• Title/Summary/Keyword: 전기적인 자극

Search Result 481, Processing Time 0.032 seconds

Effects of Functional Electrical Stimulation on the Balance of Hemiplegic Patients (기능적 전기자극 치료가 편마비 환자의 균형에 미치는 영향)

  • Kim, Yong-Cheol;Lee, Suk-Min;Song, Chang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.97-111
    • /
    • 2004
  • This study, adopting the pretest-post test experimental study, is designed to find out how the functional electrical stimulation makes effect on the balance of a patient with spasticity of the ankle plantarflexor muscle caused by hemiplegic after stroke. The 46 subjects for this study were randomly sampled out of the patients who were hospitalized from September 1, 2003 to November 30, 2003 in H sanitarium in Yangpyung. The patients were with spasticity of the ankle plantarflexor muscle caused by hemiplegic after stroke and able to walk without supporting implements. The purpose of the study is firstly to analyze the change of ROM, FRTof a patient with spasticity of the ankle plantarflexor muscle when the functional electrical stimulation is applied and secondly to find out how the sex, age, height, weight, part of the diagnosis, duration of pain, experience of relapse and getting hurt from a fall of a patient make effect on the change. The experimental group for the study is divided into two to compare the differences of the effect. The exercising treatment only was performed for the conrtol group, and the functional electrical stimulation to the ankle dorsiflexor muscle as well as the exercising treatment was applied to the experimental group. The ROM test was performed to check the range of motion of the ankle with a double armed universal goniometer. The test was done 3 times to take an average. FRT were performed to check the balance. The statistical test was conducted using the SPSS 10.0/PC program by means of the following methods: χ2-test and t-test for testing homogeneity between the groups; paired t-test, independent sample t-test, F-test, and two-way ANOVA for analyzing the changes before and after the treatment. The levels of statistical significance of all the data were maintained at p<.05. According to the test, ROM has more decreased in experimental group than in control group when the functional electrical stimulation was applied only to the experimental group. However, the significant statistic difference was not shown (p=.059). FRT showed remarkable differences in the experimental group compared to the control group, showing the significant statistic difference (p=.000). On the one hand, the change of ROM, FRT related with the sex, age, height, weight, part of the diagnosis, and experience relapse was a meaningless minimum value. The change of ROM related to the duration of pain and the experience of falling down was also meaningless. However, FRT showed significant statistic difference (p<.05). According to the test above, the application of functional electrical stimulation to a patient with spasticity of the ankle dorsiflexor muscle caused by hemiplegic after stroke makes significant effect on the balance of a patient, but the result has nothing with the sex, age, height, weight, part of the diagnosis, duration of pain, experience of relapse and getting hurt from a fall of a patient. However, it is regarded to give contribution to the balance improvement of a patient. Therefore, this study expects to be a valuable clinical material for a patient with spasticity.

  • PDF

Induction of Spontaneous Neutrophil Apoptosis by 4-O-Methyl-Ascochlorin, A Prenyl Phenol Compound (프레닐 페놀계 항생제인 4-O-methyl-ascochlorin에 의한 호중구 세포사멸의 유도)

  • Son Dong-Aoon;Lee Sun-Young;Lee Min-Jung;Park Joo-In;Hong Young-Seob;Lee Yong-Hwan;Chang Young-Chae;Kwak Jong-Young
    • Journal of Life Science
    • /
    • v.16 no.1
    • /
    • pp.30-36
    • /
    • 2006
  • Neutrophils are short-lived leukocytes that play a vital role in immune responses to bacteria, yeast, and fungi. This study was performed to investigate the effect of 4-O-methyl-ascochlorin (MAC), an anti-tumor, antibiotic, and anti-fungal prenyl-phenol compound on the spontaneous apoptosis of human neutrophils. MAC time- and dose-dependently accelerated the spontaneous apoptosis of human neutrophils. The effect of MAC on neutrophil apoptosis was blocked by pre-treatment of the neutrophils with specific inhibitors of pancaspase (zVAD-fmk), caspase-8 (zIETD-fmk), or caspase-3 (zDEVD-fmk). The cleavage of procaspase-8 and procaspase-3 was increased by MAC. Mitochondrial permeability, which was measured by the retention of $DiOC_6(3)$, was dose-de-pendently increased by MAC but the change of mitochondrial permeability was not blocked by pretreatment of neutrophils with zIETD-fmk. These results suggest that MAC induces neutrophil apoptosis by caspase-8-dependent but mitochondria-independent manner.

Effects of noninvasive electrical stimulation on osseointegration of endosseous implants;A histomorphometric evaluation in the rabbit tibia (비침습적인 전기자극이 임프란트의 골융합에 미치는 영향;토끼경골에서의 조직계측학적 평가)

  • Sohn, Sung-Bae;Park, Jin-Woo;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.635-648
    • /
    • 2005
  • The procedure that enhances osteogenesis and shortens the healing period is required for successful implant therapy. It has been introduced that osteogenesis is enhanced by the generation of electric field. Many researchers have demonstrated that application of electric and electromagnetic field promote bone formation. It also has been shown that electrical stimulation enhances peri-implant bone formation. Recently, several investigators have reported that noninvasive electrical stimulation using negatively charged electret such as polytetrafluoroethylene(PTFE) promotes osteogenesis. Therefore, we were interested in the effect of noninvasive electrical stimulation using negatively charged electret on the periimplant bone healing. After titanium implant were installed in the proximal tibial metaphysis of New Zealand white rabbit, negatively charged PTFE membrane fabricated by corana dischage was inserted into the inner hole of the experimental implant and noncharged membrane was applied into control implant. After 4 weeks of healing, histomorphometric analysis was performed to evaluate peri-implant bone response. The histomorphometric evaluations demonstrated experimental implant tended to have higher values in the total bone-to-implant contact ratio(experimental ; $49.9{\pm}13.52%$ vs control ; $37.5{\pm}19.44%$) , the marrow bone contact ratio(experimental ; $34.94{\pm}13.32%$ vs control ; $24.15{\pm}13.69%$), amount of newly formed bone in the endosteal region(experimental ; $1.00{\pm}0.30mm$ vs control ; $0.61{\pm}0.24mm$) and bone area in the medullary canal(experimental ; $13.55{\pm}4.98%$ vs control ; $9.03{\pm}3.05%$). The mean values of the amount of newly formed bone(endosteal region) and bone area(medullary canal) of the experimental implant demonstrated a statistically significant difference as compared to the control implant(p<0.05). In conclusion, noninvasive electrical stimulation using negatively charged electret effectively promoted peri-implant new bone formation in this study. This method is expected to be used as one of the useful electrical stimulation for enhancing bone healing response in the implant therapy

The Influence of Imipramine on the Effect of Clonidine in Pithed Rats (뇌척수제거 흰쥐에서 Clonidine효과에 미치는 Imipramine의 영향)

  • Kang, S.C.;Lee, W.S.;Rhim, B.Y.;Hong, K.W.
    • The Korean Journal of Pharmacology
    • /
    • v.20 no.2
    • /
    • pp.7-14
    • /
    • 1984
  • In pithed rats, rising in diastolic blood pressure by clonidine, when intravenously injected, is expressed as the postsynaptic action, and inhibitory action on electrical stimulation-induced tachycardia by clonidine is expressed as the presynaptic inhibitory action. In this study it was aimed to observe the inhibitory effect of imipramine caused by a single and chronic administration on both postsynaptic and presynaptic action of clonidine in pithed rats, and discussed in relation with the mechanism of antidepressant action of imipramine. 1) A rise of diastolic blood pressure by clonidine was not antagonized by prazosin, but by both phentolamine and piperoxan. 2) The inhibition by clonidine of tachycardia which was induced by electrical stimulation was also antagonized by phentolamine and piperoxan, but not by prazosin. 3) The increase in diastolic blood pressure in response to clonidine was inhibited by both a single or chronic administration with imipramine (20 mg/kg). It was more pronounced in the latter. 4) The inhibitory action of clonidine on the tachycardia was markedly inhibited by both types of administration with imipramine, between which there showed little difference. It is concluded that the presynaptic ${\alpha}_2-adrenoceptor$ is rather sensitively affected by a single administration with imipramine, and a long-term imipramine treatment may inhibit both pre- and postsynaptic ${\alpha}_2-adrenoceptors$, simultaneously. Furthermore, it was seemed unlikely that these results provide the evidence :to support the fact that the subsensitivity of presynaptic ${\alpha}_2-adrenoceptor$ may be the mechanism of action of tricyclic antidepressant.

  • PDF

Effects of Neuromuscular Electrical Stimulation on Muscle Wasting with Cancer Patient: A Systematic Review (신경근전기자극치료가 암 환자의 근육 손실에 미치는 영향: 체계적 문헌고찰)

  • Eun Soo Park;Jong Hee Kim;Soo Dam Kim;Dong Hyun Kim;Eun Jung Lee;Min Seok Oh;Hwa Seung Yoo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.15-29
    • /
    • 2023
  • Objectives The purpose of this study is to systematically review the effects of Neuromuscular Electrical Stimulation treatment on muscle wasting in cancer patients. Methods Randomized controlled trials (RCTs) were searched from seven online databases (PubMed, Cochrane Library, EMBASE, China National Knowledge Infrastructure, Oriental Medicine Advanced Searching Integrated System, Korean studies Information Service System, Research Information Sharing Service. The selected RCTs were evaluated for methodological quality through the Cochrane RoB. Results A total of 126 articles were identified, and 4 randomized controlled trials were selected for systematic review. In one study, it was found that there were statistically significant improvements in the Health-Related Quality of Life (FACTH&N total score, p<0.001). Additionally, significant effects were observed in measurements that represented the size of the quadriceps muscle (cross-sectional area of Vastus lateralis and Rectus femoris, p=0.004), maximum muscle strength, the twitch response of resistance muscles, and voluntary activation (p<0.001). However, no significant differences were observed between the intervention and control groups in terms of quadriceps muscle strength in two other studies (p>0.05). Lastly, while one study showed no significant differences in muscle fiber characteristics between the two groups, it did report significant improvements in measurements related to mitochondria within muscle tissue and muscle strength in the intervention group (p<0.05). Conclusions Neuromuscular electrical stimulation can be a method used to improve muscle strength in muscle wasting of cancer patients, but it is difficult to see its effects as significant compared to other treatments.

Empirical Study of Key Factors in Satisfaction with Subway Services (지하철 이용만족도 결정요인에 관한 실증적 연구 -서울지역을 중심으로-)

  • Shim, Jong-Seop;Jeon, Ki-Heung
    • Korean Business Review
    • /
    • v.13
    • /
    • pp.49-66
    • /
    • 2000
  • Despite the fact that understanding customers satisfaction with transportation services is a subject of great importance, authors, so far, found no systematic researches referred to that issue. From this point, studying the satisfaction with subways services can be extremely useful. Empirical study of key factors in the satisfaction with subway services is the departure point, which holds as objectives, and we believe, will contribute to overall increasing in the number of subways services used and in the amount of public benefits derived from that usage. In order to achieve these goals: First, several items referred to some key factors in the satisfaction of subway usage were systemized. Second, a research of specific weights attached to those key factors by subway passengers was conducted. Knowledge of the satisfaction variables system can provide deep insights into ones perceptual experience when using a subway. The results were as follows: Various interrelated factors compose a passengers satisfaction with subway services. People do not just use subway passively; a number of key factors, like physical and personal services, exact timing, easiness to access etc. determine the passengers satisfaction with subway. In order to find out specific weights of these key factors multiple regression analysis was employed. Results showed that satisfaction with subway is determined by (in order of importance) easiness to access, quality of physical services, friendliness of working stuff and timing exactness. According to the findings, passengers do not use subway as a simple mean of transportation, rather they perceive it as a complex combination of environmental elements and overall satisfaction depends on these various factors. Therefore, to learn passengers satisfaction with subways services, passengers subway experience must be thoroughly studied and analyzed, and this is where papers value resides.

  • PDF

Effects of clomiphene citrate on ovarian function and embryo developmental capacity in the rat (랫드에 있어서 클로미펜 시트레이트가 난소기능 및 수정란 발육성에 미치는 영향)

  • Yun, Young-won;Kwun, Jong-kuk
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.1
    • /
    • pp.15-24
    • /
    • 1992
  • The effects of CC the ovulatory response, oocyte normality, ovarian steroidogenesis and subsequent embryo developmental potential were examined in PMSG-treated rats. On Days of 25~27 of age, immature female Sprague Dawley rats were treated with three different doses(0.05, 0.1 or 1.0mg /day) of clomiphene citrate or vehicle. The females subsequently received 4IU PMSG on Day 28 and/or 10IU hCG on Day 30, and were killed on Day 31. Some females given 0.1mg CC or vehicle with 4IU PMSG were then mated and killed on Days 2, 3, 4 and 5 of pregnancy. Compared to vehicle(control) group, by increasing the doses of CC, there were a significant decrease in the ovulatory response as judged by both the proportion of rats ovulating and the mean number of oocytes per rat and a marked reduction of ovarian weight. The increasing doses of CC substantially promoted the degeneration(%) of oocytes ovulating in a dose-dependent manner. The CC-mediated inhibitions of the ovulatory response and ovarian weight were oompletely overcome by a subsequent treatment of hCG. Increasing doses of CC resulted in a siginificant elevation of serum estradiol with the decreased levels of progesterone and androgens. The additive treatment with hCG was effective to reduce the elevation of estradiol and to increase the reduction of progesterone produced by high dose(1.0mg) of CC. The preimplantation embryos recovered from 0.1mg CC-treated pregnant rats demonstrated a progressive early loss from Day 3 of pregnancy with a significant increase in the percentage of degeneration during all periods examined, compared to controls. The rate of progressive embryo cleavage in the CC-treated rats were slower than that in controls from Day 3 of pregnancy. Additionally, the percentage of the cleaved embryos recovered from the CC-treated rats remained significantly lower consistently from Day 2 of pregnancy, compared to control regimen. These results demonstrate a possible mechanism of CC-mediated inhibition of ovulatory response in the rats which may include the attenuation or blockade of the endogenous secretion of gonadotropins and also suggest that its detrimental effects observed on oocyte normality and embryonic development may be caused by abnormal follicular steroidogenesis( especially elevated estradiol) preceding fertilization.

  • PDF

The Effectiveness of Sympathetic Skin Response Studies for Patients with Primary Palmar Hyperhidrosis and Who Undergo Thoracic Sympathicotomy (일차성 수부 다한증에서 교감신경절제술 후 교감신경 피부반응 검사의 효용성)

  • Yoon, Jeong-Seob;Sim, Sung-Bo;Rhee, Won-Ihl
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.738-743
    • /
    • 2009
  • Background: There is no standardized tool and parameter that can accurately assess the sympathetic function before and after performing sympathectomy in patients with primary palmar hyperhidrosis. We examined the effective-ness of the sympathetic skin response (SSR) study for documenting the change of sympathetic denervation before and after performing selective thoracic sympathicotomy. Material and Method: We prospectively investigated the SSR from 12 healthy subjects who were diagnosed with primary hyperhidrosis. Each SSR was recorded on the right palm or sole with electrical stimuli applied to the skin at the left wrist and foot and vice versa for the controlateral side. This test was performed before, 2 weeks and 1 year after selective thoracic sympathicotomy. The data was corrected for the onset latency and the amplitude of the SSR (n=24). Result: The mean age of the 12 patients was $24.6{\pm}0.4$ years (range: 19~36) and the gender ratio was 1 : 0.7. The mean values of the preoperative, postoperative 2 weeks and postoperative 1 year onset latency and amplitude of the palmar side (n=24) were $1.46{\pm}0.24$ msec and $6,043{\pm}2,339{\mu}V$, $1.63{\pm}0.42$ msec and $823{\pm}638{\mu}V$, and $1.44{\pm}0.39$ msec and $2,412{\pm}1,546{\mu}V$, respectively. The mean values of the plantar side (n=38) were $1.83{\pm}0.42$ msec and $2,816{\pm}1,694{\mu}V$, $2.16{\pm}0.39$ msec and $1,445{\pm}1,281{\mu}V$ and $1.95{\pm}0.25$ msec and $1,622{\pm}865{\mu}V$, respectively. Among the documented parameters, only the palmar amplitude (p=0.002) showed statistical significance in recording the change of the sympathetic system within the same individual for the pre and postoperative period. Conclusion: The SSR amplitude ratio may be a useful parameter for documenting the efficacy of sympathetic denervation after selective sympathicotomy.

MICROLEAKAGE OF THE EXPERIMENTAL COMPOSITE RESIN WITH THREE COMPONENT PHOTOINITIATOR SYSTEMS (3종 광중합개시제를 함유한 실험용 복합레진의 미세누출도)

  • Kim, Ji-Hoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2009
  • This study was done to determine if there is any difference in microleakage between experimental composite resins, in which various proportions of three component photoinitiators (Camphoroquinone, OPPI, Amine) were included. Four kinds of experimental composite resin were made by mixing 3.2% silanated barium glass (78 wt.%, average size; 1 ${\mu}m$) with each monomer system including variously proportioned photoinitiator systems used for photoinitiating BisGMA/BisEMA/TEGDMA monomer blend (37.5:37.5:25 wt.%). The weight percentage of each component were as follows (in sequence Camphoroquinone, OPPI, Amine): Group A - 0.5%, 0%, 1% / Group B - 2%, 0.2%, 2% / Group C - 0.2%, 1%, 0.2% / Group D - 1%, 1%, 2%. Each composite resin was used as a filling material for round class V cavities (diameter: 2/3 of mesiodistal width; depth: 1.5 mm) made on extracted human premolars and they were polymerized using curing light unit (XL 2500, 3M ESPE) for 40 s with an intensity of 600 mW/$cm^2$. Teeth were thermocycled fivehundred times between $50^{\circ}C$and $550^{\circ}C$for 30s at each temperature. Electrical conductivity (${\mu}A$) was recorded two times (just after thermocycling and after three-month storage in saline solution) by electrochemical method. Microleakage scores of each group according to evaluation time were as follows [Group: at first record / at second record; unit (${\mu}A$)]: A: 3.80 (0.69) / 13.22 (4.48), B: 3.42 (1.33) / 18.84 (5.53), C: 4.18 (2.55) / 28.08 (7.75), D: 4.12 (1.86) / 7.41 (3.41). Just after thermocycling, there was no difference in microleakage between groups, however, group C showed the largest score after three-month storage. Although there seems to be no difference in microleakage between groups just after thermocycling, composite resin with highly concentrated initiation system or classical design (Camphoroquinone and Amine system) would be more desirable for minimizing microleakage after three-month storage.

Effect of Experimental Muscle Fatigue on Muscle Pain and Occlusal Pattern (실험적으로 유발되는 근피로가 근통증 및 교합양상에 미치는 영향)

  • Kim, Jae-Chang;Lim, Hyun-Dae;Kang, Jin-Kyu;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.3
    • /
    • pp.279-294
    • /
    • 2008
  • This study aimed to make an analysis of the occlusion in the state of muscle fatigue produced by excessive mouth opening and clenching during the dental treatment to control the dental pain and to evaluate the sensory nerve in the muscle pain state. Most of the reasons why patients visit the dental office result in pain-either conceivably the dental origin pain or the non-dental origin pain. The dental offices have many therapeutic actions to produce the masticatory muscle fatigue for the treatment. Dental treatment with long minutes of mouth opening can cause some headaches, masticatory muscle pain and mouth opening difficulties. Patients with mastication problems who visits a dental office to alleviate pain run against another unexpected pain with other aspects. This study uses T-scan II system(Tekscan Co., USA) for the evaluation on the occlusal pattern in the experimental muscle fatigue after clenching, opening the mouth excessively and chewing gum. The occlusal contact pattern is analyzed by the contact timing, namely first, intercuspal, maximum and end point of contact. This inspection was performed at frequencies of 2000Hz, 250 Hz and 5 Hz before and after each experimental muscle pain was produced to 24 subjects who had normal occlusion without the orthodontic treatment or a wide range of the prosthesis by using $neurometer^{\circledR}$ CPT/C(Neurotron, Inc. Baltimore, Maryland, USA). The measuring sites were mandibular nerve experimental muscle fatigue respectively. This study could obtain the following results after the assessment of occlusion and sensory nerve of the experimental muscle fatigue. 1. There were the fastest expression after the excessive mouth opening in muscle fatigue and after tooth clenching in muscle pain. In the visual analog scale that records the subjective level, there was the highest scale after the clenching in the muscle fatigue in jumping off the point of pain. 2. Tooth contact time, contact force, relative contact force on the point of the first contact had no difference, and there were decreases in the contact force after the excessive mouth opening on intercuspal position point, after the excessive mouth opening and the gum chewing on the point of the maximum, and in the contact time after all the experimental muscle fatigue state on the point of the end contact. 3. There was no statistic significance in the current perception threshold before and after the experimental muscle fatigue. 4. There was no significant difference in the contact number, the maximal contact number on the point of the first contact, and the contact number after the mouth opening and gum chewing on the point of the intercuspal position and the contact number after the experimental muscle fatigue on the maximum point, and showed significant decreases. In conclusion, it was found that the occlusal pattern can cause the changes on the case of the clinical muscle weakness by intra-external oral events. It was important that the sedulous attention to details is required during dental treatment in case of excessive mouth opening, mastication and clenching.