• Title/Summary/Keyword: 전단 패널

Search Result 90, Processing Time 0.027 seconds

The Shear Capacity of CFT Column to H-Beam End plate Connections with Penetrated High-Strength Bolts (관통형 고력볼트를 사용한 엔드플레이트형식 CFT 기둥-H형강 보 접합부의 전단성능)

  • Kim, Young Ju;Kim, Jae Keon;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.351-362
    • /
    • 2000
  • This paper is to study on the behavior of CFT column to H-beam end plate connections with penetrated high-strength bolts under cyclic load. The main parameters are as follows: 1) the thickness of end plate: 16mm, 22mm and 25mm, 2) the thickness of column : 9mm and 12mm. Comparison and analysis on the test results are performed in accordance with parameters. This study investigates energy absorption capacity of beam-column connections and analyzes the shear strength of joint panel. The shear strength of joint panel is estimated by superimposing the strength of the steel which is based on the von Mises yield criterion and that of the concrete which is used the Strut model to consider the effect of filled concrete.

  • PDF

Characteristics of Sandwich Panels and Indoor Composite Materials (샌드위치 패널 및 내장재 특성 연구)

  • 허완수;이상원;김장엽;이종호
    • Composites Research
    • /
    • v.14 no.6
    • /
    • pp.1-8
    • /
    • 2001
  • In this paper, the sandwich panel composites consisting of core material and face sheet were studied to evaluate the mechanical properties, noise level and fire resistance including flammability, smoke, and toxicity. Four types of sandwich panel were prepared using various kinds of panel and honeycomb materials. It was observed that Al honeycomb/Al skin composite materials had the excellent flatwise tensile strength and edgewise compressive strength compared with other types of composites. The flatwise compressive strength and flexural strength of Nomex honeycomb/Al skin composite were higher than those of other composites. PMI form/Al skin composite showed the higher core shear strength and facing bending strength. From the experimental results of flame resistance tests, it can be said that the phenol based skin composite has the excellent flame retardation properties, which are similar to those of the commercial skin composites.

  • PDF

Concrete-Panel Retaining Wall anti-crack sleeve inserted (균열방지 슬리브가 매설된 패널식 옹벽)

  • Jang, Sung-Ho;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.345-349
    • /
    • 2019
  • In Korea, the mountainous area occupies more than 70% of the whole country, cutting of earth slope that cuts a part of the ground surface is widely used when building infrastructures such as road, railroad, and industrial complex construction. In recent years, regulations on environmental damage have become more strict, and various methods have been developed and applied. Among them, Concrete-Panel Retaining Wall technique is actively applied. Concrete-Panel Retaining Wall is a method to resist horizontal earth pressure by forming a wall by attaching a precast retaining wall to the front of the support material and increasing the shear strength of the disk through reinforcement of the support material. Soil nailing, earth bolt, and ground anchor are used as support material. Among them, ground anchor is a more aggressive reinforcement type that introduces tensile load in advance to the steel wire, and a large concentrated load acts on the front panel. This concentrated load is a factor that creates cracks in the concrete panel and reduces the durability of the retaining wall itself. In this study, steel pipe sleeves and reinforcements were purchased at the anchorage of the panel to prevent cracks, and by applying bumpy shear keys to the end of the panel, the weakness of the individual behavior of the existing grout anchors was improved. The problem of degraded landscape by exposure to front concrete of retaining wall and protrusion of anchorage was solved by the production of natural stone patterns and the construction of sections that do not protrude the anchorage. In order to verify the effectiveness of anti-crack sleeves and reinforcements used in the null, indoor testing and three-dimensional numerical analysis have been performed, and the use of steel pipe sleeves and reinforcements has demonstrated the overall strength increase and crack suppression effect of panels.

Shear Strength of Vertical Joints in Precast Concrete Panel with Shear Key (전단키를 갖는 프리캐스트 콘크리트 패널 수직접합부의 전단강도)

  • Lee, Sang-Sup;Park, Keum-Sung;Bae, Kyu-Woong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.151-158
    • /
    • 2019
  • A concrete core is used widely as lateral stability systems in high-rise modular buildings. As an alternative to traditional cast in-situ core, the precast concrete(PC) method can accelerate the construction of reinforced concrete cores. A core composed of precast elements differs from a in-situ core in having connections between the precast elements. The typical vertical connection between PC panels is consisted of shear keys, loop bars, lacer bars and grout. In this study, the effect of vertical connection components on shear strength is investigated experimentally. The test results show that the contribution to the shear strength is greater in order of grout strength, shear keys, lacer bars and loop bars. In addition, the numerical models to estimate the shear strength according to two crack patterns in the vertical joint of the PC panels are derived. The feasibility of the numerical models is evaluated by comparing the estimated shear strength and the test results.

Limiting Height Evaluation for Cold-Formed Steel Wall Panels (냉간성형강재 벽체 패널의 한계높이 산정)

  • Lee, Young ki;Miller, Thomas H.
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • This study aimed to develop experiment-based limiting heights for interior, nonload-bearing, cold-formed steelwall panels sheathed with gypsum board and subjected to uniformly distributed lateral loadings. Th e limiting heightswere evaluated by their strength (for flexure, shear, and web crippling) and deflection. Limiting heights for deflectionlimits of L/360, L/240, and L/120 (where L is the height of the wall) were developed over the range of typical designpressures.

Approximate Analysis of Elastic Story Drift of Steel MRFs including Effects of Panel Zone Flexibility (패널존 변형을 포함한 철골모멘트골조의 탄성층간변위 근사해석)

  • Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.105-113
    • /
    • 1996
  • 본 연구에서는 철골모멘트골조의 패널존변형을 명시적으로 고려한 탄성층 간변위의 근사해석 방법을 제안하였다. 본 방법은 고전적 포탈법의 가정 및 D 치법에 기반한 해석적 접근법이다. 즉 포탈법의 가정에 따라 횡력을 받는 골조를 보-기둥 부분 골조로 분해한 후 대표적 내부 부분골조의 보, 기둥 및 패널존에서 기인하는 모든 횡변위 성분을 해석적으로 계산한다. 이때에 필요한 모든 내력(가령 패널존 전단변형 산정을 위한 보의 불균형모멘트)의 결정에 D 치법을 이용한다. 구조바닥의 강막작용을 고려하면 위의 과정을 통하여 산출된 대표적 내부 부분골조의 횡변위는 전체 골조의 횡변위와 거의 동일할 것으로 기대할 수 있다. 본 방법의 타당성 여부는 반강절 접합요소를 사용한 해석적 엄밀해와 비교하여 검증하였으며 만족스런 결과를 주는 것을 확인하였다. 본 연구의 방법에 의해 컴퓨터해석에 의하지 않고도 철골모멘트골조의 탄성층간변위를 실용성있는 정확도로서 신속하게 산정할 수 있으므로 본 연구의 결과는 예비적 횡강성 평가에 유용하게 사용될 수 있다. 또한 본 방법의 적용과정에서 해석자는 철골모멘트골조의 횡변위 기동에 관한 물리적 감각을 증진시킬 수 있을 것으로 사료된다.

  • PDF

Determination of Efficient Shear Stud Spacing in Steel-Concrete Panel(SCP) considering Local Buckling Behavior (국부좌굴 현상을 고려한 강판 콘크리트 패널의 효율적인 스터드 배치 간격 설정)

  • Kim, JoungRae;Lee, WonHo;Kwak, Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.479-484
    • /
    • 2017
  • In this paper, finite element analysis of Steel-Concrete panel(SCP) was conducted considering the local buckling behavior and the optimized design of shear studs arrangement was studied by comparing with design guidelines. If the spacing of the studs of SCP is widened, it is easy to be manufactured and the weight fo members become lighter. On the other hand, the steel plate would be vulnerable to the local buckling behavior. Therefore, the guidance and design of SCP limit the maximum spacing of the studs to prevent the development of shear cracks and local buckling, however this is based on the design criteria of the other composite structures. Parameter studies with changes in stud spacing on steel plate and SCP are conducted and the obtained result was compared with values given in design guidelines.

An Experimental Study on Shear Strength of RCS System Beam-Column Jointswith Various Transverse Beam Sections (직교보 단면크기 변화에 따른 RCS구조 보-기둥 접합부의 전단내력에 관한 실험적 연구)

  • An, Jae-Hyeok;Park, Cheon-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.197-204
    • /
    • 2006
  • Recently, in order to realization of construction and economical saving, various studies are progressing. Also, the study on RCS system which is consisted of reinforced concrete column and steel beam is progressing actively. Actually, however, resisting mechanism of panel zone is influenced by transverse beams when the stress transfers inner panel to outer panel but existing literature didn't reflect the effect of transverse beams. This paper is to analyze the test result of five inner beam-column joints specimen with a variable such as web, flange thickness of transverse beam and face bearing plate(FBP) for RCS systems were tested under cyclic loadings conforming to NEHRP recommendation to investigate the effect of transverse beams and the structural performance of beam-column joints. From the test result, it was shown that transverse beams are effective to enhance the shear strength and structural performance of beam-column joints.

Analytical Study of Shear Capacity of Trapezoidal Corrugated Web Girders (건축물 적용을 위한 제형 절곡 웨브 보의 전단성능에 관한 해석적 연구)

  • Lee, Seo Haeng;Park, Geun Woo;Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.1
    • /
    • pp.49-58
    • /
    • 2018
  • This study conducted nonlinear finite element analysis to figure out the influence of shear performance on the ${\beta}$ of girders with trapezoidal corrugated web. Through the experiment specimen, analysis model which is highly accurate was verified. Based on this, a parameter analysis was conducted on key variables affecting ${\beta}$. Proposed formulas of previous studies were analyzed using parameter analysis result. Eurocode was designed to be safer than other proposals. Only models that are included in the inelastic area, depending on the Moon's proposal, were satisfied the proposed formulas by Kim to enhance economic design.

Evaluation of Punching Shear Safety of a Two-Way Void Plywood Slab System with Form (거푸집 패널이 부착된 2방향 중공슬래브의 뚫림 전단 안전성 평가)

  • Hur, Moo-Won;Woo, Hyung-Sik;Park, Jung-Min;Kang, Hyun-Wook;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.182-189
    • /
    • 2021
  • VPS(Void Plywood Slab System, VPS) has optimized the shape of the hollow material. In addition, it has a function to prevent the floating of the hollow material and the separation due to the working load. In this study, the punching shear capacity of flat plate was performed using Void Plywood Slab System with form work panel proposed in the previous study. As a result of the test, the strength of the VSPS specimen in which the hollow material was placed beyond 2.0 times the column width from the loading point was reduced by 9.4% compared to the reference specimen. However, the strength value was about 1.57 times higher than the design value suggested by KBC 2016. It was found that there was no change in stiffness compared to the reference specimen until shear failure occurred in the VSPS specimen in which the hollow material was placed. It can be seen that this experiment is being destroyed by shear as the flexural reinforcing bars are sufficiently reinforced.