• Title/Summary/Keyword: 전도거리

Search Result 141, Processing Time 0.022 seconds

Numerical Analysis of Horizontal Collector Well in Riverbank Filtration (수평 방사형 집수정 활용 강변여과 취수 수치 분석)

  • Kim, Hyoung-Soo;Jeong, Jae-Hoon
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • Groundwater flow due to intake of horizontal collector well in riverbank filtration site was analyzed by use of numerical groundwater modeling program (FEFLOW 5.1). Drawdowns of groundwater table nearby collector well were evaluated according to variations of several conditions; pumping rate, thickness of aquifer, offset distance from well to shore line of stream, conductance of streambed. It is observed that the drawdowns of groundwater table are clearly changed according to the variations of these conditions. The results of sensitive analysis shows that the thickness of alluvial aquifer and the offset distance are more sensitive than the conductance of streambed in evaluation of drawdown. This result implies that hydrogeological conditions, as like thickness of aquifer and its distribution in the site are important factors in site selection and evaluating the availability of riverbank filtration intake using horizontal collector well system. It is also revealed that numerical modeling using FEFLOW with 1-D discrete element feature can give efficient quantitative evaluation of horizontal collector well and estimation of availability of riverbank filtration site.

Evaluation of stream depletion due to nearby groundwater pumping using Baalousha analytical solution (Baalousha 해석해를 이용한 하천 주변 지하수 양수로 인한 하천수 감소 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il-Moon;Hong, Sung Hun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.2
    • /
    • pp.99-107
    • /
    • 2018
  • This study was to evaluate the stream depletion due to groundwater pumping from 17 wells near the Anseongcheon upper stream using the Baalousha's analytical solution (2012) which directly considers stream width and streambed hydraulic conductivity. The input hydraulic values of aquifer and streambed were obtained from the pumping tests and seepage experiments. The estimated streamflow depletion rates divided by pumping rate (dimensionless stream depletion) showed a range from 0.23 to 0.89 for 5 year pumping. In particular, the results revealed that the groundwater pumping has insignificant effects on streamflow when the stream depletion factor (SDF) is higher than 1,000 with values of dimensionless stream depletion lower than 0.4. A more simple Hunt's solution (1999) also applied to the same wells, and the results showed that the difference between the dimensionless stream depletions calculated by using both solutions could be negligible. From the comparison of the Baalousha's solution (2012) with the Hunt's solution (1999) with total 3,000 cases of simulations with combinations of various aquifer and stream properties, the stream-well distance should be more longer than stream width for reducing the discrepancy between both solutions.

Preliminary Shielding Analysis of the Concrete Cask for Spent Nuclear Fuel Under Dry Storage Conditions (건식저장조건의 사용후핵연료 콘크리트 저장용기 예비 방사선 차폐 평가)

  • Kim, Tae-Man;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.391-402
    • /
    • 2017
  • The Korea Radioactive Waste Agency (KORAD) has developed a concrete cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. During long-term storage of spent nuclear fuel in concrete casks kept in dry conditions, the integrity of the concrete cask and spent nuclear fuel must be maintained. In addition, the radiation dose rate must not exceed the storage facility's design standards. A suitable shielding design for radiation protection must be in place for the dry storage facilities of spent nuclear fuel under normal and accident conditions. Evaluation results show that the appropriate distance to the annual dose rate of 0.25 mSv for ordinary citizens is approximately 230 m. For a $2{\times}10$ arrangement within storage facilities, rollover accidents are assumed to have occurred while transferring one additional storage cask, with the bottom of the cask facing the controlled area boundary. The dose rates of 12.81 and 1.28 mSv were calculated at 100 m and 230 m from the outermost cask in the $2{\times}10$ arrangement. Therefore, a spent nuclear fuel concrete cask and storage facilities maintain radiological safety if the distance to the appropriately assessed controlled area boundary is ensured. In the future, the results of this study will be useful for the design and operation of nuclear power plant on-site storage or intermediate storage facilities based on the spent fuel management strategy.

Nonhomogeneity of the Electrical Properties with Deposition Position in an ITO Thin Film Deposited under a Given R.F. Magnetron Sputtering Condition (동일 증착 조건의 스퍼터링에 의해서 제작된 Indium Tin 산화물 박막의 증착위치에 따른 전기적 특성의 불균질성)

  • 유동주;최시경
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.11
    • /
    • pp.973-979
    • /
    • 2001
  • Tin-doped indium oxide (ITO) thin films were deposited using r.f. magnetron reactive sputtering and the electrical properties, such as the resistivity, carrier concentration and mobility, were investigated as a function of the sample position under a given magnetron sputtering condition. The nonhomogeneity of the electrical properties with the sample position was observed under a given magnetron sputtering condition. The resistivity of ITO thin film on the substrate which corresponded to the center of the target had a minimum value, 2∼4$\times$10$\^$-4/$\Omega$$.$cm, and it increased symmetrically when the substrate deviated from the center. The density measurement result also showed that ITO thin film deposited at the center has a maximum density of 7.0g/cm$^3$, which was a relative density of about 97%, and the density decreased symmetrically as the substrate deviated from the center. The nonhomogeneity of electrical properties with the deposition position could be explained with the incidence angle of the source beam alpha, which is related with an atomic self-shadowing effect. It was confirmed experimentally that the density in film affect both the carrier mobility and the conductivity. In the case where the density of ITO thin film is 7.0g/cm$^3$, the magnitude of the mean free path was identical with that of the grain size(the diameter of column). However, in the other cases, the mean free path was smaller than the grain size. These results showed that the scattering of the free electrons at the grain boundary is the major factor for the electrical conduction in ITO thin films having a high density, and there exists other scattering sources such as vacancies, holes, or pores in ITO thin films having a low density.ing a low density.

  • PDF

A Study on Evaluation of Slope Stability and Range of Rockfall Hazard of Daljeon-ri Columnar Joint in Pohang, Korea (천연기념물 제415호 포항 달전리 주상절리의 사면안정성 평가 및 낙석 위험 범위 설정)

  • Kim, Jae Hwan;Kang, Mu Hwan;Kong, Dal-Yong;Jwa, Yong-Joo
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.505-515
    • /
    • 2021
  • In this study, we evaluated the slope stability of the Pohang Daljeon-ri columnar joint (Natural Monuments # 415) and calculated the maximum energy, jumping height and moving distance of rockfalls using a simulation. Based on the results, we established the range of rockfall risk. The slopes of the Pohang Daljeon-ri columnar joint have dip directions of 93.79°, 131.99°, 165.54° and 259.84° from left (SW) to right (NE). Furthermore, they have a fan-like shape. The Pohang Daljeon-ri columnar joints are divided into four sections depending on the dip direction. The measurement results of the discontinuous face show that zone 1 is 125, zone 2 is 261, zone 3 is 262, zone 4 is 43. The results of slope stability analyses for each section using a stereographic projection method correspond to the range of planar and toppling failure. Although it is difficult to diagnose the type of failure, risk evaluation of currently falling rocks requires further focus. The maximum movement distance of a rockfall in the simulation was approximately 66 m and the rockfall risk range was the entire area under slope. In addition, it is difficult to forecast where a rock will fall as it rolls in various directions due to topographic factors. Thus, the installation of measures to prevent falling is suggested to secure the stability based on the results of the rockfall simulations and its probabilistic analysis.

Evaluation of Effects of Groundwater Pumping Near Stream Using Analytical Model (해석적 모형에 의한 하천변 지하수 양수 영향 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won;Lee, Min Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.617-625
    • /
    • 2016
  • The objective of this study was to evaluate the groundwater drawdown and streamflow depletion due to each groundwater pumping from 110 wells located near stream using the Hunt's analytical solution (1999). The calculated results revealed that the streamflow depletion rate divided by the pumping rate for each well location mostly exceeded about 80% of pumping rate on average for 5 years. The results also showed that the stream boundary condition has made the influence distance shorter and the drawdown distribution skewed except for the streambed hydraulic conductivity and the stream bed factor (SBF) lower than $1.0{\times}10^{-9}m/s$ and 1.0, respectively. It was found that the groundwater pumping has significant impacts on the stream depletion showing above 80 % of stream depletion rate when the streambed hydraulic conductivity is higher than $1.0{\times}10^{-7}m/s$ and the stream depletion factor(SDF) is lower than 100. However, for other conditions, the SDF is not sufficient to be used as a criterion for determining whether the pumping has great impacts on stream depletion or not. Furthermore, the variation of the streambed hydraulic conductance has little change in stream depletion rate for the condition that the stream width is greater than 400 m.

Study on Wet chemical Etching Characterization of Zinc Oxide Film for Transparency Conductive Oxide Application (투명 전도성 산화물 전극으로의 응용을 위한 산화아연(ZnO) 코팅막의 습식 식각 특성연구)

  • Yoo, Dong-Geun;Kim, Myoung-Hwa;Jeong, Seong-Hun;Boo, Jin-Hyo
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • In order to apply for transparent conductive oxide(TCO), we deposited ZnO thin films on the glass at room temperature by RF magnetron sputtering method. Deposition conditions for high transmittance and low resistivity were optimized in our previous studies. Under the deposition condition with the RF power of 200 W, target to substrate distance of 30 mm and working pressure of 5 mTorr, highly conductive($7.4{\times}10^{-3}{\Omega}cm$) and transparent(over 85%) ZnO films were prepared. Highly oriented ZnO film in the [002] direction were obtained with specifically designed ZnO targets. Systematic study on dependence of deposition parameters on electrical and optical properties of the as-grown ZnO films were mainly investigated in this work. And for application tests using these films as transparent conductive oxide anodes, wet chemical etching behaviors of ZnO films were also investigated using various chemicals. Wet-chemical etching behavior of ZnO films were investigated using various acid solutions. The concentrations of these different acid solutions were controlled to study the etching shapes and etching rate. ZnO films were anisotropically etched at various concentrations and wet etching led to crater-like surface structure. Also we firstly found that the etching rate and etching shapes of ZnO films strongly depended on the etchant concentrations (i.e. pH) and the etching rate is exponentially decreased with increasing pH values regardless of the acid etchants.

Wide Bandgap 박막 태양전지 제작을 위한 P-type a-$SiO_x$:H layer 최적화에 관한 연구

  • Yun, Gi-Chan;Kim, Yeong-Guk;Park, Seung-Man;Park, Jin-Ju;Lee, Seon-Hwa;An, Si-Hyeon;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.153-153
    • /
    • 2010
  • p-i-n 형 비정질 실리콘 박막 태양전지에서 p층은 창물질(window material)로서 전기 전도도가 크고, 빛 흡수가 적어야한다. p층의 두께가 얇으면 p층 전체가 depletion layer가 되고 충분한 diffusion potential을 얻을 수 없어 open-circuit voltage ($V_{oc}$)가 작아진다. 반대로 p층 두께가 두꺼워지면 빛 흡수가 증가하고, 표면 재결합이 문제가 되어 변환효율이 감소한다. 밴드갭이 큰 물질로 창층을 제작하게 되면 보다 짧은 파장의 입사광이 직접 i층을 비추므로 Short-circuit current ($I_{sc}$) 와 fill factor를 증가시킬 수 있다. 하여 본 연구에서는 기존의 창층으로 사용되는 Boron을 doping한 p-type a-Si:H 대신에 $N_2O$를 첨가한 p-type a-$SiO_x$:H의 $N_2O$ flow rate에 따른 밴드갭의 변화에 관한 연구를 수행하였다. p-type a-$SiO_x$:H Layer는 $SiH_4$, $H_2$, $N_2O$, $B_2H_6$ 가스를 혼합하여 증착하게 되는데 $SiH_4$, 가스와 $H_2$ 가스의 혼합비는 1:20, $B_2H_6$ 농도는 0.5%로 고정 하였으며 $N_2O$의 flow rate을 가변하며 증착하였다. $N_2O$의 가변조건은 5에서 50sccm으로 가변하여 증착하며 일반적으로 사용되는 RF-PECVD (13.56MHz)를 이용하였고 증착 온도는 175도, 전극간의 거리는 40mm, 파워와 압력은 30W, 700mTorr로 고정하여 진행하였다. 전기적 특성을 알아보기 위해 eagle 2000 Glass를 사용하였고 구조적 특성은 p-type wafer를 사용하여 각각 대략 200nm의 두께로 증착하였다. 증착 두께는 Ellipsometry를 이용하였으며 전기 전도도는 Agilent사의 4156c를 구조적특성은 FT-IR을 사용하여 측정하였다. Conductivity(${\sigma}_d$)는 $N_2O$가 증가함에 따라 $8.73\;{\times}\;10^{-6}$에서 $5.06\;{\times}\;10^{-7}$으로 감소하였고 optical bandgap ($E_{opt}$)은 1.71eV에서 2.0eV로 증가함을 알 수 있었다. 또한 reflective index(n)의 경우는 4.32에서 3.52로 감소함을 나타내었다. 기존의 p-type a-Si:H에 비해 상당한 $E_{opt}$을 가지므로 빛 흡수에 의한 손실을 줄임으로서 $V_oc$를 향상 시킬 수 있으며 동시에 짧은 파장에서의 입사광이 직접 i층을 비추므로 $I_{sc}$와 FF를 향상 시킬 수 있으리라 예상된다. 다소 낮은 전도도만 개선한다면 고효율의 박막 태양전지를 제작 할 수 있을 것으로 기대된다.

  • PDF

Development of Automatic System to Measure Transmitted Ultrasonic Speed of Raw Ginseng (수삼의 초음파 전달속도 계측 자동화 시스템 개발)

  • 서동현;김기대;강호양;김찬수;이현동
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.592-599
    • /
    • 2002
  • 본 연구에서는 수삼의 가공전 선별을 위해 현장에서 편리하게 사용할 수 있는 초음파 전달 속도 계측 자동화 시스템을 개발하여 그 성능을 평가하고자 하였으며 결과를 요약하면 다음과 같다. 1. 개발된 시스템은 제어용 컴퓨터, 시스템 구동 및 탐촉자 이동 장치, 하중 변환장치, 초음파 발생 및 송수신 장치 등으로 구성되었다. 2. 제어 및 계측용 프로그램은 압축력, 측정 대상물의 크기, 초음파 전달 시간을 순차적으로 계측하여 초음파 전달 속도를 계산하는 알고리즘을 개발하였으며, Visual Basic 6.0으로 작성되었다. 모터의 작동, A/D 변환, RS232C 통신 등과 관련된 부분은 각각의 모듈화된 함수로서 구동하고자 하였다. 3. 개발된 시스템의 속도와 거리별 이동 거리별 오차를 측정한 결과 0∼0.04mm 범위를 나타내었다. 이 값은 시스템의 허용오차인 0.17mm 오차보다는 현저히 작은 값이었고 15mm/s와 30mm/s의 이동 속도에서 모두 비슷한 크기의 오차값을 나타내었다. 4. 개발된 시스템의 속도별 반복정밀도 실험 결과 측정위치에서의 반복에 의한 정지 위치 오차는 전 구간에서 0.02mm 이내로 나타났고, 이동 평판의 이동속도가 15mm/s였을 경우에는 이동 회수 30회, 이동 거리 60mm일 때 최대 편차 0.019mm를 나타냈으며 이동속도가 30mm/s일 경우에는 이동 회수 40회, 이동거리 20mm에서 0.02mm의 최대 편차를 나타내었다. 5. 5개의 알루미늄 조각의 크기를 시스템으로 측정한 결과 측정값의 최대 편차는 0.08mm였다. 이 값은 시스템의 허용오차인 0.17mm의 50% 수준으로 시스템은 대상물의 크기 측정에 적당하다고 사료되었다. 6. 절단된 수삼의 초음파 전달속도는 평균 396.4m/s였다.를 축열재로 사용할 경우 재생기를 반으로 나누어서 가열부 쪽에 철선을, 냉각부 쪽에 철망을 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차는 높게 나타났고, 재생기 양단의 압력 차는 낮게 나타났다. 재생기 축열재로서 철망-철선을 사용할 경우 철선-철망 ø1.2-150이 전열 표면적은 작으나 재생기 양단의 온도차가 가장 큰 것으로 나타났으며 재생기 양단의 압력 차는 가장 낮게 나타나 공시 철망- 철선 혼합 축열재중 가장 우수함을 알 수 있다. 4. 철망사이에 철선을 삽입한 축열재의 경우, 철망사이에 삽입한 철선의 직경이 큰 것이 철선의 직경이 작은 것보다 재생기의 양단의 온도차가 높게 나타났고 재생기 양단의 압력차는 작게 나타났다. 그러므로 철망사이에 철선을 삽입한 것 중 성능이 우수한 것은 150-ø2. 0-150으로 나타났다. 5. 실험한 재생기 축열재들 중에서 성능이 우수한 것들을 비교한 결과, 복합 철선 ø1.2-1 50이 가장 성능이 좋은 것으로 나타났다.적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수

  • PDF

A Study on the Electrical and Physical Properties of Cement Mortar used Carbon Material Industrial by-product (탄소소재 산업부산물을 사용한 시멘트 모르타르의 전기·물리적 특성 연구)

  • Jo, Jeong-Hoon;Kim, Nam-Il;Lee, Young-Jun;Seo, Sung-Kwan;Chu, Yong-Sik
    • Resources Recycling
    • /
    • v.30 no.6
    • /
    • pp.19-27
    • /
    • 2021
  • Electrically conductive mortar used in industrial carbon material byproducts was manufactured and analyzed in this study. The contents of the carbon material and mixed water were controlled, and the distance between electrodes was set to 0.42 m and 0.88 m. The carbon material was graphite with a layered structure. The carbon material was used as fine powder and aggregate substitutes according to particle size. The average particle sizes of each materials were 18.4㎛ and 546.1 ㎛ and the electrical conductivities were 62.3 S/m and 32.5 S/m, respectively. To maintain similar mortar flow in each sample, the water content was increased with increasing carbon material, and accordingly, the porosity showed an increasing trend. When electrode distance of the mortar (week 6) was 0.42 m, the voltage-current values were 342 V-1.48 A (S20) and 349 V-1.44 A (S30). For electrode distance of 0.88 m, these values were 513 V-0.98 A (S20) and 500 V-1.01 A (S30). The exothermic properties improved with increasing carbon material content and decreasing electrode distance.