• Title/Summary/Keyword: 전력품질개선

Search Result 226, Processing Time 0.026 seconds

Installation and Demonstration of 1 MVA STATCOM (1 MVA STATCOM의 설치 및 실증운전)

  • Lee, Doo-Young;Jung, Hong-Ju;Kim, June-Sung;Choi, Jong-Yun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.160-161
    • /
    • 2012
  • (주)효성에서 자체 설계 및 개발한 FACTS(Flexible ACTransmission System) 기기중 하나인 1 MVA STATCOM(Static synchronous Compensator)은 전압 안정도 개선 및 역률제어를 통해 계통전력품질을 향상시킨다. 현재 개발된 1 MVA STATCOM은 제주 행원 풍력단지 내 풍력 발전기 14호기가 연계된 22.9 kV 계통에 병렬접속 되어있으며 현재 실증 운전 중에 있다. 본 논문에서는 1 MVA STATCOM의 설치 및 실증 운전사례를 소개한다.

  • PDF

Development of 1MVA STATCOM for Wind Farm (풍력단지 적용을 위한 1MVA STATCOM 개발)

  • Jung, HongJu;Shin, HyunJin;Yeo, SangMin;Park, JungSoo;Lee, JeongMin;Suh, InYoung
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.288-289
    • /
    • 2010
  • 다양한 신재생에너지의 발전원 확보를 위해서는 발전원의 출력 안정화가 필수적으로 수반되어져야 한다. 본 논문은 다양한 신재생에너지 발전원의 안정화를 위한 핵심기기 중 하나인 STATCOM의 설계 및 제작에 관한 내용이다. 개발 진행 중인 1MVA STATCOM은 제주도 행원 풍력발전의 전력품질을 개선하기 위해 설치될 예정으로 3-Level 인버터로 구성된 Stack과 LC 필터 그리고 변압기와 수배전반으로 구성되어 있다.

  • PDF

The Development of An Improved Distribution Automation System Including Low Voltage Monitoring Function (저압 배전망 감시기능을 포함하는 개선된 배전자동화시스템 개발)

  • Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1034-1041
    • /
    • 2007
  • This paper presents the developing results of improved distribution automation system including system configuration and subsystem design, prototype hardware and software implementation, and pilot tests on the real distribution networks of Korea Electric Power Corporation (KEPCO). An integrated system is designed to combine independent system for the distribution field works with DAS; transformer monitoring, power quality monitoring, voltage monitoring, outage monitoring, etc. The communication network is hierarchically configured as main network and branch network and well-defined integrated terminal units were developed. In addition, useful host configuration and applications were developed to integrate the services with DAS or interfacing other systems. Pilot tests were performed to verify that the system enables to properly integrate the DAS and other services of the distribution network.

  • PDF

Electric power facility status and analysis of operation results for Korea Superconducting Tokamak Advanced Research (KSTAR 대전력 설비 현황 및 운전결과 분석)

  • Kong, Jong-Dae;Hong, Seong-Lok;Hwang, In-Seong;Kim, Yaung-Soo;Eom, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.85_86
    • /
    • 2009
  • 핵융합반응은 초고온의 플라즈마 상태에서 가벼운 원자핵들이 융합하여 무거운 원자핵으로 바뀌는 현상으로, 이 과정에서 감소된 질량이 막대한 에너지로 변환되는데 이를 핵융합에너지라고 한다. 핵융합에너지는 인류의 에너지 위기를 극복할 수 있는 최적의 대체에너지이며, 무한, 청정, 고효율에너지이다. 이에 국가핵융합연구소(NFRI)는 Green Energy 의 개발과 핵융합에너지 상용화 기술을 개발하기 위해 핵융합연구장치인 KSTAR(Korea Superconducting Tokamak Adavanced Research)를 제작하여 장치의 운전연구 및 기술 확보에 힘을 쏟고 있다. 또한 핵융합 관련 파생기술을 활용한 첨단 신사업 창출에 기여하고 있다. 본 논문에서는 KSTAR 1st Plasma 실험 시 KSTAR 장치에 전력을 공급하기 위한 전력설비 현황, 전력품질분석, 전력사용량 분석을 통해 향후 KSTAR 장치 운전을 위해 필요한 수전설비 증설, 무효전력보상장치 증설 등과 같은 전력계통의 효율화와 안정화를 위한 개선사항에 대해 기술하였다.

  • PDF

An Advanced Dead-Time Compensation Method for Dual Inverter with a Floating Capacitor (플로팅 커패시터를 갖는 이중 인버터를 위한 향상된 데드 타임 보상 기법)

  • Kang, Ho Hyun;Jang, Sung-Jin;Lee, Hyung-Woo;Hwang, Jun-Ho;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.271-279
    • /
    • 2022
  • This paper proposes an advanced dead-time compensation method for dual inverter with a floating capacitor. The dual inverter with floating capacitor is composed of double two-level inverters and a bulk electrolytic capacitor. The output voltage of the dual inverter is dropped by the conduction voltage of the power semiconductors. The voltage drop and dead-time cause the fundamental and harmonic distortions of output currents. When supplied power for OEW-load is low, the dual inverter operates as single inverter for effective operation. The dead-time compensation method for the dual inverter operated as single inverter is needed for reliability. The proposed method using band pass filter in this paper compensates dead-time, dead-time error and changed voltage drop error of power semiconductors for the dual inverter and dual inverter operated as single inverter. The effectiveness of the proposed method is verified by simulation results.

A Study on Improvement of Directional Errors for K-MLRS Launcher (천무 발사대 방향성 오류현상 개선에 관한 연구)

  • Kim, Hyeeun;Kim, Minchang;Yu, Hanjun;Bae, Gongmyeong;Oh, Eunbin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.705-713
    • /
    • 2021
  • Because the cage assembly serves as the launch platform, an accurate aim is essential to ensure shooting accuracy for the target. On the other hand, the abnormal rotation of the cage due to the directional errors of the K-MLRS has continuously caused quality problems. The quality problem of weapon systems may have a negative impact on the military's power loss. In this study, improvement plans were derived by examining the defects and analyzing the directional errors of the K-MLRS launcher. In addition, all possible causes of directional errors were derived from the flow diagram for cage directionality. Based on the results, the defense design through the software program was intended to prevent the loss of direction. Through this study, the signal error of the resolver was improved by preventing unspecific signals in the data. Furthermore, the directional judgment method was improved to minimize the impact of data distortion. Lastly, directional storage and verification methods were improved so that data for the cage rotation direction would not be affected by errors. For the design improvement method, the reliability was verified through the system applicability. This study is expected to be a reference for failure analysis and design for similar weapon systems in the future.

Harmony Search for Virtual Machine Replacement (화음 탐색법을 활용한 가상머신 재배치 연구)

  • Choi, Jae-Ho;Kim, Jang-Yeop;Seo, Young Jin;Kim, Young-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.26-35
    • /
    • 2019
  • By operating servers, storage, and networking devices, Data centers consume a lot of power such as cooling facilities, air conditioning facilities, and emergency power facilities. In the United States, The power consumed by data centers accounted for 1.8% of total power consumption in 2004. The data center industry has evolved to a large scale, and the number of large hyper scale data centers is expected to grow in the future. However, as a result of examining the server share of the data center, There is a problem where the server is not used effectively such that the average occupancy rate is only about 15% to 20%. To solve this problem, we propose a Virtual Machine Reallocation research using virtual machine migration function. In this paper, we use meta-heuristic for effective virtual machine reallocation. The virtual machine reallocation problem with the goal of maximizing the idle server was designed and solved through experiments. This study aims to reducing the idle rate of data center servers and reducing power consumption simultaneously by solving problems.

Control of DSTATCOM using "Direct" Output Control (직접 출력전압 제어 기술을 이용한 DSTATCOM의 제어)

  • Jung, Soo-Young;Moon, Seung-Il;Kim, Tae-Hyun;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.81-83
    • /
    • 2001
  • 본 논문에서는 EMTDC/PSCAD 패키지를 이용하여 배전용 정지형보상기(DSTATCOM)의 모델을 제안하였고, 이를 비선형 부하를 가지는 배전계통의 전력품질 향상을 위해 "직접" 출력전압 제어 기술을 적용하였다. 1선 지락 사고시에 본 논문에서 제시한 방법을 이용한 시뮬레이션을 통해 전압 파형이 개선되고, 고조파가 감소되며, 선로 전압 조정을 할 수 있음을 보였다.

  • PDF

Pixel driving method of OLED(Organic Light-Emitting Diode) Display (OLED 디스플레이 픽셀 구동방식)

  • Lee Jung-Ho;Chae Kyu-Su;Kim Min-Nyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.154-156
    • /
    • 2004
  • 고도의 정보가 집약되고 응용되기 시작하면서 정보를 표현하고자 하는 방법에 대한 연구는 더욱 절실히 요구되고 있다. 자연색에 가까운 고품질의 색상의 화면을 제공하기 위해 디스플레이의 무게와 크기, 전력소모 등의 많은 부분에 대해 연구가 진행되고 있다. 본 논문에서는 이러한 모든 기능을 충족시켜주는 차세대 디스플레이인 OLED(Organic Light-Emitting Diode)에 대한 구동 드라이브를 디지털 회로에 응용하고자 정확한 동작에 필요한 방법에 대해 소개하고 개선점에 대한 연구를 하였다.

  • PDF

Harmonics reduction by accuracy of DC shaping of power converters (전력변환장치의 직류 파형 개선을 통한 고조파 저감)

  • Kim, Jongsu;Ahn, Jaehong;Kim, Seonghwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1131-1136
    • /
    • 2014
  • Recently, power converters installed on the specialized vessels such as LNG Carrier and Icebreaker and offshore plants mainly use diode rectifier. However, such devices cause distortion of supply voltage waveform by involving much harmonics to input current of non linearity load in rectifying operation. Distortion of supply voltage waveform can be problems such as false operation of generator, transformer and load device and deterioration of power quality. This thesis is focusing with a view to producing accurate sinusoidal AC waveform with certain load through improvement of distortion of current waveform causing under operation of rectifier by using accurate circuit of DC shaping. The result of computer simulation proved that harmonics involved in current and voltage waveform of power system can be reduced.