• Title/Summary/Keyword: 전자파영향

Search Result 827, Processing Time 0.021 seconds

Implementation of Sonar Bearing Accuracy Measurement Equipment with Parallax Error and Time Delay Error Correction (관측위치오차와 시간지연오차를 보정하는 소나방위정확도 측정 장비 구현)

  • Kim, Sung-Duk;Kim, Do-Young;Park, Gyu-Tae;Shin, Kee-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2019
  • Sonar bearing accuracy is the correspondence between the target orientation predicted by sonar and actual target orientation, and is obtained from measurements. However, when measuring sonar bearing accuracy, many errors are included in the results because they are made at sea, where complex and diverse environmental factors are applied. In particular, parallax error caused by the difference between the position of the GPS receiver and the sonar sensor, and the time delay error generated between the speed of underwater sound waves and the speed of electromagnetic waves in the air have a great influence on the accuracy. Correcting these parallax errors and time delay errors without an automated tool is a laborious task. Therefore, in this study, we propose a sonar bearing accuracy measurement equipment with parallax error and time delay error correction. The tests were carried out through simulation data and real data. As a result of the test it was confirmed that the parallax error and time delay error were systematically corrected so that 51.7% for simulation data and more than 18.5% for real data. The proposed method is expected to improve the efficiency and accuracy of sonar system detection performance verification in the future.

수삼 내부의 자기공명영상 특성

  • 손재룡;이강진;최동수;김기영;강석원;최규홍
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.151-152
    • /
    • 2003
  • 최근 NMR, MRI, x-선 등 전자파의 기술이 발전되면서 이들을 이용하여 내부품질을 검출하는 보다진보된 연구가 수행되고 있다. 관련 연구로는 자기공명영상을 이용하여 내공수삼 및 정상수삼의 내부를 촬영하여 T$_1$, T$_2$의 값을 측정하여 내부조직의 이상유무를 추정하였고, 또한 MRI에 의해 수삼의 내부품질 뿐만 아니라 연근 판정 가능성을 검토하는 등 많은 연구가 수행되고있다. 이 연구에서는 MRI 시스템을 이용하여 수삼의 내부단면 영상을 획득하여 내부결함 유무를 검출하고, 또한 동일한 수삼을 대상으로 홍삼 제조 후 내부품질의 변화 특성을 조사하고자 수행하였다. 공시재료는 충북 음성에 있는 인삼연초연구원에서 4~6년 근 된 수삼을 이용하였고, 시험 장비로는 국내 MRI 생산 전문 업체인 ISOL Tech. Co.에서 개발한 의료용 장비인 CHORUS 1.5T(자속밀도 1.5 Tesla)를 이용하였다. 슬라이스 두께/간격은 5mn/5mn, 촬영 단면수는 15장/시료, 영상영역(FOV)은 180mmx90mm, image size는 256$\times$128 pixels 그리고 TR/TE는 각각의 이완상수별로 500/13(Tl), 4,000/63(T2) 및 2,200/21(Pd)에 대한 단면영상을 얻었다. 5개의 수삼을 동시에 뇌두에서 뿌리 쪽으로 MR 단면영상을 획득하였다. 이완상수 T$_1$, T$_2$, Pd에 대해서 MR 영상을 획득하였으며, 총 15장의 단면 영상 중 내부 상태를 가장 잘 식별 할 수 있는 영상을 조사한 결과 T$_1$과 Pd에서 촬영한 영상에서는 내부상태가 잘 나타났으나, T$_2$에서 얻은 영상은 영상의 손실이 많이 발생되었다. 한편, T$_1$에 대해서 뇌두에서 뿌리쪽으로 가면서 각 위치에 따라 수삼 내부의 부패된 영상이 나타나 이에 대한 판정은 가능한 것으로 나타났다. 2000년도와 2001년도에 각각 수확.저장된 수삼을 부위별로 단면영상을 MRI로 측정하고, 그 시료를 인삼연초연구원(음성시험장)에서 홍삼으로 제조한 후 수삼 상태에서의 내부품질과 홍삼으로 제조된 후의 내부품질 변화를 조사하였다. 총 20본의 수삼을 MRI 시스템으로 영상을 획득하였고, 모든 시료에 대해서 내부조직의 상태를 관찰하였다. 수삼의 수분함량은 뇌두로부터 1cm부위를 절단하여 조사하였고, 수삼조직은 절단시 단면의 달관 조사에 의한 성적이며 홍삼품질은 제조삼의 조직상태를 절단하여 육안판별로 검사하였다. 총 20본의 수삼 중 정상은 16본 이었고, 이들은 홍삼으로 제조된 후 내공 내백 등이 혼재되어 나타났으며 정상수삼이 정상홍삼으로 나타난 경우는 5본이었고, 내백은 5본, 내공은 6본으로 조사되었다. 또한 수삼에서 4본은 썩은 부위가 포함되어있는 수삼이었는데 홍삼으로 제조되었을 때 3본은 내백으로 되었고 1 본은 수삼에서 썩은 부위가 1/4정도로 미미해서 홍삼 제조시 정상으로 나타났다. 일반적으로 홍삼 제조시 내공의 발생은 제조공정에서 나타나는 경우가 많으며, 내백의 경우는 홍삼으로 가공되면서 발생하는 경우가 있고, 인삼이 성장될 때 부분적인 영양상태의 불충분이나 기후 등에 따른 영향을 받을 수 있기 때문에 앞으로 이에 대한 많은 연구가 이루어져야할 것으로 판단된다.

  • PDF

Design of Communication Board for Communication Network of Nuclear Safety Class Control Equipment (원자력 안전등급 제어기기의 통신망을 위한 통신보드 설계)

  • Lee, Dongil;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.185-191
    • /
    • 2015
  • This paper suggest the safety class communication board in order to design the safety network of the nuclear safety class controller. The reactor protection system use the digitized networks because from analog system to digital system. The communication board shall be provided to pass the required performance and test of the safety class in the digital network used in the nuclear safety class. Communication protocol is composed of physical layer(PHY), data link layer(MAC: Medium Access Control), the application layer in the OSI 7 layer only. The data link layer data package for the cyber security has changed. CRC32 were used for data quality and the using one way communication, not requests and not responses for receiving data, does not affect the nuclear safety system. It has been designed in accordance with requirements, design, verification and procedure for the approving the nuclear safety class. For hardware verification such as electromagnetic test, aging test, inspection, burn-in test, seismic test and environmental test in was performed. FPGA firmware to verify compliance with the life-cycle of IEEE 1074 was performed by the component testing and integration testing.

Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material (자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.481-489
    • /
    • 2018
  • In MRI examination, when irradiating the human body with RF Pulse to acquire images, the portion of the irradiated RF Pulse energy is absorded into the human body, and this will affect the temperature of the human body. If a metal is inserted into the human body even if the same RF Pulse energy is applied, the SAR value increases and the body temperature changes due to the increase in the electromagnetic wave conductivity of the metal. So we measure and compared with the change in the SAR and temperature in the implant material of the dental implant in Brain MRI examinations. Experiments were performed on a human head model using a 64MHz and 128 MHz RF Pulse frequency generated by a 3.0 Tesla MRI apparatus. And then changed material of dental implants to Titanium and $Al_2O_3$. Using the XFDTD program, the changes in SAR and body temperature around the head were examined. When with Titanium the SAR value and temperature of Brain increased, but with $Al_2O_3$ showed lower SAR and temperature as compared with Titanium. The dental implants were low in SAR and temperature of the head in $Al_2O_3$, which are electrical insulators with low electrical conductivity, compared to Titanium, which is an electrical conductor. It is necessary to study the biologic effect of patient with brain MRI when titanium dental implant material is inserted in the future. Because the maximum value of SAR is much higher than the limit when dental implant material is Titanium. In addition, it is necessary to use an implant of $Al_2O_3$ material to reduce the SAR value and temperature of the Brain in Brain MRI examination.

Study on the Environmental Factors and Symptoms of VDT Syndrome (VDT 증후군의 환경적 요인과 증상에 대한 연구)

  • Jeong, Seunghui;Lee, Seon Young;Eu, Sun Mi;Kim, Douk-Hoon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2009
  • Purpose: Recently incidence of VDT syndrome has gradually increased as extensive use of computers. VDT syndrome reported by VDT workers include musculoskeletal disorder, neuropsychiatric disoders and eye symptoms such as eye strain, tired eyes, irritation and blurred vision. The environmental factors of VDT syndrome include electromagnetic waves, size, brightness and lighting of computer screen, height of a monitor and a worktable, working hours, kind of task, distance between screen and workers, indoor humidity and temperature, indoor air contamination and ventilation. In this study, we investigated the environmental factors related to body symptoms and health effects included in VDT syndrome. Methods: Study subjects were total 120 persons (54 male, 66 female) with age from 19 to 28. We surveyed the body symptoms and physical discomfort when doing an activity in a short distance such as reading book or paper, computer work. The questionnaire included main body symptoms, self-consciousness symptoms of eye, satisfaction of working environment, pain of the wrist when using keyboard and mouse. Results: Most of people (70%) felt physical pain from long time work of computer, paper, electrical apparatus. They mainly complained pain of neck and low back (57.1%), eye (45.2%) and head (31%). With the environmental factors, 78.3% of the subjects complaint pain of eye from inappropriate illumination. Most of the symptoms included 'eye fatigue'(38.3%), 'dryness of eye'(31.9%) and 'blurred vision'(23.7%). Subjects in this study complained discomfort of their chairs and most of them experienced pain in the wrist when using keyboard or mouse. Conclusions: When people use electrical apparatus or work with paper, people would get their eye fatigue and feeling of physical fatigue because of not harmonizing various environmental factors such as light, space, posture, worktable with theirselves. Therefore, workers should develop preventive method such as self-control of adequate break time to avoid fatigue while VDT work. Work environment should be changed to ergonomic design for optimal visual environment to prevent musculoskeletal disorder through constant research.

  • PDF

Related factors on musculoskeletal symptoms in selected Korean female office and blue-collar workers (우리나라 일부 사무직과 생산직 여성근로자에서 근골격계 자각증상과 관련요인)

  • Lee, Kyung-Jae;Han, Sung-Hyun;Ahn, Yeon-Soon;Hwang, Jung-Ho;Kim, Joo-Ja
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.289-299
    • /
    • 2007
  • Objectives : To investigate the related factors on musculoskeletal symptoms among Korean female workers. Methods : A total of 1,875 female workers (1,002 office workers and 873 blue-collar workers) was analyzed. They were randomly selected among female workers by cluster sampling and interviewed by well trained interviewer, who filled out a structured questionnaire on the musculoskeletal symptoms. Other factors such as general and occupational characteristics including workplace location, employment condition, work duration, and working condition were also investigated. Results : Current smokers and drinkers were significantly more common in blue-collar workers than in office workers. Those working full time were significantly more common in blue-collar workers than in office workers. Those working over 8 hours per day were also popular in office workers than in blue-collar workers. Subjective musculoskeletal symptoms were significantly higher in the type of work including excessive repetitive work, work using awkward stretching hand upwards, work using repetitive wrist movements, static work using awkward hand posture, and heavy manual lifting and handling works. The mean score of the symptoms were significantly higher in blue-collar than in office workers. The significantly different working factors between two groups were work duration, employment condition and daily work hours. Conclusion : We suggest that the type of work including awkward and repetitive works as well as job type may be one of the most important factors related to musculoskeletal symptoms of female workers in the workplace. Preventive strategy will be needed to prevent the negative impact on health status of working women in the workplace.

Dynamic Behavior of Reactor Internals under Safe Shutdown Earthquake (안전정기지진하의 원자로내부구조물 거동분석)

  • 김일곤
    • Computational Structural Engineering
    • /
    • v.7 no.3
    • /
    • pp.95-103
    • /
    • 1994
  • The safety related components in the nuclear power plant should be designed to withstand the seismic load. Among these components the integrity of reactor internals under earthquake load is important in stand points of safety and economics, because these are classified to Seismic Class I components. So far the modelling methods of reactor internals have been investigated by many authors. In this paper, the dynamic behaviour of reactor internals of Yong Gwang 1&2 nuclear power plants under SSE(Safe Shutdown Earthquake) load is analyzed by using of the simpled Global Beam Model. For this, as a first step, the characteristic analysis of reactor internal components are performed by using of the finite element code ANSYS. And the Global Beam Model for reactor internals which includes beam elements, nonlinear impact springs which have gaps in upper and lower positions, and hydrodynamical couplings which simulate the fluid-filled cylinders of reactor vessel and core barrel structures is established. And for the exciting external force the response spectrum which is applied to reactor support is converted to the time history input. With this excitation and the model the dynamic behaviour of reactor internals is obtained. As the results, the structural integrity of reactor internal components under seismic excitation is verified and the input for the detailed duel assembly series model could be obtained. And the simplicity and effectiveness of Global Beam Model and the economics of the explicit Runge-Kutta-Gills algorithm in impact problem of high frequency interface components are confirmed.

  • PDF