• Title/Summary/Keyword: 전자 밀도

Search Result 1,926, Processing Time 0.032 seconds

A STUDY OF THE IONOSPHERIC ELECTRON MEASUREMENT ON THE MEDIUM-SIZED SCIENTIFIC ROCKET , KSR-II (중형과학로켓, KSR-II를 이용한 이온층 전자 밀도 및 온도 분포 측정에 관한 연구)

  • Lee, Jae-Jin;Kim, Jhoon;Lee, Soo-Jin;Min, Kyoung-Wook;Pyo, You-Surn;Cho, Gwang-Rae;Rhee, Hwang-Jae
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.401-415
    • /
    • 1998
  • This paper reports the results obtained from the Langmuir probe (LP) and Electron Temperature Probe (ETP) experiments on the sounding rocket KSR-II (Korean Scientific Rocket - II) which was launched on Jun 11, 1998 at 10:00 KST from Tae-An peninsula (37$^{\circ}$ N, 126$^{\circ}$ E). The instruments successfully measured the electron density, electron temperature, and the floating potential at altitudes of 73km to 130km. While the electron temperature measurement is not easy in this region, since the temperature is very low and the contamination effect of the probe may give rise to a problem, we were able to obtain a reasonable electron temperature profile by employing two independent methods, the pulse modulated Langmuir Probe and Electron Temperature Probe. The preliminary results show that electron density increases sharply at about 90km, and forms a peak at 102km. The density profile is roughly consistent with IRI (International Reference Ionosphere)95-model or PIM (Parameterized Ionospheric Model) results except that the peak density appears at 110km in the model and model electron density is slightly lower than the observed one. Electron temperature obtained from ETP fluctuates between 200$^{\circ}$K and 700$^{\circ}$K, an effect presumably coming from the wakes developed by LP, and it tends to increase with the altitude, which is consistent with the LP results.

  • PDF

Inductively Coupled $Ar/Cl_2$ Plasma Analysis with Quadrupole Mass Spectrometer (QMS) (사중극자 질량분석기(QMS)를 이용한 $Ar/Cl_2$ 유도결합 플라즈마 분석)

  • Kim, Jong-Gyu;Kim, Gwan-Ha;Lee, Cheol-In;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.41-43
    • /
    • 2005
  • $Cl_2$ 플라즈마에 있어서 Ar 가스의 첨가에 의한 효과를 보기 위해 Ar 첨가 비율 rf 전력, 반응로 압력을 변화시켜가며 그 에너지와 질량을 분석하였다. Ar 첨가 비율에 따른 각 입자들의 질량 분석을 통해서, Ar의 비율이 80% 일 때 물리적, 화학적 반응이 최대가 되는 것을 확인하였다. 또한 Ar 첨가 비율에 따른 각 이온들의 에너지 분석을 통해, Ar 가스의 첨가에 의해 $Cl^+$$Cl_2^+$ 이온들의 이온 선속은 증가하나 그 에너지가 감소하는 것을 확인하였다. 반응로 압력과 rf 전력의 제어를 통해 이온 전류밀도, 이온 에너지와 전자온도를 제어 할 수 있음을 확인하였고, Ar 첨가 비율을 변화시키면서 전자 밀도 분포 함수의 변화를 관찰하여 이를 통해 Ar 비율에 따른 이온화 비율과 전자 온도, 밀도 등의 관계를 확인하였다.

  • PDF

전력 공급 방식에 따른 유도 결합 플라즈마 특성 변화 연구

  • Kim, Hyeon-Jun;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.521-521
    • /
    • 2012
  • 공정용 유도 결합 플라즈마에서 강자성체 페라이트를 이용하여 평형전력 공급 변압기를 사용하여 안정적인 고밀도 플라즈마 발생원 개발에 관한 연구를 수행하였다. 실험에서는2개의 평형전력 공급 변압기를 이중 구조 안테나에 설치하였다. 20-100 mTorr 압력 범위의 아르곤 기체에 30-150 W범위의 전력을 인가하여 반응용기의 중앙에서 부유 탐침법을 이용하여 플라즈마 밀도와 전자 온도를 측정하였다. 동일한 압력과 전력이 인가되었을 때, 평형전력 공급 변압기의 연결 유무에 따른 플라즈마 밀도를 비교하였으며, 본 연구에서 제시한 플라즈마 발생원에서의 플라즈마 밀도가 더욱 높음을 보였다. 또한 전자 온도와 부유 전위는 평행전력 공급방식을 이용한 플라즈마 발생원이 상대적으로 낮은 값을 가졌다. 이는 플라즈마 전위의 감소를 나타내며, 챔버 벽으로 빠져나가는 이온과 전자의 손실이 줄어들었음을 알 수 있다.

  • PDF

연속 방출광 스펙트럼을 이용한 대기압 플라즈마의 전자온도 및 전자밀도 측정

  • Park, Sang-Hu;Choe, Won-Ho;Mun, Se-Yeon;Park, Jae-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.243.2-243.2
    • /
    • 2014
  • 기존의 저압 플라즈마에 비해 여러 장점을 가지는 중간압력 플라즈마 및 대기압 플라즈마는 수년전부터 많은 관심을 받고 있으며 다양한 응용분야에서 활발히 이용되고 있다. 기초과학으로서의 플라즈마 측면뿐만 아니라 플라즈마 응용의 결과들은 플라즈마의 특성에 따라 좌우되므로 플라즈마 진단 역시 최근 플라즈마 연구에 중요한 부분을 차지하고 있다. 일반적으로 플라즈마 내의 모든 화학적 반응 및 물리적 반응에 있어 전자가 결정적인 역할을 하기 때문에 플라즈마 내의 전자의 정보를 대표하는 지표인 전자온도($n_e$) 및 전자밀도($T_e$)의 측정이 중요하다. 본 연구에서는 대기압 플라즈마에서 중성원자와 전자의 상호작용에 의한 연속 방출광을 자외선-가시광 영역에서 측정하고, 이를 기반으로 $n_e$$T_e$를 측정하였다. 높은 압력에서 불완전 전리된 플라즈마는 이온화율이 낮고 중성원자의 밀도가 이온밀도보다 훨씬 높기 때문에 중성 제동복사(Neutral bremsstrahlung)의 방사도를 이용한 ne 및 Te의 측정이 가능하다. 특히 아르곤 대기압 플라즈마에서 측정된 연속 방출광 스펙트럼의 자외선 영역(280~450 nm)에서는 중성 제동복사에 의한 연속 방출광뿐만 아니라 수소분자에 의한 dissociative 연속 방출광이 함께 존재하는 것이 확인되어 최종적으로 두 연속 방출광을 고려하여 정확한 ne 및 Te를 측정할 수 있었다. 대기압 아르곤 축전결합방전에서 입력전력에 따라 전자온도는 2.5 eV로 유지되었으며, 전자밀도는 $(0.7-1.1){\times}10^{12}cm^{-3}$ 범위에서 $j_d{\propto}n_e{\propto}P_{rf}$ 관계를 따르며 변화하는 것이 관찰되었다.

  • PDF

TWO DIMENSIONAL SIMULATION OF BEAM INJECTION INTO NEUTRAL PLASMA (Beam 전자와 중성 Plasma 사이의 상호작용에 관한 2차원적 수치계산)

  • 선종호;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.7 no.2
    • /
    • pp.113-123
    • /
    • 1990
  • Two dimensional electrostatic model was used to investigate the interactions between beam electron and neutral plasma. It was found that results heavily depend on the beam density. When the beam electron density is lower than the ambient plasma beam density, many beam electrons exhibit vortex structure through beam-plasma interactions and can propagate into the ambient plasma easily from the injection area. On the other hand, when the beam density larget than that of the neutral ambient plasma, it was found that most of the beam electrons constitute return current and ion with much larger mass than that of the electron can be accelerated according to the magnetic field strength. Furthermore, as external field strength varies, it was found that propagation and interaction of the beam can show large dependence on it.

  • PDF

Density Profile Evaluation of Needle-punched Carbon/Carbon Composites Nozzle Throat by the Computed Tomography (전산화 단층촬영에 의한 니들펀칭 탄소/탄소 복합재료 노즐 목삽입재의 밀도 분포 평가)

  • Kim Dong-Ryun;Yun Nam-Gyun;Lee Jin-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.1
    • /
    • pp.44-53
    • /
    • 2006
  • In this study, the non-destructive computed tomography was adopted to observe the density profile of the needle-punched Carbon/Carbon(C/C) composites nozzle throat. The density profile of C/C was evaluated within ${\pm}0.01g/cm^3$ with 98.74% confidence when the correction of the image and high signal-to-noise ratio were achieved by the optimization of the beam hardening, the electrical noise and the scattered X-ray. The density variation of C/C with the computed tomography was in good agreement with the results obtained by the water immersion method and the observation with scanning electron microscope.

유도 결합형 플라즈마 공정조건 변화에 따른 플라즈마 방전과 전자기장 시뮬레이션의 비교

  • Kim, U-Jae;Jo, Tae-Hun;Park, Hye-Jin;Choe, Jin-U;Lee, Ye-Seul;Hwang, Sang-Hyeok;Yun, Myeong-Su;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.214.2-214.2
    • /
    • 2016
  • 플라즈마 공정은 공정의 미세화, 저온화의 필요성 때문에 반도체 및 태양전지 분야 등 여러 분야에서 널리 쓰이고 있으며 그 중요성은 점점 더 커져가고 있다. 그러나 플라즈마를 사용하는 공정에서 공정조건의 미세한 변화에 따라서 플라즈마 특성이 크게 바뀌어 공정조건에 따른 공정 결과의 예측을 어렵게 한다. 따라서 플라즈마를 이용하는 공정에 있어서 다양한 변수의 복합적인 상호작용을 고려하여 공정 결과를 예상 할 수 있는 시뮬레이션에 대한 연구가 요구되고 있다. 본 연구에서는 유도 결합형 플라즈마 발생 장치에서 공정조건에 따른 플라즈마 밀도 분포 변화를 전자기장 시뮬레이션을 통해 예상해보았으며, 시뮬레이션 결과를 실제 방전 상황에서 DLP(Double Langmuir Probe)로 측정한 값과 비교하여 플라즈마 밀도 분포와 전자기장 시뮬레이션의 정확성을 검토하였다.

  • PDF

광방사 세기비를 이용한 공정 플라즈마의 변수 진단

  • Lee, Yeong-Gwang;O, Se-Jin;Lee, Jae-Won;Hwang, Hye-Ju;Lee, Hui-Jin;Kim, Yu-Sin;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.149-149
    • /
    • 2011
  • 아르곤 기체의 방사세기 또는 그 세기 비는 플라즈마 공정 진단에서 일반적으로 사용된다. 본 실험에서는 100 mTorr 압력 조건하의 유도결합 플라즈마(13.56 MHz)에서 E-H 모드 전이 영역, rf 바이어스(12.5 MHz) 전력 인가 및 N2 혼합 시 단순화한 충돌-방사 모델에 기초한 광방사 세기비 방법을 적용하여 플라즈마 변수를 진단하였다. 개발 프로그램 기반의 분광기를 사용하여 아르곤 기체의 특정 파장(750.4, 751.5 그리고 811.5 nm)들을 관측하였고, 동일한 조건하에서 정전 탐침법으을 이용하여 전자 에너지 분포함수의 변화도 측정 하였다. 맥스웰 전자 에너지 분포를 가정하는 일반적인 경우와 비교하여 볼 때 실제적인 전자 에너지 분포함수의 측정은 전자의 가열 메커니즘에 대한 상세한 정보를 제공함과 동시에 플라즈마 재흡수에 대한 보정을 가능하게 해준다. 광방사 세기비법에 의해 측정된 결과에 의하면, 750.4 nm/751.5 nm는 높은 에너지(>13.08 eV)의 전자들의 유효 전자온도에 대한 정보를 나타내는 반면 811.5 nm/750.4 nm는 아르곤 준안정 준위 밀도(1s5)에 대한 정보를 제공하게 된다. 수행된 실험 조건하에서, 측정된 준안정 준위 밀도는 E-H 모드 전이 영역에서 최대값을 나타내었고 바이어스 전압 및 N2 기체 혼합 비율이 증가함에 따라 감소하는 결과를 얻었다. 유효 전자온도의 경우 광방사 세기비법과 정전 탐침법 모두 같은 결과를 보여 주었는데, E-H 모드 전이 영역에서는 전자온도는 거의 일정하였고 바이어스 전압 및 N2 기체 혼합 비율이 증가함에 따라 전자온도는 증가하였다. 이러한 실험 결과는 방전 모드 전이, 바이어스 인가 그리고 혼합 기체 사용하는 공정 플라즈마를 이해하는데 있어 이들 변수의 진단이 중요한 요소임을 보여준다.

  • PDF

The Dependence of CT Scanning Parameters on CT Number to Physical Density Conversion for CT Image Based Radiation Treatment Planning System (CT 영상기반 방사선치료계획시스템을 위한 CT수 대 물리적 밀도 변환에 관한 CT 스캐닝 매개변수의 의존성)

  • Baek, Min Gyu;Kim, Jong Eon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.501-508
    • /
    • 2017
  • The dependence of CT scanning parameters on the CT number to physical density conversion from the CT image of CT and CBCT electron density phantom acquired by the CT scanner using in radiotherapy were analyzed by experiment. The CT numbers were independent of the tube current product exposure time, slice thickness, filter of image reconstruction, field of view and volume of phantom. But the CT numbers were dependent on the tube voltage and cross section of phantom. As a result, for physical density range above 0, the maximum CT number difference observed at the tube voltage between 90 and 120 kVp was 27%, and the maximum CT number difference observed between CT body and head electron density phantom was 15%.

해양음향 토모그래피 기술

  • 나정열
    • The Magazine of the IEIE
    • /
    • v.31 no.6
    • /
    • pp.96-109
    • /
    • 2004
  • 해수의 물리적 성질은 수온, 염분 그리고 밀도 등으로 특성 지워지며 이러한 특성들의 시공간적인 분포 파악은 해수의 유동, 해양-대기 상호작용 및 해수자원 분포 파악 등에 필수적인 요소로 해양학 연구의 기본 관측 항목이 된다.(중략)

  • PDF