• Title/Summary/Keyword: 전자결합장치

Search Result 246, Processing Time 0.033 seconds

Human-Powered Generator designed for Sustainable Driving (고출력 지속이 가능한 인체 구동 방식의 자가 발전기 개발)

  • Lim, Yoon-Ho;Yang, Yoonseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.135-142
    • /
    • 2015
  • Human-powered self-generating devices have been attractive with its operation characteristic independent from outer environment such as weather condition and wind speed. However, conventional self-generators have low electric power output due to their weakly-coupled electromagnetic structure. More importantly, rotary crank motion which is usually adopted by conventional self-generator to generate electricity requires specific skeletal muscles to maintain large torque circular motion and consequently, causes fatigue on those muscles before it can generate enough amount of electricity for any practical application. Without improvement in electric power output and usability, the human-powered self-generator could not be used in everyday life. This study aims to develop a human-powered self-generator which realized a strong electromagnetic coupling in a closed-loop tubular structure (hula-hoop shape) for easy and steady long-term driving as well as larger electric output. The performance and usability of the developed human-powered generator is verified through experimental comparison with a commercial one. Additionally, human workload which is a key element of a human-powered generator but not often considered elsewhere, is estimated based on metabolic energy expenditure measured respiratory gas analyzer. Further study will focus on output and portability enhancement, which can contribute to the continuous power supply of mobile equipments.

Relationship between maximum bite force and facial skeletal pattern (최대 교합력과 안면 골격 형태에 관한 연구)

  • Choi, Won-Cheul;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.437-451
    • /
    • 2003
  • The purpose of this study was to measure maximum bite force and to investigate its relationship with anteroposterior, vertical, and transverse facial skeletal measurements. From among the dental students at the College of Dentistry, forty subjects (26 male and 14 female) were selected. With two sets of strain gauge, maximum bite force at the right and left first molars and anterior teeth was measured in the morning and afternoon. After taking lateral and posteroanterior cephalograms, fifty and nineteen variables were evaluated, respectively Paired t-tests and an independent t-test were done and correlation coefficients were obtained. 1. The maximum bite force at the first molars was $68.0\pm13.9kg$. in males and $55.6\pm10.5kg$ in females (p<0.05) while the force at the anterior teeth was $8.4\pm4.9kg\;and\;1.1\pm3.4kg$ respectively (p<0.05). 2. Some tendency for a greater value of maximum bite force at the preferred side was observed but not statistically significant (p>0.05). 3. Significant difference was observed between the strong bite force group and the weak bite force group in some cephalometric and other measurements (p<0.05). N-S-Ar, S-Ar-Go, FH-Hl, IMPA and MMO showed a significant difference in posterior maximum bite force (P). N-S-Ar and FH-H1 also showed a significant difference in anterior maximum bite force (A). 4. Several cephalometric variables showed some correlation with maximum bite force (p<0.05). N-S-Ar, S-Ar-Go, UGA, FH-H6, FH-H1, body weight and MMO were significantly correlated with posterior maximum bite force (P). Go-Me, P-1 and IMPA were significantly correlated with anterior maximum bite force (A).

A Scheme for Reuse of Residual Energy in a Multi-cell Battery System (다중전지 시스템에서 잔류 에너지의 재활용 방법)

  • Yun, Woong-Jin;Baek, Je-In
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.21-27
    • /
    • 2009
  • As portable electronic systems being used more often, it becomes a more important issue to lengthen the lifetime of the power battery of the system, for instance, by developing batteries of a higher efficiency. A simple as well as practical method to lengthen the lifetime is to use multiple batteries that are connected in parallel. But in this paper we present a new idea in using multiple batteries, with which the residual energy of the battery can be used in the sense of recycling. The idea is based on a usual phenomenon that a battery cell that has been used until its voltage has dropped below a reference level may still have some residual energy, due to which the voltage can recover when the cell takes a rest for a while. As a practical realization scheme of this idea, a multi-cell configuration method with a cell selection switch is introduced, and its feasibility has been examined by performing experimental observations on the behavior of battery discharge. It has been found that the lifetime of an Alkaline primary battery cell can be lengthened approximately by one or two hours with the proposed method.

Characteristic Feature of Inductively Coupled Plasma Atomic Emission Spectrometer/Shielding System and Evaluation of Its Applicability to Analysis of Radioactive Materials (유도 결합 플라스마 원자방출분광기/차폐 시스템의 특성 및 방사성 물질 분석에 대한 적용성 평가)

  • Lee, Chang Heon;Suh, Moo Yul;Choi, Kae Chun;Park, Yang Soon;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.474-483
    • /
    • 2000
  • An inductively coupled plasma atomic emission spectrometer/shielding system was specially designed and built for the analysis of radioactive materials. Both of an inductively coupled plasma source and a sample transfer system to be contacted with radioactive materials was installed in a stainless steel glove box. In terms of analytical capability and radiation safety, characteristic feature of the system was investigated. Its applicability to the determination of fission products and corrosion products in the radioactive materials such as spent fuel dissolver solution and the primary coolant of nuclear power reactors was evaluated. In the concentration range $0.01-0.1mgL^{-1}$, the relative standard deviation was found to be less than 5%.

  • PDF

Autoradiographic Verification of Transdermal Penetration of Oleic Acid-conjugated Peptide Nanosomes (자가방사법에 의한 올레산이 결합된 펩타이드의 피부침투 확인)

  • Lee, Kyung-Eun;Jung, Min-Kyo;Eum, Jai-Hoon;Jung, Se-Hui;Ha, Kwon-Soo;Park, Jeong-Hae;Lee, Jin-Sung;Han, Sung-Sik;Choe, Myeon
    • Applied Microscopy
    • /
    • v.40 no.4
    • /
    • pp.185-191
    • /
    • 2010
  • Short peptides are potentially effective materials as cosmeceuticals, but their delivery across the skin can be problematic due to the ionic nature of peptides and the structure of the skin. For short peptide to be utilized as cosmeceuticals, its ability to penetrate the skin must be altered. In this study, we conjugated the widely used procollagen type I signal peptide, KTTKS, with oleic acid to improve the lipophilic properties of the peptide, and used the oleic acid-conjugated peptides to construct cosmeceutical nanosomes. Then we examined the penetration of cosmeceutical nanosomes prepared from isotope-labeled peptide into the skin after transdermal application using autoradiography. Because of its hydrophilic property of penta-peptide, the penta-peptide itself was not able to be penetrated through the stratum corneum of the skin. In contrast, nanosomes made from olecic acid conjugated penta-peptide were able to be penetrated through the stratum corneum effectively. Autoradiography showed the precise penetration points to dermal layer, demonstrating the appropriateness of this method for clarifying the mechanism of penetration of transdermal delivery systems.

Analysis of PCI Cable Effects in HEMP Conducted Disturbance (HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석)

  • Jang, Tae-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.772-780
    • /
    • 2013
  • The high-altitude electromagnetic pulse(HEMP) conducted environment and the HEMP radiated environment are established as the consequences of a high-altitude nuclear explosion. The IEC 61000-2-10, the international standard, defines the HEMP conducted environment. The IEC 61000-5-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. The IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. The IEC 61000-4-24:1997 mainly describes the measurement method of small protective components. However, it does not provide the measurement method for a combination filter of a protective component and a filter which is widely used in recent. It is important to consider the characteristic of the measurement setup parameters like thickness and length of the cable and its height above ground plane etc. in establishing measurement setup because HEMP conducted disturbances include the frequency spectrum below 50 MHz. This paper deals with the optimized measurement method, considering the frequency spectrum of HEMP conducted disturbance, current waveform, and analyzing the effects of cables existing in the measurement setup.

Application of Temperature Gradient Gel Electrophoresis To cAMP Receptor Protein (온도 기울기 전기영동장치의 CAMP 수용성 단백질에 응용)

  • Gang, Jong-Back;Cho, Hyun-Young
    • Journal of Life Science
    • /
    • v.14 no.2
    • /
    • pp.309-314
    • /
    • 2004
  • Cyclic AMP receptor protein (CRP) is involved in the transcriptional regulation of more than 100 genes in E. coli. CRP dimer is converted into active form via the sequential conformation change of cAMP binding pocket, hinge region and HTH DNA binding motif by binding of cAMP. The temperature gradient gel electrophoresis (TGGE) was applied to CRP protein to know whether it was an efficient technique to study the conformational transitions and the thermal stability. TGGE showed the unfolding process of wild-type and S83G CRP proteins with the temperature gradient set from 29 to 71$^{\circ}C$ on nondenaturing polyacrylamide gel. Melting temperature (Tm) was 57$\pm$1 and 55$\pm$1$^{\circ}C$ for wild-type and S83G CRP, respectively in acidic buffer[89.8 mM Glycine and 24 mM Boric acid (pH 5.8)].

Condition Monitoring and Fault Diagnosis System of Rotating Machinery (회전기기의 상태감시 및 결함탐지 시스템)

  • Jeong, Sung-Hak;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.819-820
    • /
    • 2016
  • Electrical power distribution is consists of high voltage, low voltage and motor control center(MCC). Motor control centers involves turning the motor on and off, it is configured electronic over current relay to detect a motor overcurrent flows. Existing electronic over current relay detects electrical fault such as overcurrent, undercurrent, phase sequence, negative sequence current, current unbalance and earth fault. However, it is difficult to detect mechanical fault such as locked rotor, motor stator and rotor and bearing fault. In this paper, we propose a condition monitoring and fault diagnosis system for electrical and mechanical fault detection of rotating machinery. The proposed system is designed with signal input and control part, system interface part and data acquisition board for condition monitoring and fault diagnosis, it was possible to detect electrical fault and mechanical fault through measurement and control of insulation resistance, locked rotor, MC counter and bearing temperature.

  • PDF

Design and Implementation of Prototype model of Vehicle speed automatic variable control System (차량속도 자동화 가변 시스템의 프로트 타입 모델 설계 및 구현)

  • Choi, Sung-Jai
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.47-54
    • /
    • 2019
  • In the worldwide, The issue comes up which is the danger of car accidents from climate-change effects. We are considering about various types of speed limit signs for setting restricts to high-speed vehicles. South Korea has 4 seasons in the land. At Summer or Winter seasons have heavy rains and fogs or snow, In these seasons need to enforce speed limit laws or methods to prevent car collision. But South korea is using stationary speed limiters that is not enough to proof against rear-end car accidents in these climates. In this paper shows the necessity of independent LED speed limits display to reduce car accidents. And explaining the prototype model which is a combination of rain sensor and wiper systems. This model is independently changed the speed limits to 50%, 80%, 100% of standards by raindrops and snowflake. Also it is freely setting speed limits on each places anywhere it settled in. Visual effects of the model as being speed-down of vehicles helps to prevent rear-ending car accidents and traffic beforehand.

Receiving Characteristics of an Electronic Steering System according to the Change of the Coil Structure (전자식 조향 장치의 코일 구조 변화에 따른 수신 특성)

  • Park, Jae-Hong;Jeong, Gyu-Won;Ryu, Seung-Ryul;Kim, Eun-Ha;Choi, Han-Ol;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.868-874
    • /
    • 2011
  • In this paper, a new structure to improve the resolution of an inductive torque sensor is proposed. The new coupling structure and the change of number of turns for the receiving coil increase the resolution of the torque sensor. Because this torque sensor has non-contact points, it has no abrasion at the contact point, and is very durable. Also, the torque sensor has less variation due to vibration or strain, and it has a good EMC(Electromagnetic Compatibility) and thermal characteristics.