Behavioral Characteristics of Precast Concrete Slab using Wheel Load Tester (윤하중 시험 차량을 활용한 프리캐스트 콘크리트 바닥판의 거동 특성)

  • Park, Seok-Soon;Kim, Nak-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • The main objective of this research is to present the behaviors of precast concrete slab under moving wheel loads. The simulated moving wheel tester and precast concrete slab were designed for this research. In particular, a comparative analysis between the structural analysis and the moving wheel load test was evaluated in connection parts, deformation, bedding layer of concrete slab panels. In the comparisons of the test results from static and moving wheel loads, the maximum deformations were similar. It should be noted that the deformation of panel 2 from the static loading test was larger than that of other panels, while the deformations of panels 1 and 3 were more noticeable than that of panel 2.

Prediction of Nonlinear Shear Behavior of Reinforced Concrete Beam-Column Joints (철근콘크리트 보-기둥 접합부의 비선형 전단거동예측)

  • Cho, Chang-Geun;Woo, Sung-Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.29-36
    • /
    • 2009
  • The present study emphasizes a nonlinear model to predict the shear behaviour of reinforced concrete interior beam-column joints. To model the shear behaviour of a panel zone in the beam-column joint, a modified softened truss model theory for in-plane shear prediction was introduced. This relationship was changed to define the characteristics for the rotational spring to represent the shear deformation in the joint by an equivalent moment-rotation relationship from the joint equilibrium. The analysis model was compared with experiments on reinforced concrete interior beam-column joints that were subjected to axial and shear forces, and the current model was found to accurately predict not only the shear force but also the shear deformation in the joint.

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Undamped Forced Vibration Response of Curved Composite Panels using Enhanced Assumed Strain Finite Element-Direct Integration Method (추가변형률 유한요소-직접적분법을 이용한 복합적층 곡선패널의 비감쇠 강제진동응답)

  • Park, Won-Tae;Chun, Kyoung-Sik;Son, Byung-Jik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.247-258
    • /
    • 2004
  • The composite shell element is developed for the solution of undamped forced vibration problem of composite curved panels. The finite element used in the current study is an 4-node enhanced assumed shell element with six degrees of freedom per node. The composite shell element is free of both shear and membrane locking phenomenon by using the enhanced assumed strain(EAS) method. A modification to the first-order shear deformation shell theory is proposed, which results in parabolic thorough-thickness distribution of the transverse shear strains and stresses. It eliminates the need for shear correction factors in the first order theory. Newmark's direct integration technique is used for carrying out the integration of the equation motion, to obtain the repones history. Parametric studies of curved composite panels are carried out for forced vibration analysis by geometrical shapes and by laminated composite; such as fiber orientation, stacking sequence.

Nonlinear Dynamic Behavior of a Cold-Formed Steel Shear Panel by Shaketable Tests (진동대 실험을 통한 조립식 스틸 전단 패널의 비선형 동적 거동)

  • Kim, Tae-Wan;Lee, Moon-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.6 s.46
    • /
    • pp.31-39
    • /
    • 2005
  • The purpose of this study was to investigate the nonlinear behavior of a cold-formed steel (CFS) shear panel, which was composed of built-up columns and tension-only diagonal straps for bracing, when excited by earthquake motions. For the purpose, shaketable tests of a full-scale two-story cold-formed steel (CFS) shear panel were conducted. in the shear panel, the diagonal strap is a major lateral force resisting system, which is a very ductile member, and the columns, which are gravity resisting members, are fabricated by wooing studs, which can't develop their full flexural strength because they may buckle locally. The test results showed that the straps dissipate most of energy of the shear panel in a tension-only and pinched way and the columns dissipate it relatively smaller than the straps but they still contribute to overall dissipation. As a result of this study, investigating real nonlinear behavior of a structure in earthquakes is a very important process by shaketable tests even though it is simple.

Effects of Haunch Reinforced Steel Moment Connection on Elastic Lateral Drift (헌치로 보강된 철골 모멘트 접합부의 탄성 횡변위에 대한 영향)

  • Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.149-157
    • /
    • 1997
  • 철골 모멘트 접합부를 헌치로서 보강할 경우 내진거동이 크게 증진됨이 최근의 실물대 시험에서 입증되고 있다. 본 연구에서는 헌치로서 보강된 철골 모멘트 접합부가 골조의 탄성 횡변위 거동에 미치는 영향을 해석적으로 평가하는 방안을 제시하였다. 즉 내부의 보-기둥 부분골조를 대상으로 기둥, 보 및 이중패널존에서 기인하는 탄성 횡변위 성분을 해석적으로 유도하였다. 핵심이 되는 내용은 헌치 보강시 생성되는 이중패널존의 전단변형을 고려하는 것이었다. 제시된 방안에 의한 예측치는 3차원 유한요소해석에 의한 결과와 잘 부합하였다. 본 연구에서 수행한 사례연구에 의할 때 헌치의 도입으로 패널존의 강성증대가 가장 현저하여서 패널존의 전단변형에서 기인하는 탄성 횡변위가 50%정도 감소되었다. 본 연구의 결과는 아직 잘 알려지지 않은 헌치 보강에 따른 부차효과(side effects)의 이해에 도움이 될 수 있을 것이다.

  • PDF

hysteretic behaviour of exterior HSC column-steel beam joints (고강도 콘크리트 기둥-강재 보 외부 접합부의 이력거동)

  • 조순호;선성규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.3
    • /
    • pp.23-34
    • /
    • 2000
  • 반복하중을 지지하는 4개의 2/3 크리 접합부 실험을 통하여 콘크리트 기둥 및 강재 보로 구성된 골조에 대한 외부 모멘트 접합부의 이력거동을 조사하였다. 주요 실험 변수는 접합부에 배치된 후프근의 수, 콘크리트만의 전단강도 발현응ㄹ 유도한 접합부 상세, 강재 보 플랜지 상, 하부에 스터드 형태의 전단키를 사용한 상세 등이다. 실험 시 관측된 균열양상, 파괴형상 및 다양한 계측결과에 근거하여 접합부 상세에 따른 각 시험체의 거동이 자세히 기술되었으며, 항복 후 보유강도, 강성저하 정도 및 에너지 소산능력 등이 분석되었다. 실험결과에 의하면, 이들 중 패널 및 인접 기둥 영역에 각각 2개의 후프근을 갖는 시험체 (CF3) 가 가장 우수한 이력응답을 나타냈으며, 이러한 형태의 접합부 상헤는 우리나와 같은 약진 지역에 적합할 것으로 판단되었다.

  • PDF

Evaluation on Transverse Load Performance of Lightweight Composite Panels (경량 복합패널의 분포압 강도 성능 평가)

  • Kang, Su-Min;Hwang, Moon-Young;Kim, Sung-Tae;Cho, Young-Jun;Lee, Byung-yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.146-157
    • /
    • 2018
  • Over the last 10 years, the number of disasters has been increasing in Korea. As a result, the need for temporary residences or shelters for disaster conditions is increasing. In this study, post-disaster refugees housing was developed using lightweight composite panels that are lighter than the materials that make up the existing shelter. To accomplish this, the structural performance of the lightweight composite panel was validated. Among the performance tests on the panels, the transverse load test was conducted according to the ASTM E 72 criteria. As a result of the experiment, when each specimen was subjected to a uniformly distributed load, the allowable load was determined according to the span. All the experiments were ended due to a loss of adhesive at the junction of the skin and core. Further analysis was conducted to calculate the shear stress when the junction was dropped. The mean shear stress at the adhesive surface of a specimen, 150 mm and 200 mm in thickness, was 0.0170MPa and 0.0156MPa, respectively. This suggests that similar values were obtained from panels of equal thickness. In addition, this stress provides a criterion of judgment that could be used to inspect the structural performance of the panels. The performance of the panel was evaluated based on the allowable load, but it may be possible to increase the strength of the lightweight composite panel by improving the joining method to avoid separation from the junction.

Predicting the Nonlinear Behavior of Reinforced Concrete Membrane Elements Subjected to Reversed Cyclic Loading (반복하중을 받는 철근콘크리트 막요소의 비선형거동에 대한 예측)

  • 이정윤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.7-13
    • /
    • 2002
  • The behaviors of the reinforced concrete membrane elements are expected by Navier's three principles of the mechanics of materials. The adopted cyclic stress-strain curves of concrete consist of seven different unloading and loading stages in the compressive zone and six other stages in the tensile zone. The curves took into account the softening of concrete that was influenced by the tensile strain in the perpendicular direction of cracks. The stress-strain relationships for steel bar embedded in concrete subjected to reversed cyclic forces considered the tension stiffening effect and Baushinger effect. The predicted results of the analysis based on Navier's principles were in good agreement with the observed shear stress-strain relationships as well as transverse and longitudinal strains.

Development of Device to Resist Horizontal Displacement of Asphalt Concrete Track (아스팔트콘크리트 궤도용 궤도변위 저항 장치 개발)

  • Lee, Seonghyeok;Yoon, Wooyong;Bae, Younghoon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.744-754
    • /
    • 2016
  • Asphalt concrete track (ACT) is a track system connecting wide sleepers and concrete panels on top of an asphalt concrete layer; such a system requires adequate resistance force against various longitudinal and lateral external loads. In this study, a series of experiments were carried out to assess the longitudinal and lateral resistance force of a wide sleeper and concrete panel type ACT. The required shear resistance force of the horizontal displacement restraint device (HDRD) was evaluated. Furthermore, a concrete block type anchor and a steel pipe type anchor were developed as HDRDs. The shear resistance force was decided based on the experimental results of horizontal shear tests for each anchor system. In addition, proper numbers and arrangement design guidelines for the HDRDs were suggested considering the shear resisting capacity and economics for HDRDs applied to ACT.