• Title/Summary/Keyword: 전력케이블 절연체

Search Result 35, Processing Time 0.025 seconds

The functions & Requirements of the Semi-Conducting layer in the power cable. (전력 케이블에서 반도전층의 역할과 요구 특성)

  • Jung, Yun-Tack;Nam, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.101-105
    • /
    • 2001
  • For high voltage XLPE power cables, semiconducting layers have been applied to prevent discharge at the interface between conductor and insulation, and/or insulation and external shielding layer. The semiconducting layers may be also effective to release electrical stress in the interface. The property of semiconducting layers are significantly related to the quality and reliability of power cables. Generally, these semiconducting layers are formed by extruding, the conductibility of the material is given by the carbon black mixed with base polymer. The life of power cables is depended on the smoothness of the interface between insulation and semiconducting layer. If the smoothness is no good, the life of power cables is shorter because the electrical stress and water tree is increased. The causes of no good smoothness are the void of the interface, the protrusions, the contaminants and impurities of the semiconducting layer. The selection and dispersion of the Carbon Black is the significant factor to determine the life of power cable in the manufacturing of semiconducting compound.

  • PDF

Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE (LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석)

  • Kang, S.H.;Park, Y.G.;Kwon, S.S.;Shin, T.S.;Lim, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.216-221
    • /
    • 1999
  • The correlation between propagation of electrical tree and internal partial discharges is discussed. We use specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope and investigated the characteristics of the partial discharge (PD) pulses accompanying with propagation of electrical tree. In the specimens with needle-shaped void, the tree propagates branch type. The length of the tree has good linear relation with average discharge power of PD pulses. In the specimens without needle-shaped void, the tree grows bush type tree. The correlation between the area of the tree and the average discharge power of PD pulses has linear relation.

  • PDF

Aging Diagnosis of 22.9kV Power Cable Using Attenuation Constant (감쇠 상수를 이용한 22.9kV 전력 케이블의 열화 진단)

  • Lee, Sin-Ho;Lee, Chun-Ku;Park, Jin-Bae;Kwak, Ki-Seok;Jang, Seung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1834-1835
    • /
    • 2011
  • 본 논문에서는 22.9kV급 지중 전력 케이블의 열화에 의한 특성 변화를 분석한다. 케이블이 실제 선로로 포설될 경우 케이블에는 고전압이 흐르게 되고, 이로 인해 열이 발생하게 된다. 이와 같이 발생한 열에 의한 절연체 이상은 케이블 사고로 이어지므로 케이블의 열화 특성 분석은 사고를 미연에 방지하기 위해서 필요하다. 따라서 본 논문에서는 실제 선로에 사용된 후 교체된 케이블의 감쇠 상수를 구하여 열화가 진행된 정도에 따른 감쇠상수의 변화를 분석한다. 이 때, 네트워크분석기의 S-파라미터를 이용하여 감쇠 상수를 구하고, 정상 상태 케이블과 폐 케이블의 감쇠상수를 비교하여 열화에 의한 케이블의 특성을 분석한다.

  • PDF

Estimation of Thermal History in Power Cable Insulation Core Using by DSC Thermal Analysis (DSC를 이용한 전력케이블 절연체 열이력 추정법)

  • Jung, Sun-Young;Choi, A-Leum;Lee, Kyoung-Yong;Kim, Dong-Hun;Kang, Seung-Hun;Park, Keun-Ryong;Kim, Do-Young;Chang, Woo-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1467-1468
    • /
    • 2011
  • 본 논문에서는 전력케이블 절연 코어의 열이력을 추정하기 위해 DSC를 이용한 열 이력 분석을 진행하였다. 일반적으로 전력케이블 절연코어에 인가된 열이력은 온도이력, 시간에 따라 그 열적거동이 달라지며, 이러한 특성을 이용하여, 제조공정 이력 및 운영시 부하온도 추정이 가능하다. 현재까지 보고된 열이력 추정연구는 XLPE절연체에 국한 되어 있으며, 온도 이력과 시간이 열적거동에 미치는 영향 및 반도전층 자재까지 확대하여 적용한 사례는 거의 보고되어 있지 않다. 본 논문에서는 DSC 모의실험을 통한 절연코어 샘플에 대하여, 열이력 추정 분석법의 유효성을 평가할 수 있었다.

  • PDF

AC Breakdown Voltage Characteristics of 22.9kV TR XLPE Power Cable Before and After 14days Cyclic Aging and AWTT (14주기 열화 및 AWTT에 따른 22.9kV TR CNCV-W 전력케이블의 교류파괴전압 특성분석)

  • Kim, We-Young;Heo, Jong-Cheol;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1507-1508
    • /
    • 2006
  • XLPE 절연 전력케이블의 제조과정에서 발생하는 가교부산물을 제거할 목적으로 14주기노화를 실시하며, XLPE 절연체에 발생하는 수트리를 가속 발생 성장시킬 목적으로 가속수트리 열화를 실시한다. 22.9kV 트리억제형(TR CNCV-W) 케이블에 대하여 14주기노화 전과 후, 120, 240, 360일 가속수트리(AWTT) 후의 파괴전압을 분석하였다. 14주기노화는 상승효과와 감소효과가 비슷하게 작용하는 것으로 나타났으며, 240일 AWTT 이후에 노화가 가속되는 것으로 나타났다.

  • PDF

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables (고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2017
  • The demand for electric power is increasing every year. All facilities operating at power stations and all facilities used in transmitting high volumes of electric power are therefore expected to operate with a high degree of reliability. 6.6 kV XLPE 100 SQ 1C cables are used to deliver high levels of generated electric power. Depending on the method of manufacture, installation environment, and usage conditions, the deterioration processes of power cables start from the instant of operation. Cable junctions may break down in three years from the start of operation due to manufacturing or construction defects. We have invented the first device in Korea to monitor the status of live cables and installed these at Korea Western Power Co., Ltd.. We have set the criteria to determine deterioration status and specified the degree of deterioration at which one should replace the cables. In this paper, we present the effect of insulation layer and sheath on the insulation resistance status in cables.

Electric Field Distribution and AC Dielectric Breakdown Properties according to Needle Electrode in EHV Insulators of XLPE (초고압 절연체 XLPE의 침전극에 따른 전계분포와 AC 절연파괴특성)

  • An, Byung-Chul;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.136-139
    • /
    • 2006
  • 최근 전력수요의 급증과 더불어 기기의 소형화와 경랑화를 위해 고분자절연재료의 사용이 증가하였으며, 근래 들어 환경성의 문제가 거론되면서 반영구적인 절연재료의 요구가 급증하였다. 그로 인하여 초고압 케이블의 절연재료로서 가교폴리에틸렌이 사용되어지고 있다. 이에 본 논문에서는 초고압전력용 케이블에서 절연재료로 사용되고 있는 가교폴리에틸렌 (XLPE) 내부전계분포 및 파괴전압과의 상관관계를 알아보기 위해 케이블에 칩 전극을 삽입하여 두께를 0.5, 1, l.5 [mm] 변화시켜 파괴전계를 검출하였으며, 또한 와이블 해석을 통한 파괴전압의 척도파라미터룰 검출하여, 시뮬레이션 인가전압으로 사용하였다. 시뮬레이션 경계요소법 (BEM)을 이용한 3 차원 전계해석 프로그램으로 조사하였다.

  • PDF

DC용 절연지 및 절연 컴파운드의 특성

  • Park, Se-Eun;Yeon, Bok-Hui;Lee, Sang-Jin;Sim, Seong-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.217-218
    • /
    • 2005
  • 절연지는 콘덴서 뿐만 아니라 변압기 및 부싱, 전력 및 전화케이블의 절연을 위해 전기분야에서 폭넓게 사용되고 있다. 각 응용 분야에 따라서는 전기적, 기계적 특성이 달리 요구되므로 절연지의 준비단계나 펄프의 처리단계에서 서로 다른 방법으로 만들어진다. 본 내용은 절연지의 절연파괴 강도와 유전체 손실에 영향을 미치는 것들에 대한 발전된 기술을 소개하기 위한 것이다. 절연지의 전기적 특성을 고찰한다는 것은 절연지가 거의 항상 절연유와 함침된 상태로 사용되기 때문에 매우 어렵다. 왜냐하면 함침에 사용된 절연유의 증류에 따라 조합된 절연유와 절연지의 전기적 특성에 대단히 중요한 영향을 미치기 때문이다. 본 내용에 소개된 결과들은 전기 절연과 관련된 절연지의 주요 물리적 특성을 관찰하기 위하여, OF 케이블에 사용된 한가지 특수한 저점도유를 사용해서 얻은 것이다. 또 본 내용은 절연지의 주요 열적, 기계적 특성과 절연유의 주요 특성이 기술되어 있다.

  • PDF