• Title/Summary/Keyword: 전원설비

Search Result 710, Processing Time 0.024 seconds

Development of 460[V]/225[A]/50[kA] Contact System in Current Limiting MCCB using an estimation and analysis method for the interrupting capability (차단성능 평가해석기법을 적용한 강자계 구동방식의 460[V]/225[A]/50[kA]급 한류형 MCCB 소호부 개발)

  • 최영길;박찬교
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.78-84
    • /
    • 2004
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widely used in power distribution systems. In the paper, it has been investigated how much interrupting capability is improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), especially contacts and arc runner. Prior to the interrupting testing, it is necessary for the optimum design tc analyze electromagnetic forces on the contact system generated by current and flux density. This paper presents both our computational analysis and test results on contact system in MCCB

Analysis of the Actuator Winding to a Frequency Characteristic based on Energy Conversion Theory (에너지 변환 이론에 의한 액추에이터 권선부의 주파수 특성 해석에 관한 연구)

  • 김양호;이해경;황석영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.83-87
    • /
    • 2004
  • In this paper, an electrical equivalent circuit is derived by solving system equations. A frequency characteristics graph is calculated and the characteristics curve of the linear Actuator Model System are simulated by the Matlab program The frequency characteristics of a linear actuator are analyzed on the structure of the linear Actuator Model System This paper proposed and analyzed the linear Actuator Model(LAM) by using Matlab program with linear actuator was verified computer simulation based on the energy conversion theory.

A Study on Outage Restoration Guide Including Load Cutoff in Distribution System (부하차단을 포함한 배전계통 정전복구방안에 관한 연구)

  • 김세호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.98-104
    • /
    • 2004
  • This paper represents the fast and efficient load transfer guide for fault or outage restoration in distribution system. For restoration guide, system trace is performed to reverse direction(source side) from tie breaker in tree-structured distribution network. Search space and breaker's combinational number for restoration guide are greatly reduced. It is proposed the load transfer method including first stage restoration(single load transfer, double load transfer, triple load transfer), second stage restoration(transferring load to neighboring feeder in order to expand the capacity margin) and load cutoff guide. The proposed method can be easily applied to primary customer restoration, multi-fault recovery and distribution automation system.

A Study of Single Phase Hysteresis Current Control Using Reference Current Slope for Reducing Switching Loss (스위칭 손실 저감을 위한 기준전류 기울기를 이용한 단상 히스테리시스 전류 제어에 관한 연구)

  • Hong, Sun-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.150-155
    • /
    • 2009
  • Hysteresis current regulator has been used widely because of its simple principle and structure. However, when the current band width is too narrow or the applied voltage is relatively too high, the switching frequency increases abruptly and it makes large amount of heat. In this study, for single phase current control, the hysteresis current control is executed by adding 0 mode state and comparing the slope of the current reference, which decreases the switching frequency so much and make the current control much stable. These were proved with computer simulations.

Protection ability for lightning surge according to the grounding system of low voltage power systems (저압 전원계통 접지방식별 뇌서지보호성능)

  • Lee, Bok-Hee;Lee, Gyu-Sun;Choi, Jong-Hyuk;Yoo, Yang-Woo;Kim, Dong-Sung;Kang, Sung-Man;Ann, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.343-346
    • /
    • 2009
  • The grounding system of low voltage power systems is TT grounding system in Korea. In order to follow the international standard, TN grounding system is adopted. However, the performance of grounding systems has not been evaluated. This paper deals with the experimental results of protection ability of grounding system when lightning surge invades to the neutral line of low voltage power system. As a result, the TT grounding system is most frail for the lightning surge and it does not protect the electrical devices. On the other hand, the TN grounding system perfectly protects the electrical equipment and prevents the electric shock for human through the equipotential bonding. In case of TN system with supplement grounding, it is very important to lower the supplement grounding resistance to protect the electrical equipment and electric shock for human.

  • PDF

A Study on High Precision and High Stability Digital Magnet Power Supply Using Second Order Delta-Sigma modulation (2차 델타 시그마 변조기법을 이용한 고 정밀 및 고 안정 디지털 전자석 전원 장치에 관한 연구)

  • Kim, Kum-Su;Jang, Kil-Jin;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.69-80
    • /
    • 2015
  • This paper is writing about developing magnet power supply. It is very important for power supply to obtain output current in high precision and high stability. As a switching noise and a power noise are the cause of disrupting the stability of output current, to remove these at the front end, low pass filter with 300Hz cutoff frequency is designed and placed. And also to minimize switching noise of the current into magnet and to stop abrupt fluctuations, output filter should be designed, when doing this, we design it by considering load has high value inductance. As power supply demands the stability of less than 5ppm, high precision 24bit(300nV/bit) analog digital converter is needed. As resolving power of 24bit(300nV/bit) analog digital converter is high, it is also very important to design the input stage of analog digital converter. To remove input noise, 4th order low pass filter is composed. Due to the limitation of clock, to minimize quantization error between 15bit DPWM and output of ADC having 24bit resolving power, ${\Sigma}-{\Delta}$ modulation is used and bit contracted DPWM is constituted. And before implementing, to maximize efficiency, simulink is used.

Dual Current Control Scheme of a Grid-connected Inverter for Power Quality Improvement in Distributed Generation Systems (분산 전원 시스템의 전력품질 향상을 위한 계통연계 인버터의 이중 전류제어 기법)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.33-41
    • /
    • 2015
  • To improve the power quality of distributed generation (DG) systems even in the presence of distorted grid condition, dual current control scheme of a grid-connected inverter is proposed. The proposed current control scheme is achieved by decomposing the inverter state equations into the fundamental and harmonic components. The derived models are employed to design dual current controllers. The conventional PI decoupling current controller is used in the fundamental model to control the main power flow in DG systems. At the same time, the predictive control is applied in the harmonic model to suppress undesired harmonic currents to zero quickly. To decompose the voltage inputs and state variables into the fundamental and harmonic components, the fourth order band pass filter (BPF) is designed in the discrete-time domain for a digital implementation. For experimental verification, 2kVA prototype of a grid-connected inverter has been constructed using digital signal processor (DSP) TMS320F28335. The effectiveness of the proposed strategy is demonstrated through comparative simulation and experimental results.

Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines (특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성)

  • Shim, Seo-Hyun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.

A Study of Demand and Effects on Power System of Electric Vehicles (전기자동차의 전력수요 및 전력계통에의 영향 분석)

  • Kim, Hong-Gyun;Hwang, Gab-Chul;Rho, Jang-Hyun;Park, Jong-Wan;Park, Eung-Rae;Kim, Tae-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.113_114
    • /
    • 2009
  • 우리나라 전기자동차의 잠재 전력수요는 최대부하 측면에서 분석해보면 2008년말 현재 우리나라 자동차 16,794,287대를 전력부하로 환산해보면 1,887,017MW로서 우리나라 발전용량(70,353MW)의 약27배로 나타난다. 다행히도 전기자동차는 비동시 부하이며 최대부하로 충전하지는 않으므로 동시에 그만한 최대전력수요가 필요한 것은 아니다. 그러므로 연간 공급가능한 전기에너지(GWh)를 밸리 필링(Vally Filling;여유 심야전력) 전력량으로 구해보면 약 50,151GWh/년이고, 전기자동차의 에너지 필요용량을 계산해보면 46,587GWh/년이 된다. 이 결과는 전기자동차용 에너지양이 기설 발전설비로 공급가능한 밸리 필링 전력량의 93%로서 전기자동차의 수요를 적당한 시간대로 유도하면 현재의 발전설비 용량으로도 전기자동차에 에너지 공급이 가능하다는 것을 의미한다. 그러나 수도권의 자동차가 45.9%를 차지하고 있어 향후 수도권의 전력공급을 위한 전력 수송의 병목현상인 북상조류의 문제는 심화될 위험이 있다. 하지만 전기자동차의 축전지를 계통에 연계하여 분산전원으로 운영한다면 계통의 피크전력과 예비전력, 주파수 조정 등에 이점을 가져올 수도 있을 것이다.

  • PDF

A Study on the Development of a Silencer and Noise Reduce for M.Tr Room (주변압기실의 소음저감 및 소음기 개발에 관한 연구)

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.111-118
    • /
    • 2006
  • Relatively high noise emitted from Transformers of in-door-substation in urban area has become the target of public complaints and the frequency is on the rise in these days due to an extension of transformer installations and new establishment of substations. The noise consist of harmonics of a specific frequency of the twice of the electricity frequency(60[Hz]), which is hard to control by using the general sound proofing techniques. In this work, several effective methods were discussed for reducing the noise from a transformer, which is transmitted through explosion preventing shutter and air tunnels. By applying to the actual site, the effects of the methods were verified.