• Title/Summary/Keyword: 전력 시스템(power system)

Search Result 5,984, Processing Time 0.041 seconds

ICT based Wireless Power Transmission System Development (ICT 기반의 무선전력전송 시스템 개발)

  • Lee, Jong-Hee;Bang, Junho;Chun, Hyun-Jun;Seo, Beom-Geun;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • Recently, wireless power transmission has attracted much interest and is the subject of much research in industry and academia. As its name implies, it is a technology which involves transferring power without wires. This paper presents the design of an ICT-based wireless power transmission system. The proposed system consists of a wireless transceiver unit and high-efficiency coil unit, which can increase both the transmission efficiency and the effective power distance. In particular, the wireless transceiver unit was designed to work with the ICT technique to enable real-time remote monitoring. Also, studies were done relating to the effect of reducing the standby power. The optimal frequency of IGBT devices used in industrial wireless power systems of 20[KHz] was utilized. The values of $23.9[{\mu}H]$ and $2.64[{\mu}F]$ were selected for L and C, respectively, through many field experiments designed to optimize the system design. In addition, an output current controlling algorithm was developed for the purpose of reducing the standby power. The results presented in this paper represent a 75[%] to 85[%] higher power transmission efficiency with a 10[%] increase in the effective power transmission distance compared with the existing systems. As a result, the proposed system exhibits a lower standby power and maintenance costs. Also, the designed wireless transceiver unit facilitates fault detection by means of user acquired data with the development of the ICT applied program.

A Study on the Implementation of 9.6Kbps Power Line Communication System for Smart Home (스마트 홈용 9.6Kbps급 전력선 통신 시스템 구현에 관한 연구)

  • Kim, Chul;Jeong, Young-Hwa
    • The Journal of Information Technology
    • /
    • v.6 no.4
    • /
    • pp.81-91
    • /
    • 2003
  • This paper is concerned with the implementation of power line communication system with 9.6Kbps. This system is suitable to establish the smart home using the power line having been installed in house. In the suggested power line communication system, we use the chirp signal with a linearity and spread spectrum frequency band of 100KHz~200KHz. We had the performance experiment for the implementation system. The experiment was achieved in the pseudo load network similar to real circumstance of power line communication. As the result, the communications under the circumstance were accomplished satisfactorily. We confirmed that the suggested 9.6Kbps power line communication system with the Chirped-SS method had the performance enough to commercialize the smart home.

  • PDF

Implementation of 1.7MHz, 25W Wireless Power Transmission(WPT) System using Coupled Magnetic Resonance (1.7MHz, 25W급 자기공명 무선전력 전송 시스템 구현)

  • Kim, Seong-Min;Cho, In-Gui;Moon, Jung-Ick
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.317-323
    • /
    • 2013
  • In this paper, 25W wireless power transmission(WPT) system using the coupled magnetic resonance is presented. The WPT system consists of a 100W class-F power transmitter, 1.7MHz magnetic resonators and a 40W full-bridge receiver using diodes. Especially, the transmit power control function using the 400MHz FSK communication between the transmitter and the receiver is adopted in the proposed system for the stable power transmission. Using the system and the power control function, the WPT system can be adopted in the various electronic devices and the commercialization of WPT system can be moved forward.

Linked operation between energy management system(EMS) and market operation system(MOS, CBP) (계통운영시스템(EMS)과 시장운영시스템(MOS,CBP)간 연계운영)

  • Park, Bong-Yong;Kim, Myung-Woong;Ahn, Jae-Seung;Kim, Min-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.547_548
    • /
    • 2009
  • 전력거래소에서 전력계통 및 전력시장 운영을 위해 도입한 핵심시스템은 EMS, MOS, CBP 이다. 이 세개 시스템은 각각 고유의 기능을 가진 별도의 시스템으로 구축되었다. 우리나라의 전력시장이 발전경쟁단계에 머무르면서 당초 양방향전력시장용으로 도입된 MOS시스템이 활용되지 못함에 따라 MOS시스템의 실시간 급전기능을 활용해 전력계통 운영의 안정성 및 경제성 향상을 꾀하고자 이 세 개의 시스템을 2006년 10월부터 연계 운영하고 있다. 이를 위해 CBP입찰값을 MOS의 입찰형식으로 변환하기위한 CBP-MOS 입찰변환시스템, 실시간 수요예측을 위한 수요예측 프로그램, MOS와 EMS를 일괄적으로 연계하기 위한 연계Mode, 각 발전기 운전원들에게 발전기의 급전계획값 및 실시간 운전현황을 전송하기 위한 급전지시시스템(MX) 및 전반적인 시스템 연계운영을 종합적으로 감시하기 위한 종합감시시스템 등을 개발하여 운영하고 있다.

  • PDF

Technology Development for Stabilization of PV Independent System (태양광발전시스템 독립계통 안정화 기술개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.5
    • /
    • pp.181-186
    • /
    • 2019
  • In order to reduce the fossil fuels consumed in conventional commercial independent diesel generators in the same environment as the island area, it is necessary to develop a photovoltaic system that will bear more than 40% of the independent system capacity. For this development, it is necessary to develop a high-capacity inverter that can improve the stability of the independent system installed in the island area and supply high-quality power to the load. In addition, the EMS power generation control system for the independent grid photovoltaic power generation system is a parallel operation power control system of the diesel generator connected with the solar power generation system. It controls the output of the diesel generator according to the load ratio and the solar power generation, A stable supply system is needed. This independent grid photovoltaic generation system can increase the solar power supply to the independent system area and increase the power stability of the independent system and further reduce the use of fossil fuel due to the ineffective power control of the independent system. It is expected that the economy will be secured early.

Improved Operating Method of Utility Interactive PV System for Peak Power Cut Effect (첨두부하 삭감효과를 갖는 UIPV시스템의 개선된 운용방법)

  • Kim, Young-Sik;Bayasgalan, Dugarjav;Heo, Hye-Seong;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.415-422
    • /
    • 2009
  • This paper describes the UIPV(Utility Interactived Photovoltaic) system which can improve the peak-cut effect by adding energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and application algorithm has been applied to UIPV system which is based on working PV system during 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. Also the proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve.

An Isolated Power System Based on Variable Speed Engine Generator with Super-capacitor (슈퍼캐패시터와 가변속 엔진발전기를 이용한 독립형 전원 시스템)

  • Lee, Joon-Hwan;Lee, Seung-Hwan;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.128-134
    • /
    • 2008
  • The variable speed engine generator set is interested for an isolated power system due to reduced fuel consumption and less emission. However, because of sluggish dynamic behavior of the internal combustion engine the power quality would be degraded during the sudden load power surge, where the power required by the load is not available by the engine due to the reduced engine speed. An isolated power system based on variable speed engine with a super-capacitor bank can improve dynamic characteristics under such a sudden load change, and power quality, fuel consumption, and pollutants can be improved remarkably. Also, it is verified by the computer simulation that the inverter of 3phase-4leg is compatible to the isolated power system with unbalanced load. In this paper, the feasibility of the system has been verified based on a 26kw commercial diesel engine system.

A Study on the Design and Analysis of High Frequency Coil Shape for Contactless Power Transmission System Combined with Transfer System (이송시스템이 결합된 비접촉 전력전송 시스템용 고주파 코일 형상 설계 및 해석에 관한 연구)

  • Kim, TaeKue;Joo, ChangDae;Ahn, HoKyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.26 no.1
    • /
    • pp.41-54
    • /
    • 2021
  • There is a difficulty in improving the working environment and technological advancement due to power supply through cables in the application of linear motors of robots and transfer systems applied in the existing manufacturing industry. We have studied the shape of the high-frequency coil for contactless power transmission system and characteristics of power conversion system, based on the magnetic field analysis of 2D and 3D, using the FEM-based physical analysis program.

Development of Power Consumption Consulting System Based on AMR Data in Power Industry (전력산업에서의 원격검침 데이터 기반 전력소비 컨설팅 시스템 개발)

  • Kim, Sun-Ic;Ko, Jong-Min;Jang, Moon-Jong;Yu, In-Hyeob;Yang, Il-Kwon;Cho, Sun-Gu;Yang, Won-Chul;Kim, Jae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2126-2127
    • /
    • 2006
  • 전력산업에서의 전력부가서비스는 전력공급자 중심의 서비스에서 전력소비자 중심의 서비스로 패러다임 변화가 가속화되면서, 전력소비자의 수요패턴을 가장 잘 나타내고 있는 원격검침데이터를 활용한 서비스가 크게 부각되고 있으며, 그 활용 영역도 폭 넓게 적용되고 있다. 본 논문에서는 원격검침 데이터 기반 전력부가서비스 Pilot 시스템의 일종인 "전력소비 컨설팅 시스템(Power Consumption Consulting System)" 개발 사례를 소개한다. 본 시스템의 주요 기능은 데이터 분석, 에너지 분석, 비용 분석 등과 같이 3가지로 분류 할 수 있으며, 원격검침을 시행중인 고압고객 중 계약전력이 100kW 이상인 대수용가로부터 특히, 요금절감을 필요로 하지만 별도의 설비나 인력을 보유하지 않은 10,000kW 이하 고객을 적용대상으로 하고 있다.

  • PDF

An ICCP Application Method for an Error Decrease of the Power Control Communication System (전력제어 통신 시스템의 에러 감소를 위한 ICCP 적용 방안)

  • 김종빈;정래성
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.9
    • /
    • pp.349-357
    • /
    • 2003
  • Because of capacity of the electric power equipment grew larger and the electric power system was complicated, it was required a protocol to process data without the errors in order to supply the high quality and stable electric power. However, HDLC and TCP/IP communication protocol using between Seoul EMS and Kwangju RCC (or between RCC and SCC) is decreasing reliability by the delay of speed and the occurrence of errors. In this paper, we applied ICCP(Inter-Control Center Communication Protocol) communication protocol in order to improve them and implemented an electric power communication system for remote control of the electric power equipment. Also, we modified program for error correction and implemented the system using the most suitable BLT. The errors were more decreased in case of ICCP protocol than HDLC protocol and TCP/IP protocol applied to the electric power communication system.