• Title/Summary/Keyword: 전력 차단

Search Result 508, Processing Time 0.024 seconds

Development of optimal cross-section design methods for bored utility tunnels: case study of overseas typical cross-sections and design criteria (터널식 공동구 최적단면 설계기술 개발: 해외 표준단면 사례 및 설계기준 분석)

  • Park, Kwang-Joon;Yun, Kyoung-Yeol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1073-1090
    • /
    • 2018
  • Since the domestic utility tunnels were built mainly in the development project of the new city, they are all in the form of cut-and-cover box tunnel. But, in the case of overseas construction of utility tunnels for existing urban areas, the bored tunnel types are mainly adopted. It is reasonable to install bored tunnels in a downtown area because it is difficult to block the roads or install bypass roads due to heavy traffic and civil complaints. In order to activate the utility tunnels in bored type, it is necessary to secure optimized cross-sectional design technology considering the optimal supplying capacity and mutual influencing factors (Thermal Interference, electrolytic corrosion, efficiency of the maintenance, etc.) of utilities (power cables, telecommunication cables, water pipes, etc.). The optimal cross-section design method for bored utility tunnels is ultimately to derive the optimal arrangement technique for the utilities. In order to develop the design methods, firstly, the cases of tunnel cross-section (Shield TBM, Conventional Tunneling) in overseas shall be investigated to analyze the characteristics of the installation of utilities in the section and installation of auxiliary facilities, It is necessary to sort out and analyze the criteria related to the inner cross-section design (arrangement) presented in the standards and guidelines.

A 0.2V DC/DC Boost Converter with Regulated Output for Thermoelectric Energy Harvesting (열전 에너지 하베스팅을 위한 안정화된 출력을 갖는 0.2V DC/DC 부스트 변환기)

  • Cho, Yong-hwan;Kang, Bo-kyung;Kim, Sun-hui;Yang, Min-Jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.565-568
    • /
    • 2014
  • This paper presents a 0.2V DC/DC boost converter with regulated output for thermoelectric energy harvesting. To use low voltages from a thermoelectric device, a start-up circuit consisting of native NMOS transistors and resistors boosts an internal VDD, and the boosted VDD is used to operate the internal control block. When the VDD reaches a predefined value, a detector circuit makes the start-up block turn off to minimize current consumption. The final boosted VSTO is achieved by alternately operating the sub-boost converter for VDD and the main boost converter for VSTO according to the comparator outputs. When the VSTO reaches 2.4V, a buck converter starts to operate to generate a stabilized output VOUT. Simulation results shows that the designed converter generates a regulated 1.8V output from an input voltage of 0.2V, and its maximum power efficiency is 60%. The chip designed using a $0.35{\mu}m$ CMOS process occupies $1.1mm{\times}1.0mm$ including pads.

  • PDF

A Study on Improvement of Directional Errors for K-MLRS Launcher (천무 발사대 방향성 오류현상 개선에 관한 연구)

  • Kim, Hyeeun;Kim, Minchang;Yu, Hanjun;Bae, Gongmyeong;Oh, Eunbin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.705-713
    • /
    • 2021
  • Because the cage assembly serves as the launch platform, an accurate aim is essential to ensure shooting accuracy for the target. On the other hand, the abnormal rotation of the cage due to the directional errors of the K-MLRS has continuously caused quality problems. The quality problem of weapon systems may have a negative impact on the military's power loss. In this study, improvement plans were derived by examining the defects and analyzing the directional errors of the K-MLRS launcher. In addition, all possible causes of directional errors were derived from the flow diagram for cage directionality. Based on the results, the defense design through the software program was intended to prevent the loss of direction. Through this study, the signal error of the resolver was improved by preventing unspecific signals in the data. Furthermore, the directional judgment method was improved to minimize the impact of data distortion. Lastly, directional storage and verification methods were improved so that data for the cage rotation direction would not be affected by errors. For the design improvement method, the reliability was verified through the system applicability. This study is expected to be a reference for failure analysis and design for similar weapon systems in the future.

A study for Information Security Risk Assessment Methodology Improvement by blockade and security system level assessment (봉쇄와 보안장비 수준평가를 통한 정보보호 위험평가 개선 연구)

  • Han, Choong-Hee;Han, ChangHee
    • Convergence Security Journal
    • /
    • v.20 no.4
    • /
    • pp.187-196
    • /
    • 2020
  • In order to manage information security risk, various information security level evaluation and information security management system certification have been conducted on a larger scale than ever. However, there are continuous cases of infringement of information protection for companies with excellent information security evaluation and companies with excellent information security management system certification. The existing information security risk management methodology identifies and analyzes risks by identifying information assets inside the information system. Existing information security risk management methodology lacks a review of where cyber threats come from and whether security devices are properly operated for each route. In order to improve the current risk management plan, it is necessary to look at where cyber threats come from and improve the containment level for each inflow section to absolutely reduce unnecessary cyber threats. In addition, it is essential to measure and improve the appropriate configuration and operational level of security equipment that is currently overlooked in the risk management methodology. It is necessary to block and enter cyber threats as much as possible, and to detect and respond to cyber threats that inevitably pass through open niches and use security devices. Therefore, this paper proposes additional evaluation items for evaluating the containment level against cyber threats in the ISMS-P authentication items and vulnerability analysis and evaluation items for major information and communication infrastructures, and evaluates the level of security equipment configuration for each inflow.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.

A Study on Effect of B/L's Exemption Clauses Relating to the Governing Law of English Law (영국법의 준거법과 관련한 선하증권 면책약관의 효력에 관한 연구)

  • Han, Nak-Hyun;Jung, Jun-Sik
    • Journal of Korea Port Economic Association
    • /
    • v.22 no.4
    • /
    • pp.1-17
    • /
    • 2006
  • In the Bill of Lading of The Irbenskiy Proliv is not subject to the Hague-Visby Rules in accordance with paragraphs (A) and/or (E) of cl.1 or to the Hague Rules in accordance with paragraphs (B) and/or (D) of cl.1. The Irbenskiy Proliv is very rare case that is effective to exempt the carrier as literal words of Bill of Lading. The action concerns cargoes of perishable goods shipped from Brazil to Japan, under Bills of Lading each of which contained an extensive carrier's exemption clause. A preliminary issue was ordered to be determined on the question whether c1.4 is effective to exempt the ralliers from any potential liability for the claims in this case. The court held that there is no reason to reject c1.4 as part of each of the contracts contained in or evidenced by the bills of lading; and it protects the carrier where damage to the goods shipped results from such causes. It is therefore effective to exempt the carriers from any potential liability for those claims.

  • PDF

A Study on Termite Monitoring Method Using Magnetic Sensors and IoT(Internet of Things) (자력센서와 IoT(사물인터넷)를 활용한 흰개미 모니터링 방법 연구)

  • Go, Hyeongsun;Choe, Byunghak
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.206-219
    • /
    • 2021
  • The warming of the climate is increasing the damage caused by termites to wooden buildings, cultural properties and houses. A group removal system can be installed around the building to detect and remove termite damage; however, if the site is not visited regularly, every one to two months, you cannot observe whether termites have spread within, and it is difficult to take prompt effective action. In addition, since the system is installed and operated in an exposed state for a long period of time, it may be ineffective or damaged, resulting in a loss of function. Furthermore if the system is installed near a cultural site, it may affect the aesthetic environment of the site. In this study, we created a detection system that uses wood, cellulose, magnets, and magnetic sensors to determine whether termites have entered the area. The data was then transferred to a low power LoRa Network which displayed the results without the necessity of visiting the site. The wood was made in the shape of a pile, and holes were made from the top to the bottom to make it easier for termites to enter and produce a cellulose sample. The cellulose sample was made in a cylindrical shape with a magnet wrapped in cellulose and inserted into the top of a hole in the wood. Then, the upper part of the wood pile was covered with a stopper to prevent foreign matter from entering. It also served to block external factors such as light and rainfall, and to create an environment where termites could add cellulose samples. When the cellulose was added by the termites, a space was created around the magnet, causing the magnet to either fall or tilt. The magnetic sensor inside the stopper was fixed on the top of the cellulose sample and measured the change in the distance between the magnet and the sensor according to the movement of the magnet. In outdoor experiments, 11 cellulose samples were inserted into the wood detection system and the termite inflow was confirmed through the movement of the magnet without visiting the site within 5 to 17 days. When making further improvements to the function and operation of the system it in the future, it is possible to confirm that termites have invaded without visiting the site. Then it is also possible to reduce damage and fruiting due to product exposure, and which would improve the condition and appearance of cultural properties.