Tunnel Blasting case by Combination of Electronic Detonator and Non-electric Detonator (전자뇌관과 비전기뇌관을 조합한 터널발파 시공사례)

  • Lee, Min Su;Kim, Hee Do;Lee, Hyo;Lee, Jun Won
    • Explosives and Blasting
    • /
    • v.36 no.1
    • /
    • pp.34-38
    • /
    • 2018
  • It proceed the trial test by applying blasting system with combination of electronic detonator and non-electric detonator(Supex Blasting Method) for the purpose of preventing the over-break as well as controling the blasting vibration and noisy at the site of Boseong-Imseongri railroad section ${\bigcirc}{\bigcirc}$. As a result of that, the blasting vibration and noisy was measured within the allowable standard of vibration. In conclusion, the combination of electronic detonator and non-electric detonator can not only reduce come construction cost, level of vibration and noisy but also get the prevention effect for Public resentment and minimize the rock-damage through over break control.

Control Effect of Vibration According to the Application Ratio of Electronic Detonator for Tunnel Blasting (터널발파시 전자뇌관 적용 비율에 따른 진동저감 효과 연구)

  • JongWoo Lee;TaeHyun Hwang;NamSoo Kim;KangIl Lee
    • Explosives and Blasting
    • /
    • v.42 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Through existing research and construction cases during tunnel blasting, the electronic blasting method is reported to be more effective in reducing blast vibration than the normal blasting method. However, due to the high price of electronic detonators, they are only used in some blasting sites where security objects are located nearby. Accordingly, this study performed tunnel blasting tests by adjusting the ratio of electronic and non-electronic detonators. And through the research results, the reduction effect of blasting vibration according to the detonator ratio was evaluated. The research results showed that the reduction effect of blast vibration was greatest when 100% electronic detonator was applied. In addition, when more than 52% of the electronic detonator was applied, it was found that the reduction effect was similar to the reduction effect when 100% of the detonator was used.

A case study on the reduction of Blasting vibration using EDD in tunnel (터널에서 전자뇌관을 이용한 발파진동 저감 기술 사례)

  • Yoon, Ji-Sun;Lee, Jin-Moo;Cho, Young-Gon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.433-441
    • /
    • 2004
  • 국내 발파 현장에서 사용되고 있는 폭약류에 강력한 폭굉력을 충분하게 발휘하기 위해서는 뇌관(Blasting cap, Detonator)의 역할이 중요하다. 그리고 이 뇌관의 정밀성에 따라 발파 효율의 차이가 있게된다. 초기의 도화선 및 공업뇌관에서 시작하여 현재 정밀성 면에서는 MS(Milli Second)뇌관의 경우 20ms또는 25ms의 정밀한 시차로 순차적으로 기폭함으로써 발파효과의 극대화와 소음 및 진동제어에 큰 효과를 이루었으나, 최근 개발된 진자뇌관의 경우 자체 IC회로를 내징하여 $1{\sim}2ms$의 초정밀시차(오차범위 $0.1{\sim}0.2ms$이내)의 구현이 가능해짐에 따라 이를 적절히 조합하여 설계함으로써 각종 제어발파, 파쇄도 향상, 암손상영역 저감 등의 효과에 대해 국외에서 연구가 진행되고 있는 것으로 알려지고 있다. 그러나 우리나라와 같이 도심지 발파 및 터널이나 노천 현장 근거리에 보안물건이 위치해 있어 진동제어가 절실히 필요한 상황에서 진동제어에 효과가 있는 것으로 알려진 전자뇌관에 대한 연구가 이루어지고 있지 않은 상황에서 본 연구는 앞으로 이루어질 전사뇌관에 대한 수많은 연구에 기초자료를 제공하고자 실시하였다. 본 연구에서는 이를 위해 국내에서 최초로 2003년 9월 23일 강원도 양구 지역읜 00터널에 전자뇌관을 이용한 시험발파를 실시하였고, 발파에 의한 진동 등을 조사하여 그 효율성을 검토하였다. 이를 위해 전자뇌관의 특성과 장점을 최대한 살리기 위하여 각공을 발파하는 방식, 즉 1지발에 1공을 발파하는 방식을 채택하고 비전기 뇌관과 전자뇌관으로 설계를 하여 각각의 발파효율을 비교하여 보았다. 그 결과 발파신동의 경우 비전기뇌관을 이용하여 1공씩을 1지발로 발파를 한 경우에는 18${\sim}$56%의 진동저감 효과가 있었고, 번 설계에 의해 진해오딘 발파에 비하여는 최대 70% 이상의 진동저감 효과가 있는 것으로 나타났다.