• Title/Summary/Keyword: 전산화 단층 촬영

Search Result 1,090, Processing Time 0.029 seconds

Use of Coronary CT Angiography as a Screening Tool for Coronary Artery Disease in Asymptomatic Healthy Individuals or Patients (무증상 정상인 또는 환자의 관상동맥 질환 선별 검사로서 관상동맥 전산화단층촬영 혈관조영술의 유용성)

  • Gong Yong Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.54-69
    • /
    • 2022
  • Early detection of potential asymptomatic coronary artery disease is very important, as patients with sudden cardiac death often do not show symptoms such as chest pain or motor dyspnea. Coronary CT angiography (CCTA) has long been unjustified as a screening tool for asymptomatic patients because of the risks posed by radiation exposure. However, there are still various opinions regarding the usefulness of CCTA for screening for coronary artery disease (CAD) in asymptomatic healthy individuals or patients. This review investigated the usefulness of coronary artery calcium score and CCTA as screening tests for CAD in asymptomatic healthy individuals or patients through various literature reviews. With the development of CT technology, recent studies have been conducted in asymptomatic CAD patients with a reduced radiation dose of less than 1 mSv. A total of 2.6% of asymptomatic subjects on CCTA found significant CAD over 70%, and it was concluded that screening CCTA for CAD showed prognostic power in predicting the future occurrence of CAD in asymptomatic people. However, after the completion of the current NIH SCOT-HEART 2 study, it may be possible to determine whether CCTA is appropriate as a screening tool for CAD in asymptomatic healthy individuals.

Image Quality Evaluation in Computed Tomography Using Super-resolution Convolutional Neural Network (Super-resolution Convolutional Neural Network를 이용한 전산화단층상의 화질 평가)

  • Nam, Kibok;Cho, Jeonghyo;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Lee, Dahye
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.211-220
    • /
    • 2020
  • High-quality computed tomography (CT) images enable precise lesion detection and accurate diagnosis. A lot of studies have been performed to improve CT image quality while reducing radiation dose. Recently, deep learning-based techniques for improving CT image quality have been developed and show superior performance compared to conventional techniques. In this study, a super-resolution convolutional neural network (SRCNN) model was used to improve the spatial resolution of CT images, and image quality according to the hyperparameters, which determine the performance of the SRCNN model, was evaluated in order to verify the effect of hyperparameters on the SRCNN model. Profile, structural similarity (SSIM), peak signal-to-noise ratio (PSNR), and full-width at half-maximum (FWHM) were measured to evaluate the performance of the SRCNN model. The results showed that the performance of the SRCNN model was improved with an increase of the numbers of epochs and training sets, and the learning rate needed to be optimized for obtaining acceptable image quality. Therefore, the SRCNN model with optimal hyperparameters is able to improve CT image quality.

Density Profile Measurement of Needle-punched Carbon/Carbon Nozzle Throat by the Analysis of Computed Tomography Image (전산화 단층촬영 영상 분석에 의한 탄소/탄소 목삽입재의 밀도 분포 측정)

  • Kim Dong-Ryun;Yun Nam-Gyun;Lee Jin-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.469-474
    • /
    • 2005
  • Tn this study, the noll-destructive computed X-ray tomography was adopted to observe the density distribution of the needle-punched C-C composites nozzle throat. The density distribution of the C-C was evaluated within ${\pm}0.01g/cm^3$ with 98.74% confidence when the correction of the image and high signal-to-noise ratio were achieved by the optimization of the beam hardening, the electrical noise and the scattered X-ray. The density variation of the C/C with the computed tomography was in good agreement with the results obtained by the water immersion method and the observation with scanning electron microscope.

  • PDF

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

Evaluation of Usefulness in New Immobilization Device with 3D CT Angiography for Lower Extremity (전산화단층촬영검사에서 하지의 3D 혈관조영검사를 위한 새로운 고정기구의 유용성 평가)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.184-191
    • /
    • 2007
  • Our objective was to develop and evaluate a non-invasive device for rigid immobilization and surface disease non-contact of the table in the lower extremity during CT angiography. The immobilization device consists of two components. The patient's lower limb device stabilizing elements made of polyethylene resin soft materials, and pelvis parts foam pad is used for non-contact surface. In a Prospective study the lower extremity device was used in patients who underwent a CT angiography of the lower limb. Immobilization with our device was well tolerated by all patients. The quality of the resulting images in the popliteal and infrapopliteal region was rated by five-point scale. The rigid immobilization resulted in a complete absence of motion artifacts. The new device is an effective, well tolerated and easily used immobilization that is suitable of use in 3D lower extremity CT angiography.

Analysis of the O-Ring Deformation Behavior by the Computed Tomography (전산화 단층촬영에 의한 오링 변형 거동 분석)

  • Kim, Dong-Ryun;Kim, Jae-Hoon;Park, Sung-Han;Lee, Hwan-Gyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The object of this study is to develop the examination technique for measuring the O-ring deformation behavior under the pressure and the squeezed condition simultaneously. The O-ring deformation measuring device in which two grooves were dug to insert the two O-rings was manufactured to be not deformed under the high pressure and the 1 mm and 0.1 mm gap were designed to measure the extrusion lengths under the internal pressure. The beam hardening correction, the histogram analysis and the dead zone correction were executed to exactly measure the shape of O-ring deformation and the lengths of the O-ring deformation were measured by the LSF and the ERF. The computed tomography applied the pressure of 0, 1.378, 4.902, 9.804, 15.692 MPa at 22.3% squeezed condition and the expanded diameter, contact length and extrusion depth were measured in each pressure. The shape of O-ring deformation was evaluated by the FEM to verify the results of measuring by the computed tomography and the area of O-ring was mutually compared to the area measured by the computed tomography.

Beyond Coronary CT Angiography: CT Fractional Flow Reserve and Perfusion (전산화단층촬영 관상동맥조영술: 분획혈류예비력과 심근관류 영상)

  • Moon Young Kim;Dong Hyun Yang;Ki Seok Choo;Whal Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.3-27
    • /
    • 2022
  • Cardiac CT has been proven to provide diagnostic and prognostic evaluation of coronary artery disease for cardiovascular risk stratification and treatment decision-making based on rapid technological development and various research evidence. Coronary CT angiography has emerged as a gateway test for coronary artery disease that can reduce invasive angiography due to its high negative predictive value, but the diagnostic specificity is relatively low. However, coronary CT angiography is likely to overcome its limitations through functional evaluation to identify the hemodynamic significance of coronary artery disease by analyzing myocardial perfusion and fractional flow reserve through cardiac CT. Recently, studies have been actively conducted to incorporate artificial intelligence to make this more objective and reproducible. In this review, functional imaging techniques of cardiac computerized tomography are explored.

Basaloid Squamous Cell Carcinoma of the Lung: Two Case Reports with CT Imaging Findings (폐의 기저세포양 편평세포암: 두 개의 증례 보고와 전산화단층촬영 영상소견)

  • Joo Hee Kim;Hyun Jung Yoon;Eunju Lee;Eun Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.746-752
    • /
    • 2020
  • Basaloid squamous cell carcinoma of the lung is now considered a subtype of squamous cell carcinoma as per the 2015 WHO classification and remains a relatively unknown type of lung cancer due to its rarity. Here we report two cases of basaloid squamous cell carcinoma of the lung and their CT findings to clarify some of the radiologic features of this type of cancer. Two patients aged 85 and 68 years with lung basaloid squamous cell carcinoma visited our institution and underwent surgical resection. On CT, the lesions were 3.1 and 2.8 cm in size, respectively, well-defined, round in shape with lobulated margins and prominent intratumoral necrosis. The latter case was followed after operation for 20 months, and there was no recurrence of the disease on CT. Although very rare, basaloid squamous cell carcinoma should be considered a subtype of lung cancer in tumors sharing these CT findings.

The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism (폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성)

  • Kim, Woo-Gyu;Lim, Byung-Sung;Kim, Mi-Young;Hwang, Hweung-Kon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.669-680
    • /
    • 1999
  • Background: Pulmonary thromboembolism(PTE) is a life threatening disease that needs early diagnosis. Spiral CT angiography depict thromboemboli in the central pulmonary vessels with greater than 90% sensitivity and specificity, which approaches the results of pulmonary angiography in the Prospective Investigation of Pulmonary Embolism Diagnosis(PIOPED) study. This study was performed to evaluate the findings and the diagnostic value(clinical utility) of the spiral CT angiography with 2D image(multiplanar reformation) and 3D images(Shaded surface display, Minimal intensity projection) in the pulmonary thromboembolism. Methods: We retrospectively analysed spiral CT angiography and pulmonary angiography, lung scan and clinical recordings of 20 patients who had PTE diagnosed by spiral CT angiography(n=19 cases) or pulmonary angiography(n=l case) from September 1997 to August 1998. Among 20 patients who had underwent spiral CT angiography, 14 patients could be performed lung perfusion scan at the same time. We analyzed the vascular and parenchymal change in spiral CT angiogram. Results: Anatomical distribution of PTE was as follows: 1) left lung(n= 103)

  • PDF

The Diagnostic Utility of PET-CT for the Preoperative Evaluation of Lymph Node Metastasis in Gastric Cancer Patients (위암 환자의 수술 전 림프절 전이 평가를 위한 PET-CT의 진단적 유용성)

  • Park, Sung-Hyuk;Cho, Min-Su;Ryu, Hoon;Bae, Keum-Seok;Kim, Ik-Yong;Kim, Dae-Sung
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.250-255
    • /
    • 2008
  • Purpose: The purpose of this study was to assess the diagnostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for detecting the lymph node (LN) metastasis of gastric cancer. Materials and Methods: 119 patients (M : F=89 : 30; mean age: 64) with gastric cancer were referred for preoperative FDG-PET/CT scanning and spiral enhanced abdominal pelvic CT from June 2006 to July 2008, and these were the subjects of our study. All the patients underwent curative radical gastrectomy and lymph node dissection. A final diagnosis was made for all the patients by the histology of the surgical specimens. Results: Both PET/CT and enhanced CT showed similar sensitivity for detecting regional lymph node metastasis (32.6% vs 39.5%, respectively). PET/CT was more accurate than enhanced CT for detecting regional lymph node metastasis (67.2% vs 63.0%, respectively), and PET/CT showed better specificity (86.8% vs 76.3, respectively) and a better positive predictive value (PPV) (58.3% vs 48.6%, respectively). PET/CT showed better specificity (98.0% vs 88.2%, respectively) and accuracy (79.4% vs 73.9%, respectively) than enhanced CT for detecting early gastric cancer. PET/CT showed better specificity (64.0% vs 52.0%, respectively), a better PPV (60.9% vs 57.1%), a better negative predictive value (NPV) (48.5% vs 46.4%, respectively) and better accuracy (53.6% vs 51.8%, respectively) than enhanced CT for detecting advanced gastric cancer. Conclusion: FDG-PET/CT is more usefulness than enhanced CT for making the preoperative diagnosis of regional LN metastases from gastric cancers.

  • PDF