의 형상비를 0.24, 0.49, 0.69, 0.89, 1.09로 총 5가지로 설정하여 하향계수와 하향력을 분석하였다. 부력식 수문의 하향계수와 하향력 검토는 부력체, 스커트로 구분하여 분석을 수행하였다. 하향계수 분석결과, 하향계수는 개방률이 증가함에 따라 감소하였으며 하향계수가 부력체 부분에서는 0.465~1.542, 스커트 부분에서는 0.058~1.148의 범위로 나타났다. 하향력 분석결과, 하향력은 개방률 0.300 이하에서는 개방률이 증가함에 따라 하향력은 증가하였나 개방율 0.300 초과하면서부터 개방률이 증가함에 따라 하향력이 감소하는 것으로 나타났다. 또한 부력체 부분에서는 형상비가 증가함에 따라 하향력이 감소하였으나, 스커트 부분에서는 형상비가 증가함에 따라 하향력이 증가하였다. 이는 형상비가 증가함에 따라 스커트 부분의 면적이 증가하기 때문이다. 부력식 수문의 전체적인 하향력을 계산한 결과, 부력식 수문의 하향력은 0.002~0.015 kN의 범위를 가지며 형상비가 증가함에 따라 부력식 수문에 발생하는 하향력은 증가하는 것으로 나타났다.

  • PDF

Experimental study of flow separation upstream of the riverine weir (하천 보 전방의 박리 흐름에 대한 실험적 연구)

  • Bang, Joo Young;Seo, Il Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.49-49
    • /
    • 2020
  • 하천 보 상류영역에서 발생하는 박리 흐름을 분석하기 위해 실험수로에 하천보 모형을 설치하고, 보 주변에서 발생하는 흐름 구조를 입자 영상 유속계(PIV)로 이용하여 정밀하게 측정하였다. 본 연구에 사용된 보는 하천 설계기준을 따른, 전방 수직벽과 하류 경사램프가 있는 유한한 마루 길이 보이다. 실험 조건은 보 상·하류부 수심으로 인한 4가지 흐름(Hydraulic jump, Plunging jet, Surface wave, Surface jet)을 기반으로 설정하여 수리조건에 따른 유속 특성을 규명하였다. 실험에서 측정한 수직-수평방향 평균 유속·유선도를 분석한 결과, 보 전방의 하부에서 재순환 흐름이 관측되었고, 역방향 흐름도 이 지역에서 발견되었다. 유속 편차의 제곱 평균(Root Mean Square) 흐름장에서 보 전방과 재순환 흐름 영역에 불안전한 흐름이 강하게 발견되었다. 역방향 흐름은 박리 흐름에서 발견되는 주요 특성으로, 역방향 흐름의 전체 면적을 매 관측마다 측정하여 이를 분석한 결과, 재순환 흐름의 면적은 오른쪽으로 기울어진 분포를 가지고, 항상 0보다 큰 값을 가지는 것으로 나타났다. 재순환 면적에 따른 흐름 특성은 역방향 흐름 면적에 대한 조건부 평균을 이용하여 파악했는데, 조건부 평균의 구간은 재순환 흐름의 중심에서 지배적인 주기값을 이용했다. 역방향 흐름이 작은 영역에선, 보 상류의 흐름이 재순환 흐름으로 말려들어가는 열린 박리흐름이 나타나며, 역방향 흐름이 큰 경우에는 재순환 영역의 흐름은 보 상류의 흐름과 분리되는 닫힌 박리흐름이 발생하였다. 역방향 흐름이 가장 큰 경우, 보 전방의 박리흐름은 보의 상단을 넘는 것으로 관찰되었다. 이러한 결과를 통해 보 마루에서 발생하는 박리흐름이 보 전방에 박리흐름에 영향을 미치는 것으로 파악되었다. 조건부 평균된 역방향 흐름의 면적과 박리 지점(separation point)의 관계를 분석한 결과, 역방향 흐름의 오른쪽으로 기울어진 분포와 대규모 흐름 방출 현상이 관측되었다. 박리 지점의 위치와 수리 매개변수의 관계를 분석한 결과, 상류의 수심 증가에 따라 증가하는 경향이 나타났다.

  • PDF

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Energy Conversion Efficiency of TiO2 Dye-sensitized Solar Cells with WO3 Additive (WO3가 첨가된 TiO2 염료감응형 태양전지의 에너지 전환 효율)

  • Lee, Sung Kyu;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-30
    • /
    • 2011
  • In order to improve the energy conversion efficiency of dye-sensitized solar cell (DSSC), the photoelectrode was manufactured by using $TiO_2$ and $WO_3$ on combination effects of two conduction bands. The smash procedure of $TiO_2$ and $WO_3$ was carried out by using a paint shaker to enlarge the contact area of semiconductor with dye and electrolyte. The energy conversion efficiency of prepared DSSC was improved about two times from current-voltage curve based on effects of $WO_3$ and smash. The mechanism was suggested that the conduction band of $WO_3$ worked for prohibiting the trapping effects of electrons in conduction band of $TiO_2$. This result is attributed to the prevention of electron recombination between electron in conduction band of $TiO_2$ with dye and electrolyte. Impedance results indicate the improved electron transport at interface of $TiO_2$/dye/electrolyte.

Numerical Simulation of Changes on Mixed Layer Depth with Climate Variability : SCHISM model (기후변동성을 고려한 연안해역의 혼합층 두께 변화양상 검토: SCHISM 적용)

  • Yoo, Hyung Ju;Lee, Joon-Soo;Kim, Dong Hyun;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.273-273
    • /
    • 2022
  • 혼합층(Mixed layer)은 온도가 일정한 수심층으로, 해수표면에 작용하는 바람의 영향으로 인하여 해수가 위아래로 섞여 형성된다. 이러한 혼합층은 영양염의 순환과 산소의 공급 등과 함께 일차생산량을 결정하는 중요한 요인이 될 수 있으며 혼합층 두께의 변동은 양식 산업에 영향을 미칠 수 있다. 최근에는 기후변화로 인한 해수면 상승 및 해수온 상승 등이 지속되고 있으며, 이러한 현상은 해양생태계의 변화를 초래하여 수산업의 피해를 유발할 수 있다(강원연구원, 2017). 이에 국립수산과학원, 기상청, 국립해양조사원 등 유관기관에서는 정선해양 수온 관측 및 해수순환모델을 이용하여 혼합층의 분석을 수행하고 있으나 격자 구축 및 초기·경계장 설정의 한계가 존재하여 정밀하고 정확한 혼합층 분석에는 어려움이 있다. 이에 본 연구에서는 비정형격자를 사용하여 격자 구축에 제약이 없는 SCHISM (Semi-implicit Cross-scale Hydroscience Integrated System Model)을 이용하여 우리나라 연안해역의 계절변화 및 기후변동성에 따른 혼합층 두께의 변화를 검토하고자 한다. 연구대상지는 서해·동해·남해를 포함한 우리나라 전체 연안 해역(위도: 32°N ~ 39°N, 경도: 124°E ~ 132°E)으로 선정하였으며, 격자크기 100 ~ 3,000 m인 삼각격자로 격자를 구축하였다. 혼합층을 분석하기 위하여 수직격자 층은 50층으로 SZ(Sigma Z coordinate system)좌표계를 사용하였다. 초기·경계장은 FES(Finite Element Solution)2014, HYCOM(Hybrid Coordinate Ocean Model) 및 대기모델 결과를 이용하여 설정하였다. 수치모형 검증을 위하여 수온관측소에서 수심별 측정한 수온 값과 SCHISM 결과 값을 비교하였고, 상대오차가 약 10% 이내로 나타나 모형의 정확도를 확인하였다. 최종적으로 해수면 상승 및 해수온 상승 시나리오를 고려하여 계절별 연안해역의 혼합층 두께의 변화 양상에 대하여 검토하였다. 향후에는 보다 정밀한 대기모델과의 혼합모형 구축 및 다양한 수심 별 관측자료를 활용한다면 실무에서 적용 가능한 혼합층 분석 및 수산업 피해 발생 지역에 대한 피해저감 대책 수립이 가능할 것으로 판단된다.

  • PDF

A Study on the Comparison of Injection Rate Measurement by the Bosch`s Method and the Zeuch`s Method (Bosch법과 Zeuch법에 의한 분사율 , 측정의 비교연구)

  • Ra, Jin-Hong;Kim, Jun-Hyo;An, Su-Gil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.1
    • /
    • pp.65-75
    • /
    • 1990
  • There have been many methods for measuring the injection rate of diesel engines, but the results of them are not always identical and the reason for the discordance is not clear. Besides, a single shot injection equipment has been used for the fuel spray and the combustion research of diesel engines, but the results of experiment using the equipment don't apply to a volleyed shot injection of real engines. This paper investigates the merits and faults of the Bosch's method and the Zeuch's method, at the same, this paper also compares the injection rates of single shot inject rates of single shot injection and a volleyed shot injected by the Bosch's method. the results are summarized as follows: (1) The measurement error of the Bosch's method is about $\pm$1%, therefore, its accuracy is reliable. (2) By the Bosch's method, as the speed and the load of fuel pump increase, the injection rate becomes higher, on the contrary, the injection period(ms) shortens as the speed increases and the load decreases. (3) In this experiment, the injection rate of a single shot injection is lower than that of a volleyed shot injection under the same conditions. (4) The bulk modulus of elasticity using the Zeuch's method increases in proportion to the back pressure. (5) The Zeuch's method is less accurate than the Bosch's method.

  • PDF

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.

마그네트론 스퍼터링법을 이용하여 증착한 Sn doped IZO 박막의 열전 특성

  • Byeon, Ja-Yeong;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.253-253
    • /
    • 2016
  • 최근 세계적으로 대체 에너지는 중요한 이슈가 되고 있으며 그 중 열전 재료는 유망한 에너지 기술로서 주목 받고 있다. 특히 고 직접화 전자 소자의 발열 문제를 해결하기 위해, 소형화와 정밀 온도 제어가 가능한 박막형 열전 소자에 연구가 주목 받고 있다. 박막형 열전소자 중 산화물 반도체계에 대한 연구가 활발히 진행되고 있으며, 이러한 산화물 반도체계 중 In2O3는 BiTe, PbTe 등의 기존의 재료에 비해 독성이 낮을 뿐만 아니라 내 산화성 및 고온에서 열적 안정성이 우수하여 고온에서 적용 불가능한 금속계 열전 재료의 한계를 극복 할 수 있다는 장점을 가진다. 우수한 성능 가장 낮은 캐리어 밀도를 가지기 때문에 의 열전 재료는 높은 전기 전도도 및 제백 계수 그리고 낮은 열전도도 특성을 가져야만 한다. IZO:Sn(Zn 10 wt.%, Sn 800 ppm) 박막의 경우, 높은 전기 전도성을 가지면서 비정질 구조를 가진다. 이와 같이 비정질 구조를 가지는 박막 열전 재료는 격자에 의한 열 전도도가 낮기 때문에 결정질 구조에 비해 전체 열 전도도 값이 낮을 것으로 기대된다. 따라서 높은 전기 전도도를 가지면서 동시에 낮은 열 전도도를 가지게 되어 우수한 열전 특성을 가질 것이라 예상된다. 이러한 특성을 바탕으로 본 연구에서는 비정질 구조를 갖는 Zn와 미량의 Sn을 동시에 첨가한 In2O3박막의 전기적 특성및 열전 특성을 관찰하고자 한다. 본 연구에서는 magnetron sputtering법으로 IZO:Sn(Zn 10 wt.%, Sn 800 ppm) 타깃을 이용하여 기판 가열없이 DC Power 70 W, 작업 압력 0.7 Pa으로 SiO2 기판 위에 $400{\pm}20nm$ 두께의 박막을 증착하였다. 이러한 공정으로 만들어진 박막은 대기 중 후 열처리를 각각의 200, 300, 400, 500, $600^{\circ}C$ 온도에서 진행하였다. 박막의 미세 구조는 XRD를 통해 관찰하였다. 그리고 박막의 전기적 특성은 Hall effect measurement을 통해 측정하였고, 열전 특성은 Seebeck 상수의 측정을 통하여 평가하였다. XRD 확인 결과 RT에서 증착한 박막과 후 열처리 200, 300, 400, $500^{\circ}C$ 결과 비정질 구조를 보였고, 후열처리 $600^{\circ}C$에서는 결정의 회절 피크를 보였다. 전기적 특성의 경우, 후 열처리 온도가 증가함에 따라 전기 전도도는 감소한다. 이는 공기중의 산소가 박막에 침투하여 oxygen vacancy를 막아 캐리어 밀도가 감소한것에 기인 된 것으로 판단된다. 열전 특성의 경우 제백상수는 후 열처리 $600^{\circ}C$에서 가장 높은 제백상수를 나타낸다. 제백 상수는 수식에 따라 캐리어 밀도의 -2/3승에 비례하게 된다. 수식에 따라 후 열처리 $600^{\circ}C$에서 가장 낮은 캐리어 밀도를 가지기 때문에 가장 높은 제백 상수를 가지게 된다. 열전 성능 척도인 Power factor는 제백 상수의 제곱과 전기전도도의 곱으로 나타내는데, 후 열처리 $200^{\circ}C$에서 가장 높은 Power factor를 보인다. 이는 캐리어 밀도 감소에 따라 전기 전도도는 감소하였지만 이로 인해 제백상수는 증가하였고, 또한 캐리어 밀도 감소에 따라 이온화 불순물 산란의 감소에 의해 이동도의 증가에 의한 것으로 판단된다. 박막의 경우 기판의 영향으로 인해 열 전도도 측정이 어려워 열전 성능 지수(ZT)를 계산을 할 수 없지만, 마그네트론 스퍼터링법으로 증착한 IZO:Sn 박막은 비정질 구조를 가지므로 격자진동에 의한 열 전도도가 낮아 전체 열 전도도가 결정질에 비해 낮을 것이며 이는 높은 열전 성능 지수를 가질 것으로 예상된다.

  • PDF