• Title/Summary/Keyword: 전원설비

Search Result 709, Processing Time 0.026 seconds

A Study on the Optimization of Power Supply Equipment for Plate Mill Plant in Steelworks (제철소 후판공장 전원공급설비의 용량 최적화에 관한 연구)

  • Ko, Hyun-Ok;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1300-1305
    • /
    • 2014
  • In this paper, we suggest an optimization method which can save about 5[%] of the cost though the optimizing of configuration and capacity for the facility. To achieve this goal, we compared the design data of the power, motor and drive system with the actual operation data of the plate mill plant in K-Steelworks. Therefore we measured the actual loading data by facilities considering the operating conditions of the plate mill plant in K-Steelworks, after that analyzed these data. In addition, we review the optimal capacity for transformer, switchgear and drive, and also reconfigured the electrical room and power single line diagram through the validation of motor data by equipment and the confirmation of process data considering the load characteristics. Consequently, the optimization method of capacity for the facilities shall have effectiveness in building new plate mill plant to further reduce costs at future.

Development of 10,000N linear motor LCD Stocker system with CPTS (비접촉 전원장치를 적용한 LCD stocker용 10,000N급 선형전동기 응용시스템 기술개발)

  • Kim, T.J.;Rim, G.H.;Kang, D.H.;Cho, J.G.;Cho, S.J.;Cho, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2057-2058
    • /
    • 2006
  • 선형 전동기는 일반 회전기를 펼친 상태로 유도기, 전동기, 직류기 및 기타 특수 전동기로 분류하며 그 원리는 회전형 전동기와 같다. 직선 운동을 필요로 하는 시스템에서 기계적 변환 기구를 사용하지 않고 직접 직선 운동을 얻을 수 있으므로 향후 자동화 기기, 교통수단, 산업용 기기 등에 많은 수요를 창출할 수 있는 전동기이다. 또한 선형 전동기는 일반 회전형 전동기에 비해 스크류, 체인, 기어 시스템 등의 기계적인 변환장치가 없이 선형 구동력을 직접 발생시키므로 청정을 필요로 하는 환경에서 회전형에 비해 절대적으로 우세하다. 그러나 이상과 같은 장점을 지닌 선형 전동기를 실제 시스템에 적용하기 위해서는 속도의 저하에 따른 저 출력, 저 효율 및 고 가격과 같은 문제들을 우선적으로 해결해야 한다. 본 논문에서는 이 선형 전동기 기술이 적용되는 차세대 LCD 공정 자동화설비인 10,000N급 Stocker System에 적용되는 핵심기술과 기술개발 동향에 대한 소개를 하고자 한다.

  • PDF

A Study on Modular Multi-level Converter Applied to AC Eletric Railroad Substation (교류 철도 급전변전소의 모듈형 멀티레벨 컨버터 적용 모델링 연구)

  • Hyun, Byungsoo;Shin, Seungkwon;Kim, Hyungchul;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1605-1606
    • /
    • 2015
  • 전기철도차량은 매 순간마다 이동하는 대용량 단상부하로, 전력계통 측면에서 부하의 특성이나, 계통구성의 형태 및 제반현상이 일반 3상 전력계통과 상이한 특성을 지닌다. 이와 같이 3상 전력계통으로 부터 단상 교류로 변환하여 전기차를 운행하는 경우에는 3상 전원측 PCC(Point of Common Coupling)에 불평형을 일으켜, 역상전류를 발생시킨다. 현재는 이를 최소화하기 위해서 종래부터 사용 되어온 스코트 결선 변압기를 사용하고 있다. 하지만 특성상 두 개의 단상 시스템에 걸리는 부하량 및 역율이 동일하지 않을 경우 여전히 3상 전압불평형이 발생된다. 이에 대한 근본적인 대책으로는 급전시스템 재구성 또는 전력 설비 증설 및 보상장치의 적용을 들 수 있으나, 최근에는 전력전자 기술의 발달로 IGBT(Insulated Gate Bipolar Transistor) 소자를 이용한 BTB(Back To Back) 방식의 컨버터를 활용한 사례가 연구되고 있다. 본 논문에서는 전력계통과 전기철도의 연계 목적으로 3상-단상 BTB 모듈형 멀티레벨 컨버터 (Modular Multi-level Conveter, MMC)를 이용한 전기철도 급전 시스템의 기본구조를 제안하고, Mathworks사의 MATLAB Simulink tool를 이용하여 시뮬레이션을 통해 MMC시스템을 검토하고자 한다.

  • PDF

A Study on the Operational Characteristics of PFC at Instantaneous Power Interrupt (순시 정전 시 역률 개선 회로의 동작 특성에 관한 연구)

  • 이해돈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.390-396
    • /
    • 2004
  • Recently, there have been Increasing demands for high power factor and low harmonic distortion in the current drawn from utility. The harmonic limits imposed by international standards. It need the PFC techniques in order to reduce line current harmonics and comply with the standards. The average current control method that is the most proper PFC control method in a switching power supply of middle and high power has been used mostly to PFC control method. However, the switching device of PFC circuit has frequently destructed at power return after instantaneous power interrupt. Therefore, this paper have verified the cause of this problems and proposed the solution through simulation and experiment

A study on S/W development for Pneumatic target device to Complex Rotation using Wireless (무선통신망을 이용한 복합구동 공압표적장치 운영 S/W 개발에 관한 연구)

  • Ahn, Woo-Young;Jung, Jin-Young
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.01a
    • /
    • pp.87-90
    • /
    • 2016
  • 현재 한국 군부대에서 사용되고 있는 표적구동장치는 1990년도에 만들어진 재래식 장비로서 노후화 및 부품교체 난제로 인하여 지속적인 시스템의 오류와 이에 따른 장비 가동률 저하 등의 문제로 실전적인 사격 훈련이 어렵다. 이에 본 연구에서는 보다 효과적인 훈련을 진행하고자 복합 구동 표적장치를 개발하였다. 본 연구에서 개발된 복합 구동 표적장치는 Up-down, Swing, Turn, Rotary 방식의 표적 구동을 원격으로 제어하여 다양한 사격 및 전술 훈련 적용 가능하도록 제작되었으며, 또한 사격진행 통제 결과를 통제관 혼자서 총괄 운용이 가능한 모니터링 시스템을 구축하였다. 그리고 현재 각 부대에 설치되어 있는 표적구동장치 및 전술훈련 컨트롤러는 유선을 통한 시리얼통신 및 중앙 분배식 전원공급시스템으로서 운영설비를 위하여 과도한 배관배선 등의 공사가 별도로 시행되어야 하는 문제점이 있다. 따라서 본 연구에서는 이러한 문제점을 해결할 수 있도록 무선 통신시스템방식을 적용하여 다양한 훈련지역에 호환 적용될 수 있는 장비를 개발함으로써 훈련장 시설건립을 위한 부담을 줄이고, 운영의 극대화를 확보할 수 있도록 경제적, 기술적 효과를 추구하였다.

  • PDF

Oxidation Behavior of STS Series at High -Temperature/Stagnation/Oxidizer-Rich Environment (고온/정체/산화제 과잉 환경에서 STS 계열의 산화 거동)

  • Shin, Donghae;Lee, Seongmin;Lee, Hijune;Ko, Youngsung;Kim, Seonjin;So, Younseok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.843-848
    • /
    • 2017
  • Metal exposed to high temperature/high pressure/oxidizer-rich environment may cause rapid oxidation(ignition and combustion). In this study, a DC power supply test system that controls the temperature of specimen by supplying power to the specimen was constructed and after simulating the high temperature/stagnation/oxidizer-rich environment, the metal oxidation and ignition of STS series metal materials were evaluated. As a result, we was confirmed that the deformation (discoloration) of the selected material, the change in the surface roughness and the peeling of the metal surface were observed, and that the weight and the specimen thickness were changed. The most oxidized specimen was STS 304 and the less oxidized specimen was XM-19.

  • PDF

3D Printed Electronics Research Trend (3차원 인쇄기술을 이용한 전자소자 연구 동향)

  • Park, Yea-Seol;Lee Ju-Yong;Kang, Seung-Kyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.2
    • /
    • pp.1-12
    • /
    • 2021
  • 3D printing, which designs product in three dimensions, draws attention as a technology that will lead the future for it dramatically shortens time for production without assembly, no matter how complex the structure is. The paper studies the latest researches of 3D-printed electronics and introduces papers studied electronics components, power supply, circuit interconnection and 3D-printed PCBs' applications. 3D-printed electronics showed possibility to simplify facilities and personalize electric devices by providing one-stop printing process of electronic components, soldering, stacking, and even encapsulation.

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.

The Site Installation Test of Single-Phase MJ81 Switch Point Machine Localization (단상 MJ81 전기선로전환기 국산품의 현장설치시험)

  • Baek, Jong-Hyen;Kim, Yong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3632-3637
    • /
    • 2009
  • In this paper, we describe the performance results of the field installation test which is required to practicalize the single-phase MJ81 Switch Point Machine. This product has passed the certified test through performance improvement of driving parts in order to use 3 phase MJ81 Switch Point Machine, which is localized by taking over technology from Alstom and Cogifer when constructing Seoul-Busan rapid-transit railway, without change of the electrical equipment at track-side in domestic existing lines which single-phase 220V is used. KRRI and Samsung SDS have localized the single-phase MJ81 Switch Point Machine to improve the speed and safety of the conventional lines through the existing railway technology development project. For practicalization of this, we should, however, verify the performance through not only field installation test in real lines but also interface test with the interlocking. In this paper we verify the practicality of the domestic single-phase MJ81 Switch Point Machine through analysis on the performance result of the field installation test as well as the research contents for this test. Thereby, in Feb 2009 we have received an order from the Korea Rail Network Authority and are currently installing the single-phase MJ81 Switch Point Machine.

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.