• Title/Summary/Keyword: 전자화기록

Search Result 4, Processing Time 0.016 seconds

A Study on the Legal Concept and the Scope of Public Records (공공기록의 개념 및 범위에 관한 논의)

  • Kyungnam Lee
    • Journal of the Korean Society for information Management
    • /
    • v.40 no.1
    • /
    • pp.95-119
    • /
    • 2023
  • Public institutions defining the legal scope of records management are a prerequisite to ensure the accountability and public's right to know. In this study, the requirements essential for determining the legal scope of the concept of public records were identified. For this, the concept of policies and the scope of public records which were prescribed by current laws such as the Public Records Management Act, Electronic Government Act, and Framework Act on Electronic Documents and Transactions were analyzed by this study. Furthermore, by examining both domestic and foreign cases on the legal competence of evidence of digitized records, institutional supplementary points were proposed.

Analysis of Transmission Characteristics for Cascaded WDM Optical Add / Drop Multiplexers with Crosstalk , ASE Noise , and Extinction Ratio (WDM 광 분기 / 결합 시스템에서의 누화 , ASE 잡음 , 소광비가 전송특성에 미치는 영향분석)

  • Lee, Sang-Rok;Seo, Wan-Seok;Lee, Sung-Un
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.1-8
    • /
    • 1999
  • We analyze the transmission performance of WDM system based on cascaded optical add/drop multiplexers. The considered factors degrading the performance in this paper include the intra-channel corosstalk caused from space switches and demultiplexers/multiplexers, the amplified spontaneous emission noise, and the extinction ratio. To ensure the power penalty within 1dB, the extinction ration more than 13dB, the switch corosstalk less than 39dB, and the demultiplexer/multiplexer crosstalk less than 20dB are required. Under the assumption of switch corosstalk less than 30dB, performance degradation due to the ASE noise is dominant compared to the crosstalk. With the fixed decision threshold in an optical receiver, the maximum number of cascaded nodes reduces to a half compared to the case of the optimum decision threshold.

  • PDF

Design and Implementation of 10Gigabit Ethernet System with IPC and Frame MUX/DEMUX Architecture (10기가비트 이더넷 인터페이스를 위한 프레임 다중화기/역다중화기와 IPC를 갖는 10기가비트 이더넷 시스템의 설계 및 구현)

  • 조규인;김유진;정해원;조경록
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.5
    • /
    • pp.27-36
    • /
    • 2004
  • In this paper, we propose the ethernet Inter-Processor Communication (IPC) network architecture and 10gigabit ethernet frame multiplex/demultiplexer architecture for the edge switch system based on Linux that has 10 Gigabit Ethernet (10Gigabit Ethernet) port with 72Gbps capacities. we discuss the ethernet IPC with ethernet switch and we propose design and implementation of ethernet Inter-Processor Communication (IPC) network architecture and multiple gigabit ethernet frame rnultiplexing/demultiplexing scheme to handle 10gigabit ethernet frame instead of using 10gigabit network processor. And then ethernet Inter-Processor Communication (IPC) network architecture and 10gigabit ethernet frame MUX/DMUX architecture is designed verified and implemented.

The Effect of Crosstalk and Loss on the Scaliability and Transmission Performance of Optical Cross-Connect Nodes (광상호분배기 노드에서 누화와 손실을 고려한 전송성능 및 확장성 분석)

  • Lee, Sang-Rok;Seo, Wan-Seok;Yoon, Byeong-Ho;Lee, Sung-Un;Lee, Jong-Hyun
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.11
    • /
    • pp.15-21
    • /
    • 1999
  • The scalability of optical cross-connect nodes is analyzed based on the limiting factor of transmission performance. The limiting factors considered are ASE noise accumulation and gain saturation in the optical amplifiers, and crosstalk in both wavelength multiplexers/demultiplexers and optical switches. When the wavelength multiplexer/demultiplexers crosstalk is lower than 25dB, Power Penalty is below 1dB for the cascaded transmission of 10 nodes with 4 input/output ports. When 10Gbps signals are transmitted through nodes with 4 and 16 input/output Ports, performance degradation due to switch crosstalk is dominant compared to that due to ASE noise accumulation if the switch crosstalk is larger than 30dB and 45dB, respectively. For the single stage transmission of 10Gbps signal with 21dB fiber link loss, the maximum loss of optical cross-connect nodes must be under 34dB to achieve the BER of $10^{-12}$.

  • PDF