• Title/Summary/Keyword: 전산 열해석

Search Result 545, Processing Time 0.022 seconds

A Thermal Analysis of Liquid Rocket Combustors using a Modelling of Film Cooling Performance (막냉각 모형을 이용한 액체로켓엔진 연소기의 열해석)

  • Kim, Hong-Jip;Cho, Won-Kook;Moon, Yoon-Wan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 2006
  • A design program has been developed to predict film cooling performance of a liquid rocket engine. A thermal protecting effect of low mixture ratio gas layer has been analysed by CFD. A one-dimensional film cooling model based on the CFD results has been implemented to the previously developed design program of regenerative cooling. Satisfactory agreement has been achieved by comparing the predicted maximum heat flux at the throat of a subscale chamber and the average measured value, and the predicted nozzle average heat flux and the measured value for a full scale chamber with film cooling. It is ascertained that the film cooling is effective to reduce the throat heat flux in rocket engine chamber.

A Comparison between Various CFD Solvers for Analysis on Thermal Load in Smart Farm(Fluent, Open-FOAM, Blender) (스마트팜 열부하 분석을 위한 CFD 해석 도구 비교)

  • Lee, Jun-Yeob;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.170-170
    • /
    • 2017
  • 기후변화 따른 스마트팜 돈사 외부 환경의 변화에 대응하고, 사육 환경을 능동적으로 개선하기 위한 연구가 수행 중이다. 돈사 내 열전달 요소 간 상호 역학성 분석을 위해서 고려해야할 사항은 입기구, 보온 등, 열풍기, 단열제, 위치, 방향, 돈사의 연평균 온도, 습도, 연중 일사량, 가축의 열복사 등 상호 복잡하게 연관되어 있는 물리량이다. 돈사 전체 열손실, 자연발생 에너지량, 강제발생 에너지량, 난방용량 등을 고려한 순간 열부하 산정을 위한 여러 방법 중 우선적으로 CFD(Computational Fluid Dynamics)를 이용하였다. 순간 열부하 산정을 위한 해석 도구 선정에 있어서 다양한 유체 및 기체 전산 유체역학 Solver(Fluent, Open-FOAM, Blender)를 고려하였다. 공간 Mech를 수행하기 위한 도구로는 공개 소프트웨어 인 FreeFem++ 3.51-4 (http://www.freefem.org)를 이용하였다. 이 과정에서 일부 기체 (암모니아)의 농도를 난수로 변화시키는 기법을 적용하여 가상적으로 돈사의 환경을 Pseudo 시뮬레이션 하였다. 결과적으로 Fluent에 비하여 OpenFOAM을 이용하여 얻은 열유동의 방향(속도)과 크기 백터가 상대적으로 크게 나타났다. Fluent가 시계열 상에서 혼합 기체 물리량 변화를 무시할 수 있는 안정되고 균일한 환경에 적합하기 때문인 것으로 판단되었다. Blender의 경우 Lattice Boltzmann methods 과 Smoothed-particle hydrodynamics 방법을 이용한 유체/입자 동력학 모델링을 제공함에 있어 시각적 효과를 강조하는 기능에 중점을 두었다. Fluent와 Blender에서 제공하는 해석 연산 모듈의 정확성 검증을 위해선 공간 분해능을 높인 정밀 계측 시스템을 이용하여 검증할 필요가 있다. Open-FOAM를 이용한 열부하 분석 수행이 상대적으로 높은 절대값을 보이는 특성은 열부하 제어 시스템의 Overshoot를 유발할 가능성이 있으므로 이에 대한 해석 모델의 보정이 추가적으로 필요할 것이다. CFD의 한계인 시간 복잡도를 낮추고 상대적으로 높은 시계열 분해능을 확보할 경우 돈사 내 환기시스템에 맞는 소요 환기량 실시간 산정이 가능해지고 외부기상 및 돈사내부 복사열을 활용함과 동시에 돈군 순환에 상응하는 실시간 열부하 관리 시스템 도출이 가능할 것이다.

  • PDF

Heat efficiency Analysis of PVT module system using CFD (CFD를 이용한 PVT 모듈 열교환기 성능 해석)

  • Kim, Yangjoon;Kim, Dongkwon;Nam, Seungbaek;Cho, Insoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.112.2-112.2
    • /
    • 2011
  • PVT(Photovoltaic Thermal) 모듈은 태양광과 태양열 에너지를 동시 이용이 가능한 모듈로서 태양광전지(PV, Photovoltaic)모듈에 열교환기를 접합한 형태로 전기에너지뿐만 아니라 열에너지를 동시에 생산할 수 있는 시스템이다. 기존 PV 모듈은 일사량이 많으면 전력 생산량이 증가하는 동시에 PV모듈의 온도가 상승함에 따라 발전 효율이 감소하는 문제점이 있으며 일반적으로 $25^{\circ}C$이상 조건에서 모듈 온도가 $10^{\circ}C$ 증가할수록 발전효율의 약 4~5% 정도 감소하는 것으로 보고되고 있다. PVT 모듈은 기존 태양광모듈에 열교환기를 접합하여 냉각함으로써 PV모듈의 온도를 낮추어 발전효율을 증가시키는 동시에 부가적으로 발생하는 온수를 직접이용하거나 다양한 계통의 보조 열원으로 이용할 수 있는 장점이 있다. 본 연구에서는 수치해석기법(CFD)을 활용하여 PV모듈 냉각 및 온수 발생을 위한 열교환기를 설계하였으며 다양한 형상의 열교환기에 대해 유동해석을 수행하여 최적의 열흡수효율을 갖는 열교환기의 형상을 설계하였다. 또한 최적 설계된 PVT 모듈을 제작하여 실제 태양과 유사한 광원을 갖는 인공태양조건에서의 실내 실험을 통해 PVT 모듈의 성능을 검증하였으며 또한 실제 노상에 설치하여 ASHRAE 93-77의 실험기준과 ECN의 PVT 집열기 성능측정 가이드라인에 따라 옥외 시험평가를 하여 PVT 모듈의 성능 검증을 하였다. 최적 설계된 PVT모듈에 대한 성능평가 결과 기존 PV 모듈보다 발전효율이 약 15%(기존 발전효율 대비) 향상된 결과를 확인하였다.

  • PDF

Micromechanical Analysis for Effective Properties of HfC-coated Carbon/Carbon Composites (HfC-코팅 C/C 복합재료의 유효 물성 산출을 위한 미시역학 전산 해석)

  • Roh, Kyung Uk;Kim, Ho Seok;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.12
    • /
    • pp.961-968
    • /
    • 2020
  • In this study, the effective thermal conductivity and elastic modulus of heat-resistant coating materials are analyzed by using micromechanical computational models. Three-dimensional computational models for HfC-coated carbon/carbon composites were created with Simpleware, and finite element analysis was performed. The porosity and thickness changes in the coating layer were taken into account to identify the tendency of effective material properties. In addition, the coupon specimen was produced to compare the thermal conductivity measured by experiments with the one obtained by finite element analysis according to temperature changes, and the analysis results were close to the measured values. This confirms that micromechanical computational analysis is appropriate in the calculation of effective material properties of coating composites.

Thermo-Mechanical Analysis of Continuous-Adjustment Thruster using Explosion Pressure (폭압을 사용하는 연속조정 추진구조체의 열-구조해석)

  • Kim, Kyung-Sik;Kwon, Young-Doo;Kwon, Soon-Bum;Gil, Hyuck-Moon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.6
    • /
    • pp.699-705
    • /
    • 2011
  • High-maneuver missile is a projectile which demands a strong momentum at short time. To produce a necessary thrust for the flight, the gas of high temperature and pressure is generated through explosive combustion of solid propellant, and a great thrust can be obtained by expanding this high temperature and pressure gas. Although the operating time of a rocket motor is less than a few seconds, a failure of part or ablation near the throat of nozzle may take place during the expansion of high temperature and pressure gas for great thrust. In other words, for the precise control of a missile an exact stress analysis considering both, the thermal stress caused by the heat transfer between combustion gas and wall, and the mechanical stress caused by the pressure change in the flow, should be considered first. In this connection, this study investigated the safety, as a point of view of stress and melting point of the material, of the pre-designed thrust generating structure which is subjected to high temperature and pressure as a function of motor operating time.

Evaluation of Direct Vessel Injection Design With Pressurized Thermal Shock Analysis (가압 열충격해석에 의한 직접용기주입 설계의 평가)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.86-97
    • /
    • 1992
  • The purpose of this paper is to evaluate the direct vessel injection design from a pressurized thermal shock(PTS) viewpoint for the Combustion Engineering System 80+ A break of the main steam line from zero power and a 0.05 ft$^2$small break loss-of-coolant accident (LOCA) from full power were selected as the potential PTS events. In order to investigate the stratification effects in the reactor downcomer region, the fluid mixing analysis was performed using the COMMIX-IB code for steam line break and using the REMIX code for 0.05 ft$^2$small break LOCA. The stress distributions within the reactor vessel walls experiencing the pressure and the temperature transients were calculated using the OCA-P code for both events. The results of the analysis showed that a small break LOCA without decay heat presented the greatest challenge to the vessel, however, there is no crack initiation through end-of-life of the vessel with consideration of decay heat.

  • PDF

Heat Flow Characteristics on Type of Heat Transfer Plate for White Smoke Reduction under Uniform Flow Condition (균일유동에서 백연저감용 전열판 형태에 대한 열유동 특성)

  • Son, Jun;Cha, Jae Min;Wang, Zhen Huan;Kwon, Young Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.591-596
    • /
    • 2016
  • Numerical analyses were performed on the heat flow characteristics of a heat transfer plate with six different shapes (basic, rectangle, triangle, wave type) to reduce the level of white smoke at a stack. In this study, to examine the heat transfer performance (heat transfer capacity, pressure drop, turbulence kinetic energy, heat transfer coefficient) on the heat transfer plates, simulations were conducted using the commercial computational fluid dynamics software, ANSYS CFX Ver.14 under uniform flow conditions. The thermal flow phenomenon in a channel with six heat transfer plates could be predicted adequately under uniform flow conditions. The heat transfer capacity, pressure drop, turbulence kinetic energy, and heat transfer coefficient were affected by the flow rate, aspect ratio and plate shape. These results provide guidelines to design an effective heat exchanger with the wave type to reduce white smoke.

A Study on the Sloshing Impact Response Analysis for the Insulation System of Membrane Type LNG Cargo Containment System (LNG 탱크 방열구조의 슬로싱 충격 응답 해석법에 관한 연구)

  • Nho, In-Sik;Ki, Min-Seok;Lee, Jae-Man;Kim, Sung-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.531-538
    • /
    • 2011
  • To ensure the structural integrity of membrane type LNG tank, the rational assessment of impact pressure and structural responses due to sloshing should be preceded. The sloshing impact pressures acting on the insulation system of LNG tank are typical irregular loads and the structural responses caused by them also very complex behaviors including fluid structure interaction. So it is not easy to estimate them accurately and huge time consuming process would be necessary. In this research, a simplified method to analyze the dynamic structural responses of LNG tank insulation system under pressure time histories obtained by sloshing model test or numerical analysis was proposed. This technique basically based on the concept of linear combination of the triangular response functions which are obtained by the transient response analysis under the unit triangular impact pressure acting on structures in time domain. The validity of suggested method was verified through the example calculations and applied to the structural analysis of real Mark III type insulation system using the sloshing impact pressure time histories obtained by model test.

  • PDF

A Study on Numerical Simulation for Dynamic Analysis of Towed Low-Tension Cable with Nonuniform Characteristics (불균일 단면을 갖는 저장력 예인케이블의 동적해석을 위한 수치해석적 연구)

  • 정동호
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.1
    • /
    • pp.69-76
    • /
    • 2003
  • Low-tension cables have been increasingly used in recent years due to deep-sea developments and the advent of synthetic cables. In the case of low-tension cables, large displacements may happen due to relatively small restoring forces of tension and thus the effects of fluid and geometric non-linearities and bending stiffness. A Fortran program is developed by employing a finite difference method. In the algorithm, an implicit time integration and Newton-Raphson iteration are adopted. For the calculation of huge size of matrices, block tri-diagonal matrix method is applied, which is much faster than the well-known Gauss-Jordan method in two point boundary value problems. Some case studies are carried out and the results of numerical simulations are compared with a in-house program of WHOI Cable with good agreements.

Fire Loading Analysis of Underground Box Structure with Considering of Concrete Spalling I : Spalling Analysis (박리를 고려한 지하박스구조물의 화재하중해석 I : 박리해석)

  • Lee, Gye-Hee;Choi, Ik-Chang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.477-483
    • /
    • 2007
  • In this study, the numerical fire analysis for temperature distribution and spalling behavior of underground concrete box structures that contained lifelines, such as power cables and communication cables. The temperature field of inner space was assumed based on the fire curve with the thermal gradient obtained from CFD analysis. It was assumed that the spalling behaviors of concrete are occurred when the concrete temperature reached the threshold, as dehydration degree. In this case, the elements correspond to spalling parts were removed and the analysis model were updated. Three fire scenarios were analyzed and the results were showed adequate spalling behavior. The bearing capacities of the box structures would be estimated in the companion paper.