• Title/Summary/Keyword: 전기적 특성

Search Result 13,345, Processing Time 0.05 seconds

Changes in the Level of Various Nitrogen Compounds During the Ripening of Blue Cheese Made with Mucor Rennet (Mucor Rennet으로 제조(製造)한 Blue Cheese 숙성중(熟成中) 각종(各種) 질소화합물(窒素化合物)의 변화(變化))

  • Kim, Jong Woo;Lee, Nag Jin
    • Korean Journal of Agricultural Science
    • /
    • v.16 no.2
    • /
    • pp.201-211
    • /
    • 1989
  • This experiment was carried out to study the practical utility of Mucor rennet in making Blue cheese and to investigate the changes in the level of various nitrogen compounds. 1. The Mucor rennet cheese, the calf rennet cheese and the mixed rennet cheese did not show any significant difference in their yields. 2. The dry matter contents of Blue cheese was increased during the ripening and the levels of Mucor rennet did not have any influence in these respect. 3. The water soluble nitrogen contents of Blue cheese increased during ripening. On 0 day of ripening the Mucor rennet cheese contained water soluble nitrogen than the calf rennet cheese. On 40 days of ripening the mixed cheese contained less water soluble nitrogen than the calf rennet cheese. 4. Non protein nitrogen, peptone amino nitrogen, water soluble protein nitrogen, proteose nitrogen and peptone nitrogen appeared to contain similar levels of water soluble nitrogen. 5. The results of electrophoresis indicated a greater degredation on as-casein and ${\beta}$-casein in the Blue cheese made with Mucor rennet than in those made with calf rennet. On 60 days of ripening the mixed cheese more casein than did the Mucor rennet cheese. 6. The free amino acid contents of the Mucor rennet cheese was higher than the calf rennet cheese at 60 days of ripening.

  • PDF

Relationship of soil profile strength and apparent soil electrical conductivity to crop yield (실시간 포장에서 측정한 토양 경도 및 전자장 유도 전기전도도와 작물수량과의 관계)

  • Jung, Won-Kyo;Kitchen, Newell R.;Sudduth, Kenneth A.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.2
    • /
    • pp.109-115
    • /
    • 2006
  • Understanding characteristics of claypan soils has long been an issue for researchers and farmers because the high-clay subsoil has a pronounced effect on grain crop productivity. The claypan restricts water infiltration and storage within the crop root zone, but these effects are not uniform within fields. Conventional techniques of identifying claypan soil characteristics require manual probing and analysis which can be quite expensive; an expense most farmers are unwilling to pay. On the other hand, farmers would be very interested if this information could be obtained with easy-to-use field sensors. Two examples of sensors that show promise for helping in claypan soil characterization are soil profile strength sensing and bulk soil apparent electrical conductivity (ECa). Little has been reported on claypan soils relating the combined information from these two sensors with grain crop yield. The objective of this research was to identify the relationships of sensed profile soil strength and soil EC with nine years of crop yield (maize and soybean) from a claypan soil field in central Missouri. A multiple-probe (five probes on 19-cm spacing) cone penetrometer was used to measure soil strength and an electromagnetic induction sensor was used to measure soil EC at 55 grid site locations within a 4-ha research field. Crop yields were obtained using a combine equipped with a yield monitoring system. Soil strength at the 15 to 45 cm soil depth were significantly correlated to crop yield and ECa. Estimated crop yields from apparent electrical conductivity and soil strength were validated with an independent data set. Using measurements from these two sensors, standard error rates for estimating yield ranged from 9 to 16%. In conclusion, these results showed that the sensed profile soil strength and soil EC could be used as a measure of the soil productivity for grain crop production.

Characterization of Ni-YSZ cermet anode for SOFC prepared by glycine nitrate process (Glycine nitrate process에 의한 제조된 SOFC anode용 Ni-YSZ cermet의 물성)

  • Lee, Tae-Suk;Ko, Jung-Hoon;Lee, Kang-Sik;Kim, Bok-Hee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.1
    • /
    • pp.21-26
    • /
    • 2011
  • Ni-YSZ (Yttria Stabilized Zirconia) composite powders were fabricated by glycine nitrate process. The prepared powders were sintered at $1300{\sim}1400^{\circ}C$ for 4 h in air and reduced at $1000^{\circ}C$ for 2 h in a nitrogen and hydrogen atmosphere. The microstructure, electrical conductivity, thermal expansion and mechanical properties of the Ni-YSZ cermets have been investigated with respect to the volume contents of Ni. A porous microstructure consisting of homogeneously distributed Ni and YSZ phases together with well-connected grains was observed. It was found that the open porosity, electrical conductivity, thermal expansion and bending strength of the cermets are sensitive to the volume content of Ni. The Ni-YSZ cermet containing 40 vol% Ni was ascertained to be the optimum composition. This composition offers sufficient open porosity of more than 30 %, superior electrical conductivities of 917.4 S/cm at $1000^{\circ}C$ and a moderate average thermal expansion coefficient of $12.6{\times}10^{-6}^{\circ}C^{-1}$ between room temperature and $1000^{\circ}C$.

Synthesis of (Ba0.5Sr0.5)0.99Co0.2Fe0.8O3-δ (BSCF) and the Electrochemical Performance of the BSCF/GDC(Buffer)/ScSZ ((Ba0.5Sr0.5)0.99Co0.2Fe0.8O3-δ(BSCF)의 합성 및 BSCF/GDC(Buffer)/ScSZ의 전기화학적 특성)

  • Lim, Yong-Ho;Hwang, Hae-Jin;Moon, Ji-Woong;Park, Sun-Min;Choi, Byung-Hyun;Lee, Mi-Jai
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.6 s.289
    • /
    • pp.369-375
    • /
    • 2006
  • [ $(Ba_{0.5}Sr_{0.5})_{0.99}Co_{x}Fe_{1-x}O_{3-{\delta}}$ ] [x=0.8, 0.2](BSCF) powders were synthesized by a Glycine-Nitrate Process (GNP) and the electrochemical performance of the BSCF cathode on a scandia stabilized zirconia, $[(Sc_{2}O_3)_{0.11}(ZrO_2)_{0.89}]-1Al_{2}O_3$ was investigated. In order to prevent unfavorable solid-state reactions between the cathode and zirconia electrolyte, a GDC ($Gd_{0.1}Ce_{0.9}O_{2-{delta}}$) buffer layer was applied on ScSZ. The BSCF (x = 0.8) cathode formed on GDC(Buffer)/ScSZ(Disk) showed poor electrochemical property, because the BSCF cathode layer peeled off after the heat-treatment. On the other hand, there were no delamination or peel off between the BSCF and GDC buffer layer, and the BSCF (x = 0.2) cathode exhibited fairly good electrochemical performances. It was considered that the observed phenomenon was associated with the thermal expansion mismatch between the cathode and buffer layer. The ohmic resistance of the double layer cathode was slightly lower than that of the single layer BSCF cathode due to the incorporation of platinum particle into the BSCF second layer.

A Study on the Salinity Variation of Salt Water in an Estuary (하구(河口)의 해수(海水)의 염도변동(鹽度變動)에 관한 연구(研究) - 군산외항(群山外港)부근을 중심(中心)으로 -)

  • Lee, Jong Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 1981
  • Since the estuary is a very complex place in which the sea water and the fresh water meet, it is very difficult to make a general analytical description of salinity distribution in the estuary. As an attempt to investigate the characteristics of salinity variation in the estuary of the Geum River, the field observations were continuously carried out at three points near the Gunsan New Harbor at the time intervals 1 to 1.5 hours during one tidal cycle and the data were analysed. The following results were obtained; 1. It was reconfirmed that most of the ratios of the salinity to the conductivity were widely distributed between the range of 0.5 to 1.0. 2. The salinity showed the peak at the high water, and then it began to decrease gradually and had the lowest value 0 to 2 hours after the low water. 3. The density current was generally the intense mixing type and when the river discharge was very large it was of the moderate type. 4. The vertical salinity distribution was not significantly affected by the wave height. 5. The maximum vertical salinity differences were generally less than 10 g/l and the time of the occurrence of the minimum value was 0 to 3 hours after the low water when in the spring tide and in the neap tide it occurred 2 to 3 hours after the high water.

  • PDF

Waveform Sorting of Rabbit Retinal Ganglion Cell Activity Recorded with Multielectrode Array (다채널전극으로 기록한 토끼 망막신경절세포의 활동전위 파형 구분)

  • Jin Gye Hwan;Lee Tae Soo;Goo Yang Sook
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.148-154
    • /
    • 2005
  • Since the output of retina for visual stimulus is carried by neurons of very diverse functional properties, it is not adequate to use conventional single electrode for recording the retinal action potential. For this purpose, we used newly developed multichannel recording system for monitoring the simultaneous electrical activities of many neurons in a functioning piece of retina. Retinal action potentials are recorded with an extra-cellular planar array of 60 microelectrodes. In studying the collective activity of the ganglion cell population it is essential to recognize basic functional distinctions between individual neurons. Therefore, it is necessary to detect and to classify the action potential of each ganglion cell out of mixed signal. We programmed M-files with MATLAB for this sorting process. This processing is mandatory for further analysis, e.g. poststimulus time histogram (PSTH), auto-correlogram, and cross-correlogram. We established MATLAB based protocol for waveform classification and verified that this approach was effective as an initial spike sorting method.

  • PDF

An Electric Load Forecasting Scheme with High Time Resolution Based on Artificial Neural Network (인공 신경망 기반의 고시간 해상도를 갖는 전력수요 예측기법)

  • Park, Jinwoong;Moon, Jihoon;Hwang, Eenjun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.11
    • /
    • pp.527-536
    • /
    • 2017
  • With the recent development of smart grid industry, the necessity for efficient EMS(Energy Management System) has been increased. In particular, in order to reduce electric load and energy cost, sophisticated electric load forecasting and efficient smart grid operation strategy are required. In this paper, for more accurate electric load forecasting, we extend the data collected at demand time into high time resolution and construct an artificial neural network-based forecasting model appropriate for the high time resolution data. Furthermore, to improve the accuracy of electric load forecasting, time series data of sequence form are transformed into continuous data of two-dimensional space to solve that problem that machine learning methods cannot reflect the periodicity of time series data. In addition, to consider external factors such as temperature and humidity in accordance with the time resolution, we estimate their value at the time resolution using linear interpolation method. Finally, we apply the PCA(Principal Component Analysis) algorithm to the feature vector composed of external factors to remove data which have little correlation with the power data. Finally, we perform the evaluation of our model through 5-fold cross-validation. The results show that forecasting based on higher time resolution improve the accuracy and the best error rate of 3.71% was achieved at the 3-min resolution.

Development of rotor overlay welding process (로타 오버레이 용접공정 개발)

  • Lee, Kyong-Woon;Kim, Dong-Jin;Kang, Sung-Tae
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.12-12
    • /
    • 2009
  • 터빈에서 핵심부품인 로터는 블레이드를 원심 운동시키는 대형 단조강이며, 고압의 증기 조건에서 고속회전하며 고온에서 운전과 저온에서 과속시험 동안 높은 원심력을 받는다. 또한 기동/정지 천이 동안 열응력을 받기 때문에, 이러한 운전조건에 부합되는 소재로서는 높은 Creep 강도 및 피로강도를 가지는 CrMoV type의 강종이 사용되어져 왔다. 발전소의 대용량화 및 고온화에 따라 종래의 증기조건에서 사용되어져 왔던 1%CrMoV강은 내산화성 및 내부식성이 문제가 되어 더 이상 사용이 불가하며, 고온/고압하에서도 우수한 소재 특성을 가지는 12%Cr강의 사용이 필수적이다. 그러나 12%Cr강으로 제작되는 로타는 Cr 양이 높기 때문에 저널부에 Galling 또는 Scuffing 이라 불리는 부적절한 마모현상과 사용 중 소착이 발생하기 쉬운 단점이 있기 때문에, 저널부에 Cr 함유량 2~3% 이하의 저합금강을 오버레이 용접하여 육성하는 일체형 가공구조의 로타 저널부가 주목되어 왔다. 따라서 본 연구에서는 Large scale 로타가 용접 도중 급열 및 급냉이 되지 않으면서 균일한 온도로 일정 시간 유지할 수 있는 열관리 장치 개발, 최적 오버레이 용접조건 선정 및 용접부 건전성 시험 평가를 통하여 12%Cr 로타 저널부의 최적 오버레이 용접공정을 확립하고자 하였다. 용접 열관리 장치는 전기저항 가열방식을 적용하고 있으며 용접이 최종 완료되기 전까지 로타 제품 전체는 $93^{\circ}C$이상의 온도로 유지 되어져야 하며, 규정 용접후열처리 온도는 $650^{\circ}C{\pm}14^{\circ}C$ 이다. 또한 로타 오버레이 용접은 모재 Set up $\Rightarrow$ 용접예열 $\Rightarrow$ GTA용접 $\Rightarrow$ SA용접 $\Rightarrow$ 용접후열(Post heating) $\Rightarrow$ 용접후열처리(PWHT) $\Rightarrow$ 정삭가공 $\Rightarrow$ NDE(UT) 순으로 수행 되어진다 실제 로타의 1/3 Scale로 시험편을 제작하여, 오버레이 mockup 시험을 수행한 후 화학성분, 경도 분포, 인장강도, 충격인성 및 굽힘시험을 수행한 결과, 오버레이 용접에서 요구되어지는 용접 물성값을 만족하는 것으로 확인되었다. 또한 균열 등의 선형 결함이나 기공, 슬라그 혼입과 같은 결함은 관찰되지 않았으며, 용접 시 아크의 안정성과 슬라그의 박리성은 양호하였으며 비드의 외관도 미려하여 용접 작업성도 양호하였다.

  • PDF

ARC Discharge Sound Source in Underwater (수중 아-크 방전음원에 관한 연구)

  • Chang, Jea-Hwan;Chang, Jee-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.12-18
    • /
    • 1985
  • In general the impulse sound sources of underwater generated by electric arc discharge had used static energy of the charged capacitors. The author proposed an underwater arc discharge sound source using secondary voltage of high voltage transformer without capacitors. The arc discharge device was composed of a high voltage transformer and a switching system. The impulse current in the primary turn of the high voltage transformer is controlled by the switching system and inductive current of the secondary turn in the high voltage transformer is used in making impulsive arc discharge. A series of experiment have been carried out to observe the acoustic characteristics of the impulse sound source generated by the arc discharge. The results obtained were as follows: 1. Secondary current at the time of arc discharge keeps after ohm's law in the beginning and the maximum current flows out as soon as arc discharge breaks out. 2. A time difference between a start of applied current and a generation of arc discharge sound is the 3msec and it is generated arc sound when breaking down electric insulation at maximum voltage. 3. The sharper the end of electrodes and the higher the secondary voltage, the higher the sound pressure level. 4. Arc discharge sound was generated even at the distance of 100cm between electrodes and was stably reproductive at the gap of 1cm to 100cm. 5. Electric arc discharge sound wave is a shock wave of pulse-width of 0.15msec and spectral distribution of it is plenty of low frequency components less than 10 KHz.

  • PDF

Spatial Division of Labor in Korea and The Characteristics of Kumi Local Labor Market (공문적 분업과 지방 노동시장의 특성에 관한 연구 -구미공업단지 섬유.전기전자산업을 중심으로-)

  • 박원석
    • Journal of the Korean Regional Science Association
    • /
    • v.6 no.1
    • /
    • pp.11-38
    • /
    • 1990
  • The purpose of this thesis is, first to present the spatial division of labor in Korea and its mechanism, and second, to elucidate the organic integral relation between local labor market and local community by studing the mechanism that the spatial division of labor is projected into the individual lacal labor marker, and reproduction of labor force process in this local labor market. According to this purpose, the theoretical frame of this analysis is done, the positive analysis is made and Kumi is choosed as its analysis case area. The main data is from 'Survey Report on Manufacturing Idustry Wage Conditions' published by Minimum Wage Council, Ministry of Labour and from the questionnaires and interview on textile industry and electric electronics industry firms in Kumi Export Industrial Estate. The following are the results of this study. 1. The mechanism of spatial division of labor in Korea, seen through the employment structure index, is accelerating the regional discrimination by fixing the regional hierarchisation between Seoul (or Seoul Metropolitan Area as expanded Seoul) and other areas. But it is also developing highly the regional employment structure at the level of technical division of labor, since the spatial division of labor in Korea is leaded by large firms and influenced by the policy for regional development. 2. Local labor market is formed in Kumi area and its delimitation is Kumi city. The employment structure of Kumi local labor market is occupying lower hierarchy division at management hierachical level and occupying upper hierarchy division at the level of technical division of labor, and brand plants of large firs are determinating and dominating this emplogment structure. These bdranch plants of large firs are forming more favorable and stabel labor marker than locally controlled ploants in Kumi local labor market. But the reproduction of labor force process in Kumi local labor market is not fully carried out and leaked into central city, therefore Kumi is now becoming an unstable local community, suffering from large movement of population. This is because Kumi local labor market is found not for itself, but by the state policy and externally controlled plants of large firms, and therefore no potentiality to control and to absorb the exterior influences is built in Kumi local labor market. 3. The case firms A, B have spatial division of labor between decision-making function and production function, and between upper management hierachical labor force and lower management hierachical labor force in internal labor market.

  • PDF