• Title/Summary/Keyword: 전기절연파괴

Search Result 590, Processing Time 0.029 seconds

Electrical characteristics for Multi-Nanocomposites throuh Surface Control of Epoxy/Nano_Micro $SiO_2$ Particles (Epoxy/Nano_Micro $SiO_2$입자 표면제어를 통한 멀티-나노콤포지트 전기적 특성연구)

  • Park, Young-Byum;Park, Hyun-Su;O, Chung-Yon;Kim, Hak-Jae;Park, Ki-Ryung;Lee, Dae-Kyoung;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.154-154
    • /
    • 2009
  • 본 연구는 고전압 전력기기인 몰드형변압기와 계기용 변성기인 CT, PT 절연특성에 유용한 Epoxy/Nano-Micro Mixture Composites(이하,ENMMC)를 개발하기위해 무엇보다 중요한 것은 Nano입자인 $SiO_2$_10nm입자의 표면을 제어하여 즉, 표면의 소수성을 크게 하여 나노입자의 균질한 분산을 얻은것이 무엇보다 중요하다. 개발된 Epoxy/$SiO_2$_10nm Nanocomposites와 Microcomposites을 기계적 전단응력을 이용하여 균질 혼합을 실시하였다. 이런 조건을 이용한 전기적특성을 측정하기위해 구대구 전극이 완전함침된 평등전계하에서 절연파괴전압을 측정하기 시편을 제조하였다. 마이크로입자의 충진함량을 일정하게 유지하여 나노입자 충진함량비율을 4가지로 변화시켜 절연파괴특성을 연구하였다. 충진함량이 나노입자의 경우 1wt%이하의 값이 상대적으로 우수한 절연파괴특성으로 와이블 플롯을 통하여 알수있었다. 상대적으로 멀티나노콤포지트의 형상파라미터가 큰 결과값을 얻을수 있었다. 그리고 스케일파리미터는 누적확률 밀도함수로서 63.2%에서 대단히 큰 초절연성의 절연소재를 개발할수 있었다.

  • PDF

Insulation Characteristic Analysis of SF6 Voltage Transformer between Windings (SF6 계기용 변압기의 권선간 절연특성해석)

  • Son, Ju-Wan;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1063-1064
    • /
    • 2011
  • GIS에 이상전압이 흐를 때, 이를 계측하여 전력기기의 손상 및 고장을 미연에 방지하기 위해 SF6 계기용 변압기를 사용한다. 이러한 계기용 변압기는 절연 파괴가 일어나지 않도록 설계하여야 한다. 특히, 절연은 권선 부분이 중요한 구성 요소로, 권선간의 전기적 절연특성해석을 통하여 전계강도를 완화할 수 있는 절연 설계를 수행하여야 한다. SF6 계기용 변압기는 SF6가스의 유전율이 절연물에 비해 적기때문에 가스에서의 전계 집중 현상이 생기게 된다. 본 논문에서는 SF6 계기용 변압기의 권선간 절연특성해석을 수행하였다. 1차 권선과 2차 권선의 형상을 모델링하고 유한요소법을 사용하여 축대칭 2차원 전계해석을 수행한다. 이 때 발생하는 전계강도를 예측하고 최대전계강도가 발생하는 영역을 찾는다.

  • PDF

기체절연파괴기구에 대하여

  • 오철한
    • 전기의세계
    • /
    • v.27 no.4
    • /
    • pp.3-6
    • /
    • 1978
  • (차례) 1.기체방전형식의 분류 2.기체방전기구 (1)Streamer (Primary와 Secondary) (2)Leader (3)Return Stroke와 Spark 3.문제점

  • PDF

Breakdown properties in relation with adhesion force for Polymeric meterial of the high voltage cable joints (초고압 지중선 고무접속재 제조용 고분자재료의 부품간 접착력에 기인하는 절연파괴특성)

  • Ji, Eung-Seo;Kwon, Yoon-Hyouk;Ko, Eui-Gon;Kim, Ji-Hwan;Lee, Sang-Jin;Choi, Soo-Geol;Yoon, Seung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.224-225
    • /
    • 2002
  • 초고압 지중선로를 연결하는 접속함의 절연재료는 최근 에폭시에서 고무재질로 변화되고 있는 추세이다. 본 논문에서는 접속재용 고무절연재료를 선정하기 위한 전기적, 기계적인 방법을 소개하였고, 전기적 절연특성과 접착특성간에 상관관계가 있는지에 대하여 고찰하였다. 특히 실제 제품의 절연-반도전간 interface특성을 모의할 수 있는 특수형태의 매입형 전극을 설계, 제조 및 시험후 동일시료에서 접착특성 확인용 시편을 채취 및 실험함으로써 전기적특성과 기계적특성간의 직접적인 상관관계를 규명할 수 있었다. 또한 실험을 통해서 초고압 지중선로용 접속함을 위한 최적의 고무재질 선정이 가능하였다.

  • PDF

AC Breakdown Characteristics of Pure Ar, $N_2$ Gas and Ar/$N_2$ Gas Mixutres under Uniform and Non-Uniform Fields (평등 및 불평등 전계하에서 순수 Ar, $N_2$가스와 Ar/$N_2$혼합 가스의 교류절연파괴 특성)

  • 이상우;김인식;이동인;이광식;김이국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, the AC breakdown characteristics of pure Ar and $N_2$gas with gas pressure range of 58.8~137.3[kPa] under uniform and non-uniform fields were investigated, and the measured values were compared with those in Ar/$N_2$gas mixtures with pressure varying. Summarizing the experimental results, the breakdown voltages of pure $N_2$gas, under uniform and non-uniform fields, were increased about 4.8 and 1.1 times than those of pure Ar gas, and the AC breakdown voltage increased with the pressure increasing. The breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of $N_2$gas. In case of Ar(85%)/$N_2$(15%) and Ar(70%)/$N_2$(30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.5 and 2.1 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[kPa]. Also, corona inception voltage of Ar(70%)/$N_2$(30%) gas mixtures under non-uniform field were increased about 1.5 times than those of pure Ar gas.

  • PDF

Insulation Characteristic of Moisturized Epoxy Compound (흡습된 에폭시 절연물의 절연 특성)

  • Kim, Dong-Myung;Park, Young-Keun;Kwon, Tae-Ho;Choi, Sun-Gyu;Lee, Byoung-Ho;Choi, Won-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.343-346
    • /
    • 2004
  • 가스절연개폐기의 절연물로 사용되는 에폭시가 흡습환경에 노출될 경우 절연내력은 급격히 저하된다. 에폭시 절연물에 함유되어 있는 수분은 어느 일정 온도에서는 가스 내 수분과 평형을 이루고 있지만 온도변화에 따라 수분은 이동되며 또 고전압 인가 시 절연체 표면은 열화 되어 장기간에 걸쳐 침식과 함께 Treeing 현상을 유발시킨다. 본 연구에서는 에폭시 절연물의 절연특성에 미치는 수분의 영향을 파악하기 위하여 실 계통에서 사용된 제품에 대해 AC 내전압시험 및 재료분석을 시행하였다. 분석결과, 표면의 파괴전압은 주수량에 따라 건조섬락전압의 최대 1/5까지 저하되었다.

  • PDF

A Distributed Characteristics of Water in Mineral Oil by Heating (오일에 용존된 수분의 온도 의존성)

  • Kim, Yoon-Hyoung;Han, Sang-Ok;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.46-48
    • /
    • 2007
  • 수분은 변압기의 절연 상태를 악화시키고 결국은 권선의 단락이나 1, 2차간의 절연 파괴로 이어져 변압기 고장의 주요 원인이 된다. 본 논문에서는 변압기의 절연물인 절연지와 절연유에 대해서 회복전압 측정법을 이용한 열화상태 진단에 대한 측정을 통해 변압기내에 존재하는 수분의 온도 특성을 실험했다. 실험 결과 변압기내 온도에 따른 수분은 절연유보다 절연지의 영향을 크게 받는 것으로 나타났고, 이는 변압기에 사용된 절연지인 셀룰로오스계 절연지의 수분 흡착성이 강하고, 온도가 증가함에 따라 수분을 생성하는 특성 때문인 것으로 판단되었다.

  • PDF

Fabrication of CNT sensor to measure degradation of transformer (변압기 열화 상태 감지를 위한 CNT 샌서 제작)

  • Kim, Yong-Kook;Shin, Kyoung;Ju, Byeong-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.159-160
    • /
    • 2008
  • 본 논문에서는 변압기 절연유 상태를 측정하여 변압기 열화정도를 분석할 수 있는 CNT센서를 개발하였다. 센서의 감지막 형성을 위해 MWCNT(multi walled carbon nanotube)로 CNT paste를 제작하고 이를 프린팅공정을 이용하여 그 규격을 최적화하였다. 제작된 CNT 센서를 이용하여 절연유 상태를 분석하고 이를 전기 화학적 분석을 통하여 변압기 열화 정도를 확인하였다. 변압기 사용 여부에 따른 센서의 특성과 절연유의 산가, 절연파괴전압 등 기타 특성과 비교하여 변압기 절연유의 열화정도를 확인하였다. 변압기 과부화 및 과전류에 의해 열화가 진행되어 전산가가 높아지면 이를 CNT 감지막의 전기적 특성 변화로 확인 할 수 있다. 개발된 IT 센서를 이용하면 변압기 열화 정도를 실시간으로 확인 할 수 있어 변압기 사용에 있어서 안정성 확보 및 유지관리에 경제성을 높일 수 있다.

  • PDF