충돌분무와 액막의 열전달 해석모델을 고려한 범용 열/유체 프로그램 NUFLEX의 개발 (DEVELOPMENT OF A GENERAL PURPOSE THERMO/FLUID FLOW ANALYSIS PROGRAM NUFLEX WITH WALL IMPINGEMENT AND HEAT TRANSFER ANALYSIS MODEL OF LIQUID FILM)

  • 김현정;노경철;유홍선;허남건
    • 한국전산유체공학회지
    • /
    • 제13권2호
    • /
    • pp.68-72
    • /
    • 2008
  • NUFLEX is a general purpose thermo/fluid flow analysis program which has various physical models including spray. In NUFLEX, spray models are composed of breakup and collision models of droplet. However, in case of diesel engine, interaction between wall-film and impingement model considering heat transfer is not coded in NUFLEX. In this study, Lee & Ryou impingement & wall-film model considering heat transfer is applied to NUFLEX. For the verification of this NUFLEX program, numerical results are compared with experimental data. Differences of film thickness and radius between numerical results and experimental data are within 10% error range. The results show that NUFLEX can be used for comprehensive analysis of spray phenomena.

범용 열/유체 유동해석 프로그램 NUFLEX의 개발 (A Development of General Purpose Program NUFLEX for the Analysis of Heat/Fluid Flow)

  • 허남건;원찬식;손기헌;유홍선;신동신
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 추계 학술대회논문집
    • /
    • pp.53-59
    • /
    • 2004
  • A general purpose program NUFLEX for the analysis of 3-D heat/fluid flow in complex geometry with pre/post processor have been developed, which consists of a flow solver based on FVM and a dedicated pre/post processor. The program employs a general non-orthogonal grid system and solve laminar and turbulent (lows with standard and RNG $\kappa-\epsilon$ turbulence models. NUFLEX is capable of analysing two-phase flow with topologically complex interface, turbulent diffusion combustion, solidification problems and magnetic flow. For the purpose of verification of the program and testing the applicability, several practical problems are solved and compared with the available data. Comparison of the NUFLEX results with that by the STAR-CD program has been also made for the same flow configuration and grid structure.

  • PDF

충돌분무 액막의 열전달 해석모델을 고려한 범용 열/유체 프로그램 NUFLEX의 개발 (Development of a general purpose thermo/fluid flow analysis program NUFLEX with heat transfer analy sis model of impinging liquid film)

  • 김현정;노경철;유홍선;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.71-74
    • /
    • 2008
  • NUFLEX is a general purpose thermo/fluid flow analysis program which has various physical models including spray. In NUFLEX, spray models are composed of breakup and collision models of droplet. However, in case of diesel engine, interaction between wall-film and impingement model considering heat transfer is not coded in NUFLEX. In this study, Lee & Ryou impingement & wall-film model considering heat transfer is applied to NUFLEX. For the verification of this NUFLEX program, numerical results are compared with experimental data. Differences of film thickness and radius between numerical results and experimental data are within 10% error range. The results show that NUFLEX can be used for comprehensive analysis of spray phenomena.

  • PDF

전산유체역학을 이용한 스프링클러헤드의 형상 개선 (An improvement of sprinkler head design using computational fluid dynamics)

  • 박단아
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제4회(2015년)
    • /
    • pp.606-611
    • /
    • 2015
  • 초기 화재 진압을 위해 사용되는 스프링클러(sprinkler) 설비는 스프링클러헤드의 형태에 따라 살수 분포가 달라진다. 화점의 발생 위치는 특정하기 어려우므로 스프링클러의 살수범위(spray coverage)가 넓게 퍼지는 형태가 되는 것이 확률적으로 가장 큰 효율성을 가진다. 본 연구에서는 EDISON_전산열유체 시스템의 다상유동 해석자를 활용하여 스프링클러헤드의 형태에 따라 살수각과 국부 유동장을 분석하였다. 3차원 형상을 가지는 스프링클러헤드 형상을 2차원 단면으로 나누어 해석하였으며 프레임(frame)과 반사판(deflector)의 형상에 따른 유동장의 변화를 살펴보았고 살수각(spray angle)을 정량적으로 나타내었다. 최종적으로 최대 최소의 살수각을 갖는 2차원 스프링클러헤드를 형상화하였고 이를 중첩하여 살수 범위를 넓게 갖는 스프링클러헤드를 3차원 모델링하였다.

  • PDF

외장형 HEAT PIPE 가 장착된 정지궤도 위성 패널의 열해석 (THERMAL ANALYSIS OF SURFACE HEAT PIPE INSTALLED PANEL OF GEOSTATIONARY SATELLITE)

  • 전형열;김정훈
    • 한국전산유체공학회지
    • /
    • 제11권3호
    • /
    • pp.8-13
    • /
    • 2006
  • The north panel of a geostationary satellite is used as one of the main radiators, on which communication equipment or bus equipment are installed. The thermal control of panel is designed by using embedded heat pipes and surface heat pipes (or external heat pipes) to spread out heat dissipated from equipment all over the radiator evenly and finally to reject the heat to the space through the radiator efficiently. This panel is also divided by several areas based on the operating temperature and dissipation of equipment in order to increase heat rejection capability of radiator. The thermal analysis is carried out for the hot case, Winter Solsitce EOL (End Of Life), in order to validate thermal design of the panel utilized 6 surface heat pipes and 8 embedded heat pipes. The sensitivity studies for the heat pipe failure case and no heat pipe case are performed and compared to its normal state. The heat transport capability of heat pipe is also obtained from these calculations.

열해석 모델 간략화 및 동적특성에 관한 연구 (A STUDY ON THERMAL MODEL REDUCTION AND DYNAMIC RESPONSE)

  • 전형열;김정훈
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.37-44
    • /
    • 2014
  • A detailed satellite panel thermal model composed of more than thousands nodes can not be directly integrated into a spacecraft thermal model due to its node size and the limitation of commercial satellite thermal analysis programs. For the integration of the panel into the satellite thermal model, a reduced thermal model having proper accuracy is required. A thermal model reduction method was developed and validated by using a geostationary satellite panel. The temperature differences of main components between the detailed and the reduced thermal model were less than $1^{\circ}C$ in steady state analysis. Also, the dynamic responses of the detailed and the reduced thermal model show very similar trends. Thus, the developed reduction method can be applicable to actual satellite thermal design and analysis with resonable accuracy and convenience.

미세중력장 CdTe 흘로우팅존 생성에서 결정체-용융액 계면주위의 열응력 (Thermal Stresses Near the Crystal-Melt Interface During the Floating-Zone Growth of CdTe Under Microgravity Environment)

  • 이규정
    • 한국전산유체공학회지
    • /
    • 제3권1호
    • /
    • pp.100-107
    • /
    • 1998
  • A numerical analysis of thermal stress over temperature variations near the crystal-melt interface is carried out for a floating-zone growth of Cadmium Telluride (CdTe). Thermocapillary convection determines crystal-melt interfacial shape and signature of temperature in the crystal. Large temperature gradients near the crystal-melt interface yield excessive thermal stresses in a crystal, which affect the dislocations of the crystal. Based on the assumption that the crystal is elastic and isotropic, thermal stresses in a crystal are computed and the effects of operating conditions are investigated. The results show that the extreme thermal stresses are concentrated near the interface of a crystal and the radial and the tangential stresses are the dominant ones. Concentrated heating profile increases the stresses within the crystal, otherwise, the pulling rate decreases the stresses.

  • PDF

인공위성 패널 열해석모델 간소화 알고리즘 연구 (A STUDY ON THERMAL MODEL REDUCTION ALGORITHM FOR SATELLITE PANEL)

  • 김정훈;전형열;김승조
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.9-15
    • /
    • 2012
  • Thermal model reduction algorithms and techniques are introduced to condense a huge satellite panel thermal model into the simplified model on the purpose of calculating the thermal responses of a satellite on orbit. Guyan condensation algorithm with the substitution matrix manipulation is developed and the mathematical procedure is depicted step by step. A block-form LU decomposition method is also invited to compare the developed algorithm. The constructed reduced thermal model induced from the detailed model based on a real satellite panel is satisfying the correlation criterion of ${\pm}2^{\circ}C$ for the validity accuracy. Guyan condensation algorithm is superior to the block-form LU decomposition method on computation time.

입구 압력에 따른 열진공 시험용 베이스플레이트의 열유동 특성에 관한 수치해석적 연구

  • 고태식;서희준;조혁진;박성욱;임성진;문귀원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.140.2-140.2
    • /
    • 2014
  • 인공위성은 우주공간의 고진공 상태와 태양 복사열에 의한 고온 및 극저온이 반복되는 가혹한 환경으로 인해 주요 부품의 기능장애가 초래되므로 발사전 지상에서 열진공 시험장비를 이용한 열진공시험을 수행한다. 위성체의 열진공 시험에 사용되는 열교환기인 베이스플레이트(Baseplate)는 우주 열환경을 모사하기 위하여 직접 방열판 표면에 고온 및 저온의 유체를 공급하여 시험 요구에 따른 필요한 열을 공급하게 된다. 일반적으로 우수한 성능의 위성체 부품의 검증을 위해서 지상의 열환경 시험은 접촉식 히터 및 열교환기를 사용하게 되는데, 이때 적절한 히터 및 블로워 파워를 선정하고 챔버 슈라우드와 열교환에 있어 간섭이 없도록 장비를 운용해야 한다. 본 연구에서는 상용프로그램을 이용하여 열진공 시험용 베이스플레이트에 대하여 전산해석을 수행하였으며, 이를 통해 베이스플레이트 내의 작동 유체의 입구 압력에 의한 열진공 시험용 열교환기의 성능 특성을 관찰하였다.