New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications (대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • Yang, Seung-Uk;Choe, Gyu-Ha;Mok, Hyung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.209-215
    • /
    • 2006
  • Now, in this paper, going to present you with an Idea related to a new inverter of multi-step voltage source, that Is, the double-connected 12-step inverter with an auxiliary circuit. It possibly can be 24-step inverter with 3-phase voltage source which will enable us make full application even to medium and high power-level Motor drive, UPS, STATCOM, SVC, etc. in which the PWM method could not be employed. 24-step operation can be obtained from the link between the existing 12-step inverter and the additional auxiliary circuit in which the transformer of auxiliary circuit generates ripple voltage delivered to the inverter. Through a lot of experiments and simulations, (from which the validity of this scheme is confirmed,) we came to the conclusion that the increase of the primary winding number on transformer by 2N(N=1,2,3....) leads to the 12M-step(M=2,3,4...) inverter. The validity of the proposed scheme is confirmed by the simulated and experimental results.

A Study on Harmonics Analysis and Modelling for Distribution System (배전 시스템의 고조파 분석 및 모델링에 관한 연구)

  • Wang, Yong-Peel;Jeong, Jong-Won;Jeong, Dong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.62-68
    • /
    • 2007
  • The increasing use of power electronic equipment in distribution system has been the reason for the greater concern about a harmonic in recent time. Therefore, it is necessary for measurement and modelling to analyze a harmonic level and a transfer characteristic in distribution system. In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000-3-6. Harmonic voltage and orient were measured at the PCC of real distribution system Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current under steady-state. Harmonic transfer characteristic were investigated through a analysis of harmonic voltage and current under harmonic current source.

Design and Implementation of a Low-Noise SMPS for Distributed Control Systems (분산제어시스템을 위한 저잡음 SMPS의 설계 및 구현)

  • Cheong, Tai-Hyun;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.12 no.1
    • /
    • pp.59-64
    • /
    • 2008
  • In this paper, a new efficient SMPS has been designed and implemented. It can replace the existing product that is widely used in industry. To investigate the performance of the conventional SMPS, the output voltage changes due to variations in the input voltage and the load conditions, and the ripple and noise voltages have been measured and analyzed. As a result, it has been confirmed that the noise in the conventional SMPS is severe due to the deficiency of patterns for current. This is because the conventional SMPS draw out all outputs using one transformer and the alarm logic exists in the output path. To solve this problem, the switching frequency is increased from 17KHz to 70KHz and the current patterns are fully guaranteed by separating the alarm circuit and PWM circuit as a sub-board from the main board. Measurement results shows that the output noise of the designed SMPS decreases below 32% of the conventional SMPS noise for various test conditions, and both the line and load regulations are improved.

  • PDF

Inprovenent of the Electrical Characteristics of Transformer Oil dissolved with $SF_6 Gas$ ($SF_6 Gas$를 용해시킨 변압기 절연유의 고주파 전기 특성의 향상)

  • Jeon, Chung-Saeng
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.312-318
    • /
    • 1994
  • In this paper the breakdown and dielectric characteristics of purified transformer oil dissolved with $SF_6$ Gas are investigated with a few decade MHz frequency voltage. The results are as follows. 1) High frequency current is a approximately proportional to the square root of high frequency voltage in purified transformer oil. 2) As frequency increase breakdown voltage decrease inversely proportional to the square root of frequency and the high frequency breakdown voltage is lower about 35 percentage than that of AC 3) The breakdown voltage of high frequency has a little increase with the pressure increase of dissolved $SF_6$, Air and Ar Gas. 4) As voltage freguency increases the value of the dielectric loss tangent has increased almost exponentially and the dielectric constant ($\varepsilon$) has tended to decrease with a slope[0.6% MHz]. 5) When dissolved with $SF_6$ Gas, oil electrical characteristics has more increased about 25% than in Air or Ar gas with high voltage frequency.

  • PDF

A Study on the Development of a Remote Monitoring Equipment for Ground Fault Current by Lightning Strike (낙뢰에 의한 지락전류 원격 감시장치에 관한 연구)

  • Pyo, Se Young;Kim, Tag Yong;Kim, Kee Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.783-788
    • /
    • 2020
  • Surges generated by direct strike or induction of lightning, frequent opening and closing of power system breakers, etc. cause excessive overvoltage, which can interfere with normal operation of transformers, circuit breakers, and power equipment. In order to prevent such phenomena, this study goes further from the method of establishing countermeasures by installing lightning arresters on power equipment or lines in parallel, and furthermore, remotely checking the condition of the lightning arrester and preparing immediate countermeasures when an event occurs. The purpose of the study is to prevent damage in advance.

Optimal Design of LLC Resonant Converter with Secondary Leakage Inductance (2차측 누설 인덕턴스를 고려한 고주파 LLC 공진형 컨버터의 최적 설계)

  • Park, Hwa-Pyeong;Kim, Mina;Jung, Jeehoon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.195-196
    • /
    • 2016
  • MHz 이상의 높은 공진 주파수를 가지는 LLC 공진형 컨버터는 공진 소자의 크기가 줄어 높은 전력 밀도를 구현 가능하다. 하지만 2차측 누설 인덕턴스가 공진에 크게 영향을 미쳐 기존의 디자인 방법에 오차가 커지고 이는 효율 감소로 이어진다. 본 논문은 이를 극복하기 위해 2차측 누설 인덕턴스를 고려한 컨버터 모델을 제시하고 이의 전압 이득을 분석한다. 제안하는 모델을 사용하여 높은 효율을 위한 변압기의 자화 인덕턴스, 턴 비를 제시하고, 안정적인 컨버터 동작을 위해 2차측 다이오드 디자인 방법을 제안한다. 모든 제안하는 분석 및 디자인 방법은 1 MHz 스위칭 주파수를 가지는 240 W LLC 공진형 컨버터를 통해 검증하였다.

  • PDF

A Study of the Streaming Electrostatic Current in High Voltage - Large Power Transformer (초고압 대용량 변압기에서의 유동대전 현상에 관한 연구(전압무인가))

  • Park, Jae-Yun;Yun, Seung-Jin;Minari, Kogane;Lee, Duck-Chool;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.176-179
    • /
    • 1990
  • In this paper, the pheonmena of flowing electrification is experimently studied in the model transformer of a super high voltage transformer. The current of natural terminal which is flowed by the flowing electrification is increased according to oil flow, but according to the oil temperature the current is decreased and the direction of the current is changed.

  • PDF

Novel Reset Winding Clamped Forward Converter with Transformer Voltage Feedback Technique for Power Factor Correction (변압기 전압 되먹임방식을 이용한 고역률의 리셋권선을 갖는 새로운 포워드 컨버터)

  • Moon, Gun-Woo;Roh, Chung-Wook;Jung, Young-Seok;Lee, Jun-Young;Youn, Myung-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.348-350
    • /
    • 1996
  • A new reset winding clamped forward converter with transformer voltage feedback technique for power factor correction with a single-switch/single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF

Analysis and Implementation of Single-Stage AC/DC Converter with Magnetic Energy Feedback Technique for Power Factor Correction (역률개선을 위한 자기에너지 궤환기법의 단일전력단 AC/DC 컨버터의 해석 및 구현)

  • 문건우;오관일;전영수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.148-155
    • /
    • 1998
  • A novel single-switch, single-stage, AC/DC forward converter with transformer magnetic energy feedback technique for power factor correction is proposed. The operational principle and analysis of the proposed converter is presented. The proposed converter gives the good power factor correction, low line current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC 555-2 requirements are met satisfactorily with nearly unity power factor.

Development of a Large Scale STATCOM Using Double-Connected Multistep Inverter (이중접속방식의 멀티스? 인버터를 이용한 대용량 STATCOM의 개발)

  • Kim T.H.;Bae Y.S.;Choi S.W.;Lee W.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.31-35
    • /
    • 2003
  • 본 논문에서는 이중접속 방식의 멀티스텝 인버터를 인 용한 대용량 STATCOM에 관하여 동작원리 및 제어 방식을 기술하기로 한다. 기존의 12-스텝 인버터에 상간 변압기 및 간단한 보조회로를 이용하여 출력전압의 파형을 36-스텝으로 개선하였다. 이러한 방식의 인버터는 10Mvar$\~$30Mvar급 전후의 STATCOM에 적용하면 경제적이다. 2KVA급 STATCOM 시작품의 실험결과로부터 제안한 방식의 타당성을 입증하였다.

  • PDF