• Title/Summary/Keyword: 전열 특성

Search Result 338, Processing Time 0.029 seconds

Rate Augmentation of Exothermic Hydration in the CaO Packed Bed (CaO 충전층의 수화발열반응 촉진)

  • Chung, Soo-Yull;Kim, Jong-Shik
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.91-101
    • /
    • 1994
  • Heat release characteristics of a CaO packed bed reactor which is used for a chemical heat storage device has been studied. We employed Cu-plate fins to release the heat of reaction of the CaO packed bed inside the reactor fast and effectively. Two-dimensional analysis of unsteady state heat flow inside the bed was performed as a function of time and under various conditions of the Cu-plates. It is noted that the time required to release the heat of reaction with Cu fins is reduced more than twice fast compared to that without Cu fins. That was largely dependent upon the number of Cu-plate, as well.

  • PDF

Evaluation of Eddy Current Signals from the Inner Wall Axial Cracks of Steam Generator Tubes (증기발생기 전열관의 내면 축방향 균열에 대한 ECT 특성 평가)

  • Choi, Myung-Sik;Hur, Do-Haeng;Lee, Doek-Hyun;Park, Jung-Am;Han, Jung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.501-509
    • /
    • 2001
  • For the enhancement of ECT reliability on the primary water stress corrosion cracks of nuclear steam generator tubes, of which the occurrence is on the increase, it is important to comprehend the signal characteristics on crack morphology and to select an appropriate probe type. In this paper, the sizing accuracy and the detectability for the inner wall axial cracks of tubes were quantitatively evaluated using the following specimens: the electric discharge machined notches and the corrosion cracks which were developed on the operating steam generator tubes. The difference of eddy current signal characteristics between pancake and axial coil were also Investigated. The results obtained from this study provide a useful information for more precise evaluation on the inner wall axial tracks oi stram generator tubes.

  • PDF

A Study on Fire Performance and Heat Transfer of HPC Column with Fiber-Cocktail in ISO Fire under Loading Condition (표준화재 재하조건 Fiber Cocktail을 혼입한 고강도 콘크리트 기둥의 전열 특성 및 화재 거동에 관한 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Jeon, Hyun-Kyu;Youm, Kwang-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.29-39
    • /
    • 2010
  • In this study, experimental test and numerical analysis were conducted to investigate the heat transfer characteristics and fiber performance of high strength concrete. The fire characteristics of the high strength concrete that couldn't be obtained through the test due to specific requirements and restrictions were forecast using numerical analysis approach. The outcome from the numerical analysis and the test were compared to verify and improve the reliability of the analysis. A numerical analysis of 80 and 100 MPa high strength concrete cases were carried out to identify the heat transfer characteristics and fire behavior using software, ABACUS (V6.8) From the results of verification experiment, a 25~55% level of beam shrinkage reduction was observed compared to the concrete without Fiber-Cocktail, indicating the improved fire resistance performance, which appeared to be attributable to the function of Fiber-Cocktail that was able to control the heat transfer characteristics and ultimately result in enhancing the fire resistance performance.

질소 이온빔을 이용한 인코넬690의 기계적 특성 변화 연구

  • 홍인석;황용석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.118-122
    • /
    • 1997
  • 차세대 원자력발전소 증기발생기 전열관 재료로 채택된 니켈기저합금으로 기존 전열관 재료인 인코넬600에 비해 고온 고압 조건에서 응력부식균열에 강한 장점을 가진 합금인 인코넬690 시료에 최대 에너지 120 keV의 질소 이온빔을 조사하여 이 재료의 기계적 특성 변화를 관측하였다. 특성 시험으로는 표면 경화를 관찰하기 위한 미세 경도 시험을 수행하여 미세 경도 증가를 확인하였다 아울러 표면 경화가 피로 특성에 미치는 영향을 관찰하기 위해 피로 균열 전파 시험을 수행하여 이온 주입으로 인한 표면 경화가 피로 균열 전파를 촉진시킴을 관찰하였다.

  • PDF

Heat Transfer on a Heated Flat Plate by an Impinging Round Jet Using Liquid Crystal (Liquid Crystal을 이용한 원형충돌분류의 전열특성 연구)

  • 오승묵;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1566-1574
    • /
    • 1992
  • Local heat transfer characteristics for a round air jet impinging normally on a heated flat plate were experimentally investigated. The problem parameters investigated were jet Reynolds number, Re=4000,10000, and 20000, and nozzle-to-plate spacing(L/D) of 2,6, and 10. The temperature variations on the flat uniform heat flux surface were mapped using a thermo-sensitive liquid crytal sheet. The isochromatic images corresponding to the characteristic temperature of liquid crystal were analyzed with the help of a digital image processing system. The local Nusselt number, Nu decreased rapidly in the impingement region and exhibited a similar profiles in the wall jet region independent of the nozzle-to-plate spacing L/D. In the case of large Reynolds number, heat transfer rate (Nu) was proportional to 0.5 power of the Reynolds number. For L/D=2, a secondary peak in the heat transfer rate was seen in the region of X/D=1.5~3 due to the transition from laminar to turbulent boundary layer.

The Power Spectral Density Characteristics of Lift and Drag Fluctuation on a Heat Exchanger Circular Tube (열교환 단일 원관의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.35-40
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. The present study examined the results of the previous experimental researches for the nondimensional PSD characteristics by CFD analysis and the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared from the present CFD analysis. For the previous mentioned purpose, the present CFD analysis introduced a single circular cylinder and calculated with the unsteady laminar flow over the cylinder. The characteristics of vortex shedding and lift and drag fluctuation over the cylinder was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift and drag PSD over a single circular cylinder was established from the present CFD study.

Condensing heat transfer characteristics of alternative refrigerants in small diameter tubes (세관내 대체냉매의 응축 열전달 특성)

  • 오후규;홍진우
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.5
    • /
    • pp.396-402
    • /
    • 1999
  • 1980년대부터 본격적으로 제기된 대기 환경 오염 문제로 인해서 CFCs 및 HCFCs계 냉매에 대한 대체 연구가 활발히 진행되었는데, 이와 관련한 열교환기의 고성능화, 콤팩트화 등에 관한 연구도 광범위하게 이루어지고 있다. 이중에서 특기할만 한 것은 종래의 전열관보다 관경이 대단히 적은 세관을 적용하는 경우가 있으며, 그 적응 범위도 점점 더 넓어질 전망이다. 이것은 유효전열 면적의 극대화, 난류효과의 상승, 가공성기 향상, 유연성 등 세관만이 가질 수 있는 여러 가지 전열 성능상의 장점 때문이라 생각한다.

  • PDF

A study on the flow induced vibration on a heat exchanger circular cylinder (열교환 단일 원관의 유동 유발 진동 특성에 관한 연구)

  • Ha, Ji Soo;Lee, Boo Youn;Shim, Sung Hun
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.109-114
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. The present study examined the results of the previous experimental researches for the nondimensional PSD characteristics by CFD analysis and the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared from the present CFD analysis. For the previous mentioned purpose, the present CFD analysis introduced a single circular cylinder and calculated with the unsteady laminar flow over the cylinder. The characteristics of vortex shedding and lift fluctuation over the cylinder was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift PSD over a single circular cylinder was established from the present CFD study.

The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2016
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift and drag fluctuation over the fin tube was investigated. The derived nondimensional lift PSD was compared with the results of the previous experimental studies and the characteristics of lift and drag PSD over a single fin tube was established from the present CFD study.

A Study on the Characteristics of Lift Fluctuation Power Spectral Density on a Fin Tube in the Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력 변동 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn;Shim, Sung Hun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.211-216
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift fluctuation over the fin tube was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift PSD over a single fin tube was established from the present CFD study.