• Title/Summary/Keyword: 전리함

Search Result 468, Processing Time 0.026 seconds

Determination of Quality Correction Factors for a Plane-Parallel Chamber in High Energy Electron Beams using Monte Carlo Calculation (몬테칼로 계산을 이용한 평판형 전리함의 고에너지 전자선에 대한 선질보정인자 결정)

  • Jeong, Dong-Hyeok;Lee, Jeong-Ok
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.89-95
    • /
    • 2008
  • The quality correction factor for used beam and qualities is strongly required for clinical dosimetry by TRS-398 protocol of IAEA. In this study the quality correction factors for a commercial plane-parallel ionization chamber in high energy electron beams were calculated by Monte Carlo code(DOSRZnrc/EGSnrc). In comparison of quality correction factor, the difference between this study and TRS-398 were within 1% in 5-20 MeV. In case of 4MeV the difference was 1.9%. As an independent method of determination of quality correction factor this study can be applied to evaluate values in the protocol or calculate the factor for a new chamber.

  • PDF

Direct Calculation of TRS-398 Quality Correction Factors for High Energy Photons (고에너지 광자선에 대한 TRS-398 선질보정인자의 직접 계산)

  • Shin Kyo-Chul;Oh Young-Kee;Kim Jeung-Kee;Kim Jhin-Kee;Kim Ki-Hwan;Jeong Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.54-60
    • /
    • 2006
  • In order to apply the TRS-398 dosimetry protocol developed by IAEA we directly calculated the quality correction factors for high energy photons. The calculations were peformed for seven commercial cylindrical chambers (A12, IC70, N23333, N30001, N30006, NE2571, PR06C/G). In comparison with quality correction factors given by TRS-398 our results were in good agreement within ${\pm}0.3%$ (maximum ${\pm}0.3%$) for all chambers and photon qualities.

  • PDF

Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays (측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰)

  • Lee Yong Ha;Park Kyung Ran;Lee Jong Young;Lee Ik Jae;Park Young Woo;Lee Kang Kyoo
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.322-329
    • /
    • 2003
  • Purpose: It is difficult to exactly determine the surface dose and the dose distribution In buildup region of high energy X-rays by using the conventional ion chamber. The aim of this study Is to evaluate the accuracy of widely used dosimetry systems to measure the surface dose and the depth of maximum dose (d$_{max}$). Materials and Methods: We measured the percent depth dose (PDD) from the surface to the d$_{max}$ in either a water phantom or in a solid water phantom using TLD-100 chips, thimble type ion chamber, diode detector, diamond detector and Markus parallel plate ion chamber for 6 MV and 15 MV X-rays, 10$\times$10 cm$^{2}$, at SSD=100cm. We analysed the surface dose and the d$_{max}$. In order to verify the accuracy of the TLD data, we executed the Monte Carlo simulation for 5 MV X-ray beams. Results: The surface doses In 6 MV and IS MV X-rays were 29.31% and 23.36% ior Markus parallel plate ion chamber, 37.17$\%$ and 24.01$\%$ for TLD, 34.87$\%$ and 24.06$\%$ for diamond detector, 38.13$\%$ and 27.8$\%$ for diode detector, and 47.92$\%$ and 35.01$\%$ for thimble type ion chamber, respectively. in Monte Carlo simulation for 6 MV X-rays, the surface dose was 36.22$\%$, which Is similar to the 37.17$\%$ of the TLD measurement data. The d$_{max}$ In 6 WV and 15 MV X-rays was 14$\~$16 mm and 27$\~$29 mm, respectively. There was no significant difference in the d$_{max}$ among the detectors. Conclusion: There was a remarkable difference in the surface dose among the detectors. The Markus parallel plate chamber showed the most accurate result. The surface dose of the thimble ion chamber was 10$\%$ higher than that of other detectors. We suggest that the correction should be made when the surface dose of the thimble ion chamber Is used for the treatment planning ion the supeficial tumors. All the detectors used In our study showed no difference in the d$_{max}$.

Determining Ion Collection Efficiency in a Liquid Ionization Chamber in Co-60 Beam (Co-60 빔에서 액체 전리함의 이온 수집 효율 결정 연구)

  • Choi, Sang Hyoun;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • Liquid ionization chamber is filled with liquid equivalent material unlike air filled ionization chamber. The high density material allow very small-volume chamber to be constructed that still have a sufficiently high sensitivity. However liquid ionization chamber should be considered for both initial recombination and general recombination. We, therefore, studied using the Co-60 beam as the continuous beam and the microLion chamber (PTW) for comparing the ion collection efficiency by Greening theory, two-dose rate method and our experiment method. The measurements were carried out using Theratron 780 as the cobalt machine and water phantom and 0.6 cc Farmer type ionization chamber was used with microLion chamber in same condition for measuring the charge of microLion chamber according to the dose rates. Dose rate was in 0.125~0.746 Gy/min and voltages applied to the microLion chamber were +400, +600 and +800 V. As the result, the collection efficiency by three method was generally less than 1%. In particular, our experimental collection efficiency was in good agreement within 0.3% with Greening theory except the lowest two dose rates. The collection efficiency by two-dose rate method also agreed with Greening theory generally less than 1%, but the difference was about 4% when the difference of two dose rates were lower. The ion recombination correction factors by Greening theory, two-dose rate method and our experiment were 1.0233, 1.0239 and 1.0316, respectively, in SSD 80 cm, depth 5 cm recommended by TRS-398 protocol. Therefore we confirmed that the loss by ion recombination was about 3% in this condition. We think that our experiment method for ion recombination correction will be useful tool for radiation dosimetry in continuous beam.

A study on silicon wafer surfaces treated with electrolyzed water (전리수에 의한 Si 웨이퍼 표면 변화 연구)

  • 김우혁;류근걸
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.218-221
    • /
    • 2002
  • 80년대 반도체 산업의 급격한 성장으로 오늘날 반도체 산업은 반도체소자의 초고집적화, 웨이퍼의 대구경화로 발전이 거듭났으며, 소자의 성능과 생산 수율의 향상을 위하여 실리콘 웨이퍼의 세정하는 기술 및 연구를 계속 진행하고 있다. 기존의 반도체 세정은 과다한 화학약품의 사용으로 비 환경친화적이며, 이에 본 연구에서는 기존의 세정방법을 대체하기 위한 방법으로 환경친화적인 전리수를 이용한 반도체 세정법을 하였다. 이때 실리콘 웨이퍼 표면의 원자적 상태의 변화가 발생하여 다양한 방법으로 확인할 수 있다. 본 연구에서는 이러한 분석을 하기 위하여 기존세정의 화학약품과 전리수로 세정한 웨이퍼의 표면을 비교하였으며, 또한 온도 및 시간별 표면상태변화를 분석하였다. 특히 접촉각 변화에 중점을 두어 변화를 관찰하였으며, 음극수의 경우 17.28。, 양극수의 경우 34.l。의 낮은 접촉각을 얻을 수 있었다.

Saturation Characteristics of a Boron-lined ionization Chamber

  • Chae, Sung-Ki
    • Nuclear Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.94-102
    • /
    • 1973
  • Saturation characteristics of a current-type ionization chamber are investigated theoretically and experimentally in the columnar recombination region. The experiments were performed using a boron-lined cylindrical ionization chamber filled with nitrogen or helium at pressures of 760 mmHg and 380 mmHg. The collection efficiency deduced from the analytical method is in good agreement with the experimental results. This theory makes it possible to predict saturation characteristics for all ionization intensities with only the design data.

  • PDF

Detection and Measurement of Non-ionizing Radiations (비전리방사선의 검출 및 측정)

  • Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.3
    • /
    • pp.155-162
    • /
    • 1995
  • The state-of-the art of detection and measurements of non-ionizing radiations are reviewed in relation to protection requirements, especially for electromagnetic and ultraviolet radiations. Dosimetric quantities, instruments and considerations needed for measurement are briefly explained. For electromagnetic radiation, the power density levels from various practical sources are summarized for reference uses. Large errors remain in the measurements of non-ionizinf radiations in general. Technical needs of development in measurement and dosimetry of non-ionizing radiations, therefore, are promissing when the increasing public concerns about the adverse health effects of non-ionizing radiations and proliferation of their uses are taken into account.

  • PDF

Small Field Dosimetry for Stereotacitc Radiosurgery (뇌정위적 방사전수술을 위한 소조사면 측정)

  • 최동락;안용찬;이정일;허승재
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.59-64
    • /
    • 1995
  • The aim of presentation is to obtain the beam parameters for tratment planning of steretactic radiosurgery. The dosimerical parameters such as TMR, scatter factor, and OAR was measured using diode, film, micro ion chamber, and thimble chanber for water phantom scanning. The results were compared each other. As a result, we determined OAR from film and scatter factor and TMR from diode as a basic data for treatment planning.

  • PDF

Technical Treatment of Oceanic Living-things in Ship's Ballast-water by Hydroxyl Radical of Electrical Plasma (강 전리 플라즈마 수산기에 의한 선박안정수 해양외래생물의 처리 방안)

  • 소대화;장지도;선우택
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.356-359
    • /
    • 2003
  • 선박이 배출하는 안정수(ballast water)는 외부로부터 유해 생물들이 유입되어 전파해 오는 주요경로로써, 해양환경 변화를 초래하는 매우 중요하고 위험한 일중의 하나이다. 그러나 이에 대한 효과적인 처리방법은 아직까지도 미흡한 상태이다. 선박 안정수에 포함되어 타 지역으로부터 옮겨지는 외래침입생물 처리 방안의 하나로, 강 전리방전 기술을 적용하여 고 밀집 산소와 물분자로부터 고농도 수산자유기(OH: hydroxyl radical)를 전리, 발생시켜서 활성입자를 신속히 확산시켜 비교적 낮은 수산기농도 하에서 유해성침입생물을 소멸 처리하는 환경 친화적 녹색 청정처리방법을 제안하였다. 제안된 기술은 대상물의 처리 후 부수적으로 발생할 수 있는 처리잔류물이 전혀 발생하지 않으며, 인공적 화학성분의 약제를 사용하지 않는 저렴한 처리방법이므로 대ㆍ소형 원양선박의 안정수에 들어있는 외래침입생물의 타 지역 해양확산을 안전하게 처리할 수 있는 자연치유적 신기술이다.

  • PDF

Killing effect of anodic eletrolyzed water on Propionibacterium acnes (양극전리수의 여드름균(Propionibacterium acnes)에 대한 살균효과)

  • Park Seul-Ki;Ryoo Kun-Kul;Lee Yoon-Bae;Lee Jong-Kwon;Lee Mi-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.295-296
    • /
    • 2005
  • 본 연구에서는 양극전리수의 여드름균에 대한 제어력을 조사해보았다.. 그 결과 대조군과 비교해보았을 때 여드름균은 양극전리수에 1 분 동안 노출되었을 때 완전히 사멸되었다.

  • PDF