• Title/Summary/Keyword: 전기절연테이프

Search Result 11, Processing Time 0.024 seconds

Fault Current Characteristics of a HTS tape (고온초전도테이프의 사고전류 특성)

  • Lee, Sung-Soo;Park, Kwon-Bae;Ryu, Kyung-Woo;Cha, Guee-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.804-806
    • /
    • 2000
  • 동일한 임계전류 특성을 갖는 Bi-2223 테이프에 전력기기의 실제 응용에서 발생되는 큰 사고전류를 고려한 임계전류보다 큰 과임계전류를 흘렸을 때 테이프의 온도상승 및 저항 특성을 중요한 인자에 대해 조사하였다. 냉각이 좋은 즉 비절연 테이프의 경우 온도상승은 없고, 표피효과에 의한 저항의 증가도 없고, 특히 비절연 테이프의 경우 과도 및 정상 상태 저항이 동일한 반면 절연 테이프의 경우 매우 상이하고, 전기절연 길이를 전압탭보다 길게만 해주면 길이에 무관하게 온도상승 및 저항이 동일하였으며 마지막으로 모재의 저항율이 상이하여도 임계전류만 동일하면 온도상승 및 저항은 유사함을 알 수 있었다.

  • PDF

Characteristics of Insertion Loss of Adhesive Tapes to Reduce Noise through Small Opening Hole (미세한 공혈을 통한 소음의 저감을 위한 접착 테이프 별 삽입손실 특성)

  • Yong Thung Cho
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.232-237
    • /
    • 2024
  • Adhesive tapes can be conveniently used for various applications by combination of materials requiring diverse mechanical strength and specific adhesives. Duct tape is usually readily available and one of the most widely used adhesive tapes. Duct tapes are composite materials with good mechanical strength consisted of fiber material, which is different from other tapes. In addition, electrical insulation tapes are used for very long period of time for insulating cables, and are also used for reinforcement of mechanical strength and increasing damping of cable in practice. Recently, variety of foam tapes and double-sided tapes are widely used in diverse applications. However, there is no previous work readily available clearly illustrating noise isolation performance of tapes. In present work, noise isolation performance of tapes is presented by measurement of insertion loss of variety of tapes on a small hole. Double-side foam tapes presented the best noise isolation performance among adhesive tapes measured in present work.

Analysis on the over current characteristics of metal insulated HTS coil (금속 절연 초전도 코일의 과전류 특성 해석)

  • Cho, Jeonwook;Sim, Kideok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1110-1111
    • /
    • 2015
  • 초전도 코일의 안정성(stability)을 향상시키기 방법으로 초전도 자석의 턴(turn) 사이의 절연을 없애는 무절연 코일(no-insulation coil) 및 금속 테이프를 같이 권선하는 금속절연 코일(metal insulation coil)이 제안되어 활발히 연구되고 있다. 본 논문에서는 고온초전도 코일의 열적, 전기적 메카니즘을 분석하기 위한 FEM 모델을 제시하고, 이를 사용하여 �치 시 고온 초전도 코일의 안정성 향상 정도를 해석한다.

  • PDF

공지사항

  • Korea Electronics Association
    • Journal of Korean Electronics
    • /
    • v.4 no.1
    • /
    • pp.147-149
    • /
    • 1984
  • PDF

Manufacturing technology of two-layer self bonding insulating tape (이중절연 자기융착테이프 제조기술)

  • 조용석;이철호;심대섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.890-893
    • /
    • 2001
  • Two-layer self bonding insulating tape consists of butyl rubber(IIR ; Isobutylene-isoprene rubber) adhesive layer and polyethylene protective film. Butyl rubber have inherent characteristics such as resistance to corrosion and water, low temperature flexibility, excellent electrical insulating properties also resistance to environmental effect such as ozone and ultraviolet. Polyethylene film was used for the purpose of good insulating properties and resistance to ozone and ultraviolet. The tape was manufactured using extrusion and calender method.

  • PDF

A Study on LLC Resonant Transformer Design with the Winding Method of Automatic Type suitable for LLC Resonant Converter (LLC 공진 컨버터에 적합한 자동화 권선 LLC 공진 변압기 설계에 관한 연구)

  • Bae, Jun-Hyung;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1108-1111
    • /
    • 2019
  • This paper presents the comprehensive transformer design methodology with the winding method of automatic type suitable for LLC resonant converter. The problem with conventional LLC resonant transformer is that it is difficult to implement the winding method of automatic type because all windings are wound in one bobbin. Therefore, the LLC resonant transformer, which is capable of the winding method of automatic type to multiple section bobbin without insulation tape and barrier tape, is proposed in this paper and the design procedure of the proposed LLC resonant transformer is also shown. Modeling and analysis of the proposed LLC resonant transformer using Maxwell 3D simulation tool are described in detail and a protype 150W LLC resonant converter using the proposed LLC resonant transformer manufactured by 3D modelling is also verified through the experimental test.

Electrical characteristics of class-F groundwall insulation tapes for stator windings (고정자 권선용 F종 주절연 테이프의 전기적 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun;Son, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1679-1681
    • /
    • 2004
  • Class-F and B resin-rich type insulating tapes are generally used for the ground wall insulations of respective air-cooled and water-cooled stator windings in larger turbine generators. In this paper, their electrical properties coupled with aging times in higher temperature than designed one in normal condition were experimentally investigated and the results of two comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich tapes currently used arc composed of six and a half 3-layer sheets that arc structured with mica paper, the top and bottom supports of it respectively, and the epoxy resin to bind them tightly. The results for breakdown voltage and strength on the cured specimens were presented, which were composed of the unaged, the aged accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The surface and volume resistivities on them were measured and the results are also presented to make a comparative test for the initial electrical characteristics.

  • PDF

Study of Fire Examples for Electrical Wire Short and Insulated Coating Melting by Heating Including Automotive Engine Room (자동차 엔진룸 관련 전기 배선의 단락 및 열에 의한 절연피복 용융에 대한 화재사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Youm, Kwang Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.15-19
    • /
    • 2013
  • This paper is to analyze and study the cause of fire examples produced because of short phenomenon by electric connecting damage and contacting engine over-heating with combustible materials in engine room of vehicle. In the first example, it knew the fact that the fire produced by contacting with body of vehicle because of loosed of bracket bolt for wire fixing that installed on the transmission case the battery power cable supply the power from battery of engine room to starting motor. In the second example, it certified the fire by short phenomenon because of insulation tape melting wound wiring lined from battery to starting motor. In the third example, it sought for fire's cause that melting phenomenon the wire coating by overheated engine as the wire disconnected with connector by the vibration. Therefore, the fire of system including engine electric made in the danger the people in the car by failure of engine and other system. And than, the car's driver must manage and examine a vehicle conscientiously.

Mechanical characteristics of class-F groundwall insulation tapes for stator windings (고정자 권선용 F종 주절연테이프의 기계적 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun;Son, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1676-1678
    • /
    • 2004
  • Class-F resin-rich type insulating tapes are generally used for the groundwall insulations of the large turbine generators with air-cooled and hydrogen-cooled stator windings. In this paper, mechanical strength properties degraded over aging time in higher temperature than designed one in normal condition were experimentally investigated and the results of comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich insulating tapes with composite material of Mica/Epoxy/support currently were used in this test. The tests for tensile and flexural strength properties were conducted with the specimens which were composed of unaged and the aged specimens accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The tensional strength was only measured for the unaged specimens and the results are also presented to make a comparative test for their initial mechanical characteristics.

  • PDF

Study on Condition of Fabrication Processing for R. F. High-power Unit Capacitor and Electrical Characteristics According to Addition of ZrO2 (고주파용 대용량 단위 유전체 제조공정과 ZrO2 첨가에 따른 전기적 특성 연구)

  • Ahn, Young-Soo;Kim, Joon-Soo;Park, Joo-Seok;Kim, Hong-Soo;Han, Moon-Hee;No, Kwang-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.822-828
    • /
    • 2002
  • Fabrication and electrical characterization of R. F. High-power unit capacitors were investigated to study on condition of fabrication processing for R. F. High-power unit capacitor and electrical characteristics according to addition of $ZrO_2$. The unit capacitors were fabricated using tape casting. The optimum mixture ratio of dielectrics and mixing binder for the slurry fabrication was 57.5∼60.0: 42.5∼40.0 wt%. The slurry viscosity was 4000∼5000 cps and casting state of green tape fabricated using these slurry was excellent. Optimum stacking was made by 200 kg/$cm^2$ pressure with 80$^{\circ}C$ heating. $ZrO_2$ was added to improve the electrical characteristics of unit capacitor, especially breakdown characteristics. The dielectric constant and loss factor of the unit condenser having different $ZrO_2$ amounts was not changed in the addition range of 1 to 5 wt%. Also, dielectric constant was not changed in the frequency range of 10 to 500 kHz. It was found that characteristics of resistance voltage was improved through the formation of $CaZrO_3$ and the reduction of particle size as about 3wt% $ZrO_2$ was added.