• Title/Summary/Keyword: 전열계수

Search Result 117, Processing Time 0.026 seconds

Heat Flow Characteristics on Type of Heat Transfer Plate for White Smoke Reduction under Uniform Flow Condition (균일유동에서 백연저감용 전열판 형태에 대한 열유동 특성)

  • Son, Jun;Cha, Jae Min;Wang, Zhen Huan;Kwon, Young Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.591-596
    • /
    • 2016
  • Numerical analyses were performed on the heat flow characteristics of a heat transfer plate with six different shapes (basic, rectangle, triangle, wave type) to reduce the level of white smoke at a stack. In this study, to examine the heat transfer performance (heat transfer capacity, pressure drop, turbulence kinetic energy, heat transfer coefficient) on the heat transfer plates, simulations were conducted using the commercial computational fluid dynamics software, ANSYS CFX Ver.14 under uniform flow conditions. The thermal flow phenomenon in a channel with six heat transfer plates could be predicted adequately under uniform flow conditions. The heat transfer capacity, pressure drop, turbulence kinetic energy, and heat transfer coefficient were affected by the flow rate, aspect ratio and plate shape. These results provide guidelines to design an effective heat exchanger with the wave type to reduce white smoke.

An Experimental Study on Heat Transfer in the Furan Foundry Sand Fluidized Bed (Furan Foundry Sand 유동층에서 열 전달 특성에 관한 연구)

  • Park, Jong-Suen;Baek, Ko-Kil;Kim, Uen-Young;Jeon, Sung-Taek;Lee, Duck- Bong
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.105-117
    • /
    • 1995
  • Heat transfer coefficients on a single spiral coil tube in the furan foundry sand fluidized bed have been investigated. Heat transfer coefficients(ho) to an immersed single spiral coil tube were measured in the bed. The bed diameter was 0.21 m. The following quantities were varied: (l)bed temperature, (2)mean particle diameter, (3) fluidization rate, (4)the ratio of heated coil tube pitch to diameter(p/Do), and (5)the ratio of heated coil tube pitch to mean particle diameter(p/dp). In addition, the experimental values of maximum Nusselts number were compared with the values of maximum Nusselts number predicted by the existing correlations. The values of heat transfer coefficient increase with the increase in bed temperature and fluidization rate, but decrease with increase in particle diameter. An empirical formulus of maximum Nusselts number which is applicable in the furan foundry sand fluidization bed is as follows: $$Nu_{max}=1.01\;Re^{0.48}Prg^{0.4}(p/dp)^{0.28}(p/Do)^{0.05}$$.

  • PDF

Heat Transfer on a Heated Flat Plate by an Impinging Round Jet Using Liquid Crystal (Liquid Crystal을 이용한 원형충돌분류의 전열특성 연구)

  • 오승묵;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1566-1574
    • /
    • 1992
  • Local heat transfer characteristics for a round air jet impinging normally on a heated flat plate were experimentally investigated. The problem parameters investigated were jet Reynolds number, Re=4000,10000, and 20000, and nozzle-to-plate spacing(L/D) of 2,6, and 10. The temperature variations on the flat uniform heat flux surface were mapped using a thermo-sensitive liquid crytal sheet. The isochromatic images corresponding to the characteristic temperature of liquid crystal were analyzed with the help of a digital image processing system. The local Nusselt number, Nu decreased rapidly in the impingement region and exhibited a similar profiles in the wall jet region independent of the nozzle-to-plate spacing L/D. In the case of large Reynolds number, heat transfer rate (Nu) was proportional to 0.5 power of the Reynolds number. For L/D=2, a secondary peak in the heat transfer rate was seen in the region of X/D=1.5~3 due to the transition from laminar to turbulent boundary layer.

Hydrodynamic Study in the Cold CFB Reactor with 3-Cyclones (3개의 사이클론 갖는 순환유동층에서의 수력학적 특성 연구)

  • 이종민;김재성;김종진
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.57-60
    • /
    • 1999
  • 순환유동층 보일러는 연소로 (상승관: riser)내에 공기를 고속으로 주입하여 비말동반되는 고체입자를 사이클론에서 포집 하여 재주입하는 유동층을 이르는 것으로, 난류유동층(turbulent fluidized bed), 고속유동층(fast fluidized bed) 그리고 희박상 유동(dilute phase flow) 영역에서 조업이 이루어진다. 순환유동층은 비교적 높은 기체 유속에서 조업이 이루어지기 때문에 고체입자의 혼합 및 비산 그리고 재순환이 격렬하게 이루어지고, 기-고체간 접촉효율 및 전열계수가 높아 전체적인 처리량 및 효율이 좋은 장점을 가지고 있다.(중략)

  • PDF

Performance and Heat transfer Characteristics of Louver Fin-tube Heat Exchanger for Simultaneous Cooling/Heating Heat Pump (동시 냉난방 히트펌프용 루버핀-관 열교환기 성능 및 전열특성 실험연구)

  • Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1337-1342
    • /
    • 2007
  • An experimental study has been performed to investigate the performance and heat transfer characteristics of the heat exchanger for simultaneous cooling/heating heat pump. The heat transfer performance was measured using an air-enthalpy calorimeter and a constant temperature water bath, to obtain the performance evaluation and analysis of a fined tube heat exchanger. Six finned tube heat exchangers with louver fin were tested under a heating condition. Air-side heat transfer and friction were presented in terms of j-factor and f-factor. The heat transfer coefficient increased with decreasing the fin pitch, j-factor and f-factor on the fin pitch and the number of tube rows decreased with increasing Reair.

  • PDF

공조기용 열교환기

  • 윤정인
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.47-51
    • /
    • 2000
  • 최근 룸에어콘이나 패키지에어콘의 에너지 절약, 쾌척성 등에 대환 사용자나 회사로부터의 요구는 더더욱 높아지고 있다. 공조기의 중요한 구성요소 중 하나인 열교환기도 이러한 요구에 대응하여 기술개발이 계속해서 진행되고 있다. 공조용 열교환기를 설계할 때 가장 중요한 과체는 비용이냐 설치성 등의 제약조건올 만족하면서 필요한 교환열량을 달성하기 위해, 요구되는 열 전달계수(K)와 전열면적(A)의 곱인 KA값을 얼마나 확보하는가 하는 점에 있다. 그러나 이 외의 과제, 예를 들어 홴입력, 소음을 억제하기 위한 공기측 통풍저항의 감소, 증발온도에 영향을 마치는 관내압력손실의 감소 등도 중요한 과제이다. KA값 증대와 통풍저항억제를 동시에 판촉하기 위해 공조용 열교환기는 전면면적을 크게 하고 두께를 작게 하여 사용하는 것이 원칙이다. 또, 전열관의 관경도 관 둘레길이와 냉매분배성능 면에서 제약이 발생한다. 이와 같은 배경으로부터 공조용 열교환기는 판경 6~10 mm정도의 전열 관을 20~25mm길이로 배치한 핀튜브형 열교환기가 주류로 되어있다. 여기에서는 공조기에 널리 사용하고 있는 핀튜브형 열교환기에 대한 최근의 기술개발 사례를 소개하고자 한다.

  • PDF

Optimum Design of Waste Heat Boiler with Water Tube and Three Drum (3드럼 수관식 폐열보일러의 최적설계)

  • Lee, Kwan-Jong;Han, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.992-998
    • /
    • 2006
  • This study is to optimize design parameters for waste heat recovery boiler with water tube and three drum. The design optimization considered here is to find the most economic dimension of the boiler considered which results in a minimum cost in producing a unit amount of steam per given period of operation. For this purpose, optimize design have to determine what are the main parameters of affecting the total cost of producing a unit amount of steam which is comprised of manufacturing cost of the boiler, operating cost of the fan etc.

A Study on Thermal Performance Comparison between Large and Small Sized Plate Heat Exchanger (판형 열교환기 크기에 따른 전열성능 비교에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.528-534
    • /
    • 2020
  • The early development and use of plate heat exchangers (PHE) were in response to stringent statutory requirements from dairy products in the late 19th century, but PHEs were not exploited commercially until the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures and pressures, as well as large heat exchanging capacities. The development of current chevron-type corrugated heat plates has been ongoing since the oil shock in the 1970s to improve energy efficiency. The development trend of PHEs is consistent with the development of larger heat plates with better thermal efficiency, lower pressure drop, and good flow distribution. In this study, the thermal performance of small heat plates (PHE-S) and large heat plates (PHE-L) with the same plate depth and corrugation pitch were analyzed experimentally for each channel (H, M, and L type) to suggest development directions of heat plates. The test results showed that for the convectional heat transfer coefficient, the PHE-S was on average, 16.5% higher in the H type, 25% higher in the M type, and 40% higher in the L type than PHE-L. In the case of the pressure drop, the PHE-S was 19% higher in the H type, 46% higher in the M type, and 61% higher in the L type than PHE-L. These results were attributed to the differences in fluid distribution areas between the PHE-S and PHE-L, among other potential causes.

A Study on Thermal Performance of Plate Cooler for Cooling Medium Speed Engine Lubricant Oil (선박용 중속엔진 오일냉각용 판형쿨러의 전열성능에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • Plate heat exchangers(PHE) have been commercialized since the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures, higher pressures, and large heat exchanging capacities. The development trend of PHEs is consistent with heat plate developments with better thermal efficiency, lower pressure drop, and good flow distribution. The purpose of this paper is to introduce the main development processes of a plate cooler for medium-speed engine lubricant oil cooling in vessels which is in line with the development trend of PHEs and to provide its thermal performance data that were found out during experimental tests. The plate cooler in this study cannot measure the wall temperatures directly due to its structural characteristics, so the heat transfer coefficients were calculated using the modified Wilson Plot method. The water-to-water tests were first conducted experimentally to figure out the characteristics of heat transfer coefficients and pressure drops on the water side and then the water-to-oil tests followed to obtain the heat transfer coefficients on the oil side. The test results showed that heat transfer coefficients and pressure drops on both water and oil side increased with flow rates, and it was also found that all the development targets of the plate cooler in this study were achieved successfully.

Heat Transfer Enhancement by Fins in a Latent Heat Storage System Using Phase Change Material (상변화물질을 이용한 축열시스템에서 핀에 의한 열전달 촉진 연구)

  • 한승구;한귀영
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.115-122
    • /
    • 1996
  • Heat transfer characteristics of low temperature latent heat storage systems have been examined for the circular finned and unfinned tubes using Na$_2$B$_4$O$\_$7/10H$_2$O as a phase change material. In order to reduce the supercooling of PCM, 3 wt% of Na$_2$B$_4$O$\_$7/10H$_2$O was added as the nucleating agent and 2.2 wt% of acrylic acid sodium sulfate was used as the thickener. The heat storage vessel has dimension of 530 mm height, 74 mm 1.D. and inner heat transfer tube is 480 mm height and 13.5 mm O.D. Water was employed as the heat transfer fluid. During the heat recovery experiment, the heat recovery rate was affected by the flow rates and inlet temperature of heat transfer fluid. The enhancement of heat transfer by fins over the unfinned tube system was found to be negligible in the thin finned tube systems, whereas the heat transfer coefficient in the thick finned tube system is approximately 60% higher than that in the unfinned lobe system. The experimentally determined heat transfer coefficient for the unfinned tube and thick finned tube systems are 150-260 W/㎡$^{\circ}C$ and 230-530 W/㎡$^{\circ}C$, respectively. The fin efficiency based on the heat transfer coefficient and area increased by fins was found to be 0.05 and 0.26 for the thin and the thick finned tube systems.

  • PDF