• Title/Summary/Keyword: 전력품질개선

Search Result 226, Processing Time 0.024 seconds

Grid-interactive Small Battery Energy Storage System with High Power Quality and Demand Side Management (전력품질 개선 및 부하 분담 기능을 갖는 계통 연계형 소규모 에너지 저장 시스템)

  • Ko Sung-Hun;Shin Young-Chan;Lee Seong-Ryong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.8
    • /
    • pp.387-394
    • /
    • 2005
  • This paper deals with the grid-interactive small battery energy storage system, which aims at the integration o( power quality improvement and demand side management. The main purpose of the proposed system is to achieve the peak power cutting and to compensate the current harmonics and reactive power at the point of installation on power distribution for residential homes. paper deals with the grid-interactive small battery energy storage system, In this paper, the basic principle and control algorithm is analyzed, theoretically and the design methodology of the system is discussed. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1 KVA load capacity is presented.

A New Phase Locked Loop(PLL) Strategy Suitable to UPS (무정전전원장치에 적합한 새로운 전원각 정보 추출 기술)

  • Ji Jun-Keun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.198-202
    • /
    • 2004
  • 본 논문에서는 전력 품질 기기의 제어에 있어서 필수적 요소라고 할 수 있는 전원각을 찾는 방법 중에서 PLL에 관하여 기존의 방식들을 먼저 알아보고, UPS 시스템에 적용하기에 적합한 새로운 PLL 방식을 제안하며, 컴퓨터 시뮬레이션을 통해 기존의 방식과의 성능 비교를 통해서 제안된 새로운 PLL 방식의 우수성을 입증한다. 본 논문에서는 기존의 정상분을 추출하여 이용하는 PLL 방식을 UPS에 적합한 형태로 개선한 주파수를 제안한 PLL 방식을 제안하였다. 이 PLL 방식은 기존의 PI 제어기에 주파수 제한기(limiter)와 안티 와인드업(anti-wind up)을 추가하였다. 이것의 기본적인 동작 원리는 기존의 방법들과 같지만, 차이점은 주파수 제한기의 삽입으로 인하여 주파수 변동률을 일정한 범위 내에서 제한할 수 있다는 것이다. 기존의 PLL 방법과 본 논문에서 제안된 주파수를 제한한 PLL 방법의 차이를 알아보기 위하여 동적 전압 보상기로 전압을 보상하는 시뮬레이션을 하였고, 결과적으로 제안된 주파수를 제한한 PLL 방법이 기존의 PLL 방법보다 UPS에 적합함을 입증하였다.

  • PDF

Design and performance evaluation of optimum TCM combined with CPM signals in the frequency-selective fading channel (주파수 선택성 페이딩 채널에서 CPM 신호와 결합된 최적 TCM의 설계 및 성능 평가)

  • 정영모;이상욱;심수보
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.6
    • /
    • pp.1064-1074
    • /
    • 1994
  • In this paper, an optimum TCM(trellis coded modulation)combined with CPM(continuous phase modulation) signal is investigated, and the performances are evaluated on the two-ray fading channel, which is one of the well-known frequency-selected because of their relatively good power and spectrum efficiency, and the modulation index is varied from 0.1 to 0.6. The performance is evaluated for each modulation index. The constraint length of the encoder, which is comprised in TCM, is chosen to be 2 and 3. From the performance evaluations, when the constraint length is 3 and modulation index 0.5, a power gain if the optimum TCM over the scheme without coding is observed to be 2.0dB for 1REC and 2.1dB for 3RC, respectively, on the fading channel. Thus, a significant improvement on the line quality is expected when the optimum TCM presented in this paper is employed in digital mobile radio applications.

  • PDF

Analysis of Control Algorithm for Instantaneous Voltage Sag Corrector (순시적인 전압 sag 보상기에 대한 제어 알고리즘의 해석)

  • 이상훈;김재식;최재호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.173-179
    • /
    • 2001
  • This paper represents the control algorithm of the instantaneous voltage sag corrector for the power quality enhancement in distribution line. Especially, a novel detection technique of the symmetrical components is proposed for the analysis of the three-phase unbalanced and asymmetrical problems caused by the single line ground fault which is he most frequent event. This proposed method is based on the simple calculation and the control references of the symmetrical components for voltage compensation can be described as dc value without any other phase detection procedure. And also, for the generation of the reference voltages, the UF and MF defined by IEC is considered. Using this proposed control algorithm, the compensator has the fast dynamic characteristics and the THD of the compensated voltage waveform is very low. Finally, the validity of the proposed algorithm is proved by the PSCAD/EMTDC simulation and experimental results.

  • PDF

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

Quality and Combustion Characteristics of Miscanthus Pellet for Bioenergy (바이오에너지용 억새 펠릿의 품질 및 연소 특성)

  • Moon, Youn-Ho;Lee, Ji-Eun;Yu, Gyeong-Dan;Cha, Young-Lok;Song, Yeon-Sang;Lee, Kyeong-Bo
    • Clean Technology
    • /
    • v.22 no.4
    • /
    • pp.286-291
    • /
    • 2016
  • In this study we made fuel pellet from miscanthus biomass and investigated changes of physiological characteristics and electricity consumption of pelletizing process in comparison with fuel pellet made of pine sawdust. We also examined combustion characteristics including ash content and clinker forming ratio with fuel pellet made of mixing with micanthus biomass and lime powder. Bulk density of ground-miscanthus and pine sawdust were $158g\;L^{-1}$ and $187g\;L^{-1}$, respectively. Bulk density of ground miscanthus was lower than that of pine sawdust, but increased to $653g\;L^{-1}$ after pelletizing, which was similar to $656g\;L^{-1}$ of pine sawdust pellet. Moisture content in raw miscanthus and ground miscanthus were 17.0% and 11.8%, respectively. Moisture content in ground miscanthus was similar to that of pine saw dust and decreased to 6.73% after pelletizing, which was 7.7% lower than that of pine sawdust pellet. Although $27kWh\;ton^{-1}$ were required for compaction press that was an additional process in miscanthus pelleitizing, total required electricity was $193kWh\;ton^{-1}$ which was similar to $195kWh\;ton^{-1}$ of pine sawdust pellet pelleitizing. Pellet durability and pelletizing ratio of miscanthus were 98.0% and 99.7%, respectively, which were similar to 98.1% and 99.4% of pine sawdust pellet. When lime mixing ratio increased, ash melting degree and clinker forming ratio of miscanthus pellet increased. While higher heating value and clinker forming ratio of miscanthus pellet decreased.

The Research On the Energy Storage System Using SuperCapacitor (슈퍼커패시터를 적용한 에너지 저장시스템 설계에 관한 연구)

  • Kim, IL-Song
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.11
    • /
    • pp.215-222
    • /
    • 2018
  • In this paper, the research on the energy storage system adapting super-capacitor has been performed. The most advanced features compared to the conventional lead-acid battery systems is that it can obtain high power capability due to the super capacitor power characteristics. The suggested system can attain high power in short times and achieve high power quality improvements. The application areas are power quality improvement system, motor start power which requires high power during transient times. The energy conversion system consists of bi-directional converter and inverter and advantages of high speed, high power charging and discharging performances. The design steps for the two loop controller of the bi-directional inverter are suggested and verified by the experiment and manufacturing. The two loop controller design starts from linearized transfer function which is calculated from the state averaging model including state decoupling method. The current controller requirements are 20% overshoot and settling time and voltage controller are no overshoot and settling time which is 10 times longer than current controller. The design is verified from the step input response. The designed controllers have unity power factor characteristics and thus can improve the power quality of the grid. It also has fast response time and zero steady state error.

The Signal-to-Noise Ratio Enhancement of the Satellite Electro-Optical Imager using Noise Analysis Methods (영상센서신호의 잡음분석을 이용한 위성용 전자광학탑재체의 신호대잡음비 개선 방법)

  • Park, Jong-Euk;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.159-169
    • /
    • 2017
  • The Satellite Electro-Optic Payload System needsspecial requirements with the conditions of limited power consumption and the space environment of solar radiation. The acquired image quality should be mainly depend on the GSD (Ground Sampled Distance), SNR (Signal to Noise Ratio), and MTF (Modulation Transfer Function). On the well-manufactured sensor level, the thermal noise is removed on ASP (Analog Signal Processing) using the CDS (Corrective Double Sampling); the noise signal from the image sensor can be reduced from the offset signals based on the pre-pixels and the dark-pixels. The non-uniformity shall be corrected with gain, offset, and correction parameter of the image sensor pixel characteristic on the sensor control system. This paper describes the SNR enhancement method of the satellite EOS payload using the mentioned noise remove processes on the system design and operation, which is verified by tests and simulations.

Adaptive Power Control Schemes for Interference Mitigation in LTE Femtocell Networks (LTE 기반 펨토셀 네트워크에서 간섭 완화를 위한 적응적 전력 제어 기법)

  • Lee, Sang-Joon;Kim, Seung-Yeon;Lee, Hyong-Woo;Ryu, Seung-Wan;Cho, Choong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8A
    • /
    • pp.648-660
    • /
    • 2012
  • The low-power, low-cost femtocell network has been proposed not only to alleviate traffic load to the macro base station (eNB) but also to cover the indoor coverage hole problem. However, in the dense femtocell environment where many femtocells are deployed to cover the whole large office building, performance of such femtocell environment can be deteriorated due to severe co-channel interference problem between the eNB and femtocells and among neighboring femtocells. In particular, a macro UE(mUE) located within femtocell coverage may experience severe co-channel interference from surrounding femtocells. Therefore, In this paper, we propose a novel power control schemes to mitigate interference to a mUE under such dense LTE femtocell environment. With proposed femtocell power control schemes, performance of the mUE can be greatly improved in terms of the outage probability and the SINR while maintaining satisfying femtocell performance. Simulation based performance study shows that the proposed power control scheme is able to enhance mUE performance more than 30% than the conventional dense femtocell in terms of the two performance metrics.

Hardware optimized high quality image signal processor for single-chip CMOS Image Sensor (Single-chip CMOS Image Sensor를 위한 하드웨어 최적화된 고화질 Image Signal Processor 설계)

  • Lee, Won-Jae;Jung, Yun-Ho;Lee, Seong-Joo;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.5
    • /
    • pp.103-111
    • /
    • 2007
  • In this paper, we propose a VLSI architecture of hardware optimized high quality image signal processor for a Single-chip CMOS Image Sensor(CIS). The Single-chip CIS is usually used for mobile applications, so it has to be implemented as small as possible while maintaining the image quality. Several image processing algorithms are used in ISP to improve captured image quality. Among the several image processing blocks, demosaicing and image filter are the core blocks in ISP. These blocks need line memories, but the number of line memories is limited in a low cost Single-chip CIS. In our design, high quality edge-adaptive and cross channel correlation considered demosaicing algorithm is adopted. To minimize the number of required line memories for image filter, we share the line memories using the characteristics of demosaicing algorithm which consider the cross correlation. Based on the proposed method, we can achieve both high quality and low hardware complexity with a small number of line memories. The proposed method was implemented and verified successfully using verilog HDL and FPGA. It was synthesized to gate-level circuits using 0.25um CMOS standard cell library. The total logic gate count is 37K, and seven and half line memories are used.