• Title/Summary/Keyword: 전류감지

Search Result 271, Processing Time 0.034 seconds

5-TFT OLED Pixel Circuit Compensating Threshold Voltage Variation of p-channel Poly-Si TFTs (p-채널 다결정 실리콘 박막 트랜지스터의 문턱전압 변동을 보상할 수 있는 5-TFT OLED 화소회로)

  • Chung, Hoon-Ju
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.3
    • /
    • pp.279-284
    • /
    • 2014
  • This paper proposes a novel OLED pixel circuit to compensate the threshold voltage variation of p-channel low temperature polycrystalline silicon thin-film transistors (LTPS TFTs). The proposed 5-TFT OLED pixel circuit consists of 4 switching TFTs, 1 OLED driving TFT and 1 capacitor. One frame of the proposed pixel circuit is divided into initialization period, threshold voltage sensing and data programming period, data holding period and emission period. SmartSpice simulation results show that the maximum error rate of OLED current is -4.06% when the threshold voltage of driving TFT varies by ${\pm}0.25V$ and that of OLED current is 9.74% when the threshold voltage of driving TFT varies by ${\pm}0.50V$. Thus, the proposed 5T1C pixel circuit can realize uniform OLED current with high immunity to the threshold voltage variation of p-channel poly-Si TFT.

Risk Factors of Electrical Fire at the Panelboard and Investigation of Field Conditions (분전반에서의 전기화재 위험요소 및 현장실태조사 분석)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Lee, Ki-Yeon;Choi, Yong-Sung;Choi, Chung-Seog;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2206-2207
    • /
    • 2008
  • 본 논문에서는 분전반에서의 화재 위험 요소와 화재위험 요소에 대한 현장 실태조사 결과를 분석하였다. 분전반에서의 화재 위험 요소는 크게 전기적 요인, 환경적 요인, 물리적 요인으로 나눌 수 있으며 전기적 요인으로는 단락, 과부하(과전류), 접촉불량, 전류 불평형 등이 있으며 환경적 요인으로는 수분(염분 등), 먼지(분진, 목분, 철분 등), 온도(고온) 등에 의한 절연파괴, 기기 손상, 오동작 등이 있다. 물리적 요인으로는 기계적인 진동이나 충격 등에 의한 전기적 접속부의 이완에 의한 발열 등을 들 수 있다. 이러한 화재 위험 요인에 대하여 현장실태조사를 실시한 결과, 일부 분전반에서 내부에 먼지 등 이물질이 차단기, 전선, 단자대 등의 표면에 부착되어 있음을 확인할 수 있었으며 수분이나 염분 등의 영향으로 전극간 절연물 표면의 열화로 화재가 발생할 가능성이 있다. 또한, 적외선 열화상 분석결과, 일부 차단기 단자에서 국부 발열이 관측되었으며, 부하 분담의 불평형에 의한 발열도 확인되었다. 이러한 위험요인에 의한 화재 예방을 위하여 규정된 전선 굵기의 사용과 적정 체결압력의 확보, 상간 전류 불평형을 줄이기 위한 부하 분담의 조정이 필요하다. 향후, 분전반에서의 전기화재, 감전사고 등 전기재해의 예방을 위하여 지속적이고 체계적인 유지관리는 물론 사고 발생 전에 이상 징후를 사전에 감지하여 조치를 취할 수 있도록 하는 기술의 개발과 현장 적용이 요구된다.

  • PDF

The Development of a Precision BLDC Servo Position Controller for the Composite Smoke Bomb Rotational Driving System (복합연막탄 선회구동장치를 위한 정밀 BLDC 서보 위치 제어기 개발)

  • Koo, Bon-Min;Park, Moo-Yurl;Choi, Jung-Keyung;Choi, Sung-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.951-954
    • /
    • 2005
  • This paper presents a study on the accuracy position Controller design for the Composite Smoke Bomb Rotational driving system using a BLDC servo motor. Function of Smoke Bomb is blind in the enermy's sight so that need to high response. The BLDC servo motor controller was designed with DSP(TMS320VC33), IGBT(Insulated Gate Bipolar. Transistor), IGBT gate driver and CPLD(EPM7128). This paper implements those control with vector control and MIN-MAX PWM. Vector control requires information about rotor positions, a resolver should be used to achieve that. The main controller is implemented with a TMS320VC33 high performance floating-point DSP(Digital Signal Process) and PWM Generator is embodied using EPM7128.

  • PDF

A study on sensing for abnormality of BUS BAR in motor control center (모터컨트롤센터의 BUS BAR 이상 감지를 위한 실험적 연구)

  • Kim, Sung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5838-5842
    • /
    • 2011
  • The study mainly aims to explore how deterioration of motor control center, namely MCC, and vibration put impact on temperature of bus bar as well as temperature change of bolt-nut joint. The motor control center consists of three internal parts (i.e. R, S, T) which are for motor operation of high capacity. Two dimensional mechanism for measuring temperature was designed and manufactured with infrared temperature sensor. Installing it in inner motor control center enabled researcher to monitor temperature of bus bar as well as amount of change of current regularly. Temperature change of bus bar according to load was primarily examined based on a bolted joint in the experiment. It was clearly verified that temperature change of bus bar was proportional to current consumption. Therefore, installing non-contact two dimensional mechanism for measuring temperature in motor control center would be expected to prevent temperature rise owing to overload current and power outage as well as fire accident which can be triggered by poor electrical contact.

A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank (저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.562-567
    • /
    • 2020
  • In this paper, this is a study on the correction of protection relays to monitor temporary power facilities for storage tanks especially transformers to block and protect faults such as insulation breakdown. When an abnormality such as a short circuit or a ground fault occurs in the power system, it is important to detect this quickly cut off the device and equipment in which the fault occurred and separate it from the power system to correct the protection relay so that it does not interfere with power supply. In addition the fault current calculation that accurately applies the fault type and the cause of the fault for protection cooperation will be the most important factor in the correction of the protection relay. For protection coordination a study was conducted on the method of coordination for protection of power facility protection for storage tanks such as over current relay, ground over current relay, under voltage relay, and ground over voltage relay applied to temporary.

An OLED Pixel Circuit Compensating Threshold Voltage Variation of n-channel OLED·Driving TFT (n-채널 OLED 구동 박막 트랜지스터의 문턱전압 변동을 보상할 수 있는 OLED 화소회로)

  • Chung, Hoon-Ju
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.3
    • /
    • pp.205-210
    • /
    • 2022
  • A novel OLED pixel circuit is proposed in this paper that uses only n-type thin-film transistors(TFTs) to improve the luminance non-uniformity of the AMOLED display caused by the threshold voltage variation of an OLED driving TFT. The proposed OLED pixel circuit is composed of 6 n-channel TFTs and 2 capacitors. The operation of the proposed OLED pixel circuit consists of the capacitor initializing period, threshold voltage sensing period of an OLED·driving TFT, image data voltage writing period, and OLED·emitting period. As a result of SmartSpice simulation, when the threshold voltage of·OLED·driving TFT varies from 1.2 V to 1.8 V, the proposed OLED pixel circuit has a maximum current error of 5.18 % at IOLED = 1 nA. And, when the OLED cathode voltage rises by 0.1 V, the proposed OLED pixel circuit has very little change in the OLED current compared to the conventional OLED pixel circuit. Therefore, the proposed pixel circuit exhibits superior compensation characteristics for the threshold voltage variation of an OLED driving TFT and the rise of the OLED cathode voltage compared to the conventional OLED pixel circuit.

The Characteristics analysis of a Flux-lock Type Fault Current Limiter according to the Winding Directions for Power Grid (전력계통 적용을 위한 결선방향에 따른 자속구속형 한류기의 특성 분석)

  • Lee, Mi-Yong;Park, Jeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5879-5884
    • /
    • 2013
  • With the rapid industrialization and economical development, the electricity demands of the industrial facilities and densely populated large cities are continuing to increase in Korea. The increase in the power consumption requires the extension of power facilities, but it is difficult to secure spaces for equipment installation in the limited space of urban areas. In addition, the 154 kV or 345 kV transmission systems in Korea has a short transmission distance, and are connected to one another in network structures that ensure the high reliability and stability of power supply. This structure reduces the impedance during the fault in power system, and increases the magnitude of in the short circuit fault current. The superconducting fault current limiter (SFCL) was devised to effectively address these existing problems. The SFCL is a new-concept eco-friendly protective device that ensures fast operation and recovery time for the fault current and does not need additional fault detection devices. Therefore, many studies are being conducted around the world. In this paper, based on the wiring method the initial fault current characteristics, current limiting characteristics, according to the incident angle and the change in inductance current limiting characteristics were analyzed in a multifaceted methods.

I-V Characteristics of a Methanol Sensor for Direct Methanol fUel Cell(DMFC) as a Function of Deposited Platinum(Pt) Thickness (직접 메탄올 연료전지용 메탄올 센서의 백금 두께의 변화에 따른 전류-전압 특성 변화)

  • Yang, Jin-Seok;Kim, Seong-Il;Kim, Chun-Keun;Park, Jung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.49-53
    • /
    • 2007
  • The direct methanol fuel cell (DMFC) is a promising power source for portable applications due to many advantages such as simple construction, compact design, high energy density, and relatively high energy-conversion efficiency. In this work, an electrochemical methanol sensor for monitoring the methanol concentration in direct methanol fuel cells was fabricated using a thin composite nafion membrane as the electrolyte. We have analyzed the I-V characteristic of the fabricated methanol sensor as a function of methanol concentration, catalyst electrode and platinum(Pt) thickness. The fabricated sensor was analyzed by I-V measurement with various methanol concentration. When we measured the sensor characteristics with 10nm Pt and at 1V, the current value was $1.30{\times}10^{-6}A,\;1.96{\times}10^{-6}A\;and\;2.80{\times}10^{-6} A$ for three methanol concentration of 1M, 2M and 3M, respectively. When the methanol concentration was fixed at 2M, the current value of the fabricated device with Pt layers of 5, 10 and 15 nm thickness was $3.06{\times}10^{-6}A,\;1.96{\times}10^{-6}A\;and\;1.00{\times}10^{-6}A$, respectively. These results lead us to the conclusion that when the methanol concentration increases, the output current increases and when the catalyst electrode become thinner, the current increase more. It showed that, the thinner the catalyst electrode, the more electrochemistry become activation.

  • PDF

Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System (고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is confirmed the unreliability of the existing RCD by electrical fault simulator and is proposed a Electrical Fire Disaster Prevention Device (EFDPD) by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the EFDPD has double protection function which operates self circuit breaker or rapidly cuts off the existing RCD. The proposed EFDPD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

Design of Inductive Power-line communication system with Earth current (접지전류를 이용한 유도형 전력선통신 시스템 설계)

  • Lee, Won-Ho;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1860-1861
    • /
    • 2011
  • 본 논문은 유도형 전력선통신 시스템을 구현하고자 한다. 이 시스템을 응용하여 현재의 수용 가구와 산업 현장에 적용 할 경우, 전력선 자체만으로 데이터 송신이 가능하기 때문에 전력선을 통신선으로 활용, 데이터를 송신하기 위한 접지 공사만으로, 현 각 수용 가구에 설치되어 있는 적산 전력계, 가스계량기, 수도 계량기가 디지털 계기로 대체되었을 경우 전력, 가스, 상수도의 누전 및 누수 등을 중앙 통제실에서 통계적 수치로 감지가 가능하므로 국가 에너지 자원의 효율적인 관리가 가능하다. 본 논문은 이 시스템의 타당성을 조사하기 위해 하드웨어를 제작하여 직접 송/수신 실험을 해보기로 한다.

  • PDF