• Title/Summary/Keyword: 전도파괴

Search Result 156, Processing Time 0.023 seconds

A Study on the Property of the Breakdown Strength and the Electrical Conduction of the PET Flim being Interface (계면이 존재하는 PET flim의 절연파괴와 전기전도특성에 관한 연구)

  • Kang, Moo-Sung;O, Jae-Hyung;Park, Dae-Hee;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.221-223
    • /
    • 1996
  • The test on the breakdown strength and the electrical conduction property about the PET flim have been done when the interface exist and do not exist between the PET flim. The PET flim that does not exist the interface uniformly maintained the breakdown strength as the temperature increase. But, the breakdown strength of the PET flim inserted carbon black flim decreased as the temperature increase. The initial current of the PET flim inserted carbon black flim was higher than the PET flim and the uniformly distributed between 2.2E-9 and 2.5E-9 above 5kV/mm.

  • PDF

Measurement of Dynamic Crack Propagation Velocity in Polymers (고분자 재료의 동적 균열전파속도 측정)

  • 이억섭;한민구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.947-951
    • /
    • 1989
  • It is well-known that the parameters of dynamic fracture mechanics depend not only on dimensions, loading and boundary conditions but also on the dynamic crack propagation velocity. Because the measurement of dynamic crack propagation velocity measuring device which can easily be expanded without modification is proposed in this report. it was found that the experimentally determined dynamic crack propagation velocity agreed well with those from other investigations in some polymers such as PMMA. Homalite-100 and Epoxy.

증착조건 변화에 따른 화학증착 알루미나 휘스커의 성장 및 특성변화

  • Kim, Jun-Gyu;Kim, Hyo-Jun;Choe, Du-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.66-66
    • /
    • 2010
  • 알루미나는 높은 온도에서 열적으로 안정되고 경도가 높으며 내화학, 내마모 특성이 우수하며 또한 강도대비 비중이 낮아 무게를 줄일 수 있다는 장점을 가지고 있다. 이러한 특성으로 인하여 우주항공, 국방, 원자력등 극한의 온도를 견뎌야 하는 고도의 신뢰성이 요구되는 고온구 조물로서 응용이 되고 있다. 특히 알루미나를 휘스커 형태로 만들어 세라믹 복합체에 결합 할 경우 복합체의 기지 내에서 강화재의 역할을 함으로써 취성 파괴를 억제하고 열 전도율 저하등의 이점을 가져올 수 있다. 그리하여 본 연구에서는 알루미나 휘스커를 성장을 위하여 Al-triisoproxide계를 이용하여 화학기상증착법으로 가장 안정된 열적 특성을 가지고 온도의 변화에 따라 상 변화가 일어 나지 않는 알파 알루미나 상을 가지는 알루미나 휘스커를 성장시키기 위한 연구를 하였다. 또한 증착 온도, 압력, 입력기체비등 증착 조건을 변화시켜가면서 알파 알루미나 휘스커의 성장 거동을 살펴 보았다. 증착 조건 변화에 따라 알파 알루미나는 막이 증착되는 부분과 휘스커가 성장되는 부분이 있으며 휘스커의 밀집도와 길이방향, 직경방향 성장등 여러 가지 성장 특성을 달리하였다. 이러한 결과를 바탕으로 증착조건에 따른 알파 알루미나 휘스커 성장영역을 도식화하였다.

  • PDF

Arching Effects on Stability of Translating Rigid Retaining Walls (아칭효과가 평행이동하는 강성옹벽의 안정성에 미치는 영향)

  • 백규호
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.127-136
    • /
    • 2004
  • The soil arching in the backfill, which affects the magnitude and distribution of active earth pressure on a retaining wall, has also an effect on the stability and cross-sectional area of the retaining wall. In this study, results obtained from Paik's equation that includes arching effect on active earth pressure are compared with those from Coulomb theory to investigate the influence of the soil arching on active earth pressure, overturning moment, stability and cross-sectional area of translating rigid retaining walls. The comparisons show that the active forces including arching effects are always higher than those from Coulomb theory, irrespective of $\phi$ and $\delta$ values. The overturning moments, shear force and moment on the rigid wall are also higher when considering arching effects than when not considering arching effects. The deviation of shear forces and moments by including and excluding arching effects becomes maximum at the height of 0.02-0.08 times wall height from the base of the wall. Therefore, if a translating rigid retaining walls is designed based on Coulomb theory, the wall may reach sliding and overturning failures due to arching effect in the backfill and the cross-sectional area of the wall, especially at lower part of the wall, may not be sufficient to resist to shear force and moment.

Comparative Study of Reliability Design Methods by Application to Donghae Harbor Breakwaters. 2. Sliding of Caissons (동해항 방파제를 대상으로 한 신뢰성 설계법의 비교 연구. 2. 케이슨의 활동)

  • Kim, Seung-Woo;Suh, Kyung-Duck;Oh, Young-Min
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.2
    • /
    • pp.137-146
    • /
    • 2006
  • This is the second of a two-part paper which describes comparison of reliability design methods by application to Donghae Harbor Breakwaters. In this paper, Part 2, we deal with sliding of caissons. The failure modes of a vertical breakwater, which consists of a caisson mounted on a rubble mound, include the sliding and overturning of the caisson and the failure of the rubble mound or subsoil, among which most frequently occurs the sliding of the caisson. The traditional deterministic design method for sliding failure of a caisson uses the concept of a safety factor that the resistance should be greater than the load by a certain factor (e.g. 1.2). However, the safety of a structure cannot be quantitatively evaluated by the concept of a safety factor. On the other hand, the reliability design method, for which active research is being performed recently, enables one to quantitatively evaluate the safety of a structure by calculating the probability of failure of the structure. The reliability design method is classified into three categories depending on the level of probabilistic concepts being employed, i.e., Level 1, 2, and 3. In this study, we apply the reliability design methods to the sliding of the caisson of the breakwaters of Donghae Harbor, which was constructed by traditional deterministic design methods to be damaged in 1987. Analyses are made for the breakwaters before the damage and after reinforcement. The probability of failure before the damage is much higher than the allowable value, indicating that the breakwater was under-designed. The probability of failure after reinforcement, however, is close to the allowable value, indicating that the breakwater is no longer in danger. On the other hand, the results of the different reliability design methods are in fairly good agreement, confirming that there is not much difference among different methods.

Precisely Nondestructive Diagnosis and Slope Stability of the Bonghwa Bukjiri Maaeyeoraejwasang (Rock-Carved Seated Buddha Statue), Korea (봉화 북지리마애여래좌상의 비파괴 정밀진단과 사면안정성 분석)

  • Cho, Ji-Hyun;Jo, Young-Hoon;Chun, Yu-Gun;Choi, Joon-Hyun;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.26 no.2
    • /
    • pp.121-132
    • /
    • 2010
  • The Bukjiri Maaeyeoraejwasang (National Treasure No. 201) consists of two-mica granite in medium size, which was the simbol of power in the region of the Silla period. Magnetic susceptibility of the host rock was measured as 0.41(${\times}10^{-3}$ SI unit), which has the similar range with surrounding outcrop. The Buddha developed parallel discontinuous plane of NE to SW strike and damaged seriously by exfoliation, granular disintegration and brown discoloration as 41.5%, 16.7% and 40.0%, respectively. As a result of the ultrasonic velocity, which was relatively weak values as 1,629m/s (Buddha area) and 1,549m/s (surrounding outcrop), improved about 900m/s compared to last treatment. From the results of the evaluation for slope stability, identified the possibility of toppling failure in the Buddha, and planar and wedge failure in host rock. Therefore, we suggest for the safely conservation of the Buddha, continuance monitoring for understand behavior of discontinuity system of the surface, and necessitate foundation reinforcement method for the rock which has the danger of collapse.

Characterization of Structure and Electrical Properties of $TiO_2$Thin Films Deposited by MOCVD (화학기상증착법에 의한$TiO_2$박막의 구조 및 전기적 특성에 관한 연구)

  • Choe, Sang-Jun;Lee, Yong-Ui;Jo, Hae-Seok;Kim, Hyeong-Jun
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.3-11
    • /
    • 1995
  • $(TiO_{2})$ thin films were deposited on p-Si(100) substrate by APMOCVD using titanium isopropoxide as a source material. The deposition mechanism was well explained by the simple boundary layer theory and the apparent activation energy of the chemical reaction controlled process was 18.2kcal /mol. The asdeposited films were polycrystalline anatase phase and were transformed into rutile phase after postannealing. The postannealing time and the film thikness as well as the postannealing temperature also affected the phase transition. The C-V plot exhibited typical charateristics of MOS diode, from which the dielectric constant of about 80 was obtained. The capacitance of the annealed film was decreased but those of the Nb or Sr doped films were not changed. I-V characteristics revealed that the conduction mechanism was hopping conduction. The postannealing and the doping of Nb or Sr cause to decrease the leakage current and to increase the breakdown voltage.

  • PDF

Model Test Study on the Earth Pressure of the Retaining Wall with the Relieving Platform (선반식 옹벽의 토압에 관한 모형시험 연구)

  • Kim, Byoungil;Yoo, Wankyu;Yang, Mirim;Park, Yongseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1C
    • /
    • pp.27-35
    • /
    • 2012
  • The relieving platform has the advantage of decreasing the total lateral earth pressure on the retaining wall and increasing the overall stability of the structure. Several modeling tests were performed to determine the earth pressure distribution on the retaining wall with a relieving platform and to compare it with that of the cantilever retaining wall. Different types of soil and angle of cutting surface were used to determine the effect of the soil characteristics and the backfill conditions on these earth pressure distributions. From the modeling tests, comparisons between the retaining wall with a relieving platform and the cantilever retaining wall show that the reduction of the lateral earth pressure and deformation of wall was indicated clearly on the retaining wall with a relieving platform. And the overall stability was increased by the relieving platform.

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

Horizontal Stress Analysis of Electric Pole using Earth Pressure Cell from Mock-Up Tension Test (전주의 실물인장실험시 토압계를 이용한 수평토압분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.62-69
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. 4 anchor blocks decreased earth pressure at G.L.-0.9[m]. It is considered that 4 anchor blocks installed along 80[cm] vertically are main reason. Overall, when more anchor blocks are constructed, excavation area is large, and constructivity such as backfill is bad, therefore one anchor block would be preferred.