• Title/Summary/Keyword: 전기저항탐사

Search Result 530, Processing Time 0.02 seconds

Safety Index Evaluation from Resistivity Monitoring Data for a Reservoir Dyke (전기비저항 상시관측에 의한 제체 안전도 지수 산출)

  • Cho, In-Ky;Kang, Hyung-Jae;Lee, Byoung-Ho;Kim, Byoung-Ho;Yi, Sang-Sun;Park, Young-Gyu;Lee, Bo-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.2
    • /
    • pp.155-162
    • /
    • 2006
  • An abnormal seepage flow, which is mainly caused by the piping, is one of the major reasons for embankment dam failure. A leakage detection is therefore a vital part of an embankment dam's monitoring. Resistivity method, which is an efficient tool to detect leakage zones, has been used all over the world for an embankment dam's monitoring. Although the resistivity method gives us very useful information about the leakage problem, there is no more quantitative interpretation than the low resistivity zones in the 2-dimensional resistivity section are regraded simply as the anomalous seepage zones. Recently, resistivity monitoring technique is applied for the detection of leakage zones. However, its interpretation still remains in the stage of presenting the resistivity ratio itself. An increased seepage flow increases a porosity and an increasing porosity decreases the dam's stability. Therefore, the porosity is one of the major factors for an embankment dam's stability. Based on Archie's experimental formula, we try to evaluate a porosity distribution from the resistivity data which is obtained on the dam's crest. We also attempt to represent a procedure to evaluate a safety index of the embankment dam from the resistivity monitoring data.

Analysis of distortion effect of resistivity data due to 3D geometry of fill dam (필댐의 3차원 기하 효과에 따른 전기비저항 왜곡 효과 분석)

  • Oh Seokhoon;Kim Hyoung-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.55-58
    • /
    • 2005
  • Low resistivity zone is observed at the lower part of a CFRD (Concrete Face Rockfill Dam). Generally, CFRD tends not to have any saturated zone within the body, but the result of resistivity survey shows that it is possible for the dam to be saturated under 20m depth with water. The level of reservoir was under 10m from the crest. We suspect that this result may come from the wrong 2D inversion process ignoring the 3D geometry of dams. For the analysis of possibility of distortion by different geometry, we perform the 3D forward modeling for the dam and apply the 2D inversion process. And then we check the point of traditional interpretation of resistivity data. By the analysis, it is found that the result of 2D inversion process of 3D geometry of dams, seems to have deep relation with the reservoir level, and the complex 3D structure hide some internal electrical anomaly of dams from resistivity information.

  • PDF

Application of Geophysical Exploration Methods to Seepage Bone Investigation of Dam Structures (제방누수조사에의 물리탐사기법의 활용(쌍극자배열 전기비저항탐사와 SP탐사를 중심으로))

  • Won Jong-Geun;Song Sung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.240-257
    • /
    • 1999
  • More than 16 percent of the total 18,032 reservoirs over the country were reported to have leakage problems and need to be improved. Recently, a great deal of progress was made in geophysical survey techniques, particularly in electrical resistivity, and the techniques are used for variety of Purposes in groundwater and dam management due to its economical advantages. This document describes the re-evaluation of existing resistivity data including newly surveyed data, mapping of modeled value in 2-D analysis to locate seepage pathways, This contains also discussion results of more than eighteen years of professional experiences in the field of dam efficiency improvement. In comparison of surface resistivity data with several soil analysis data in laboratory, it is evident that the surface resistivity value shows a qualitative proportionality with the sand contents of the filling materials in earth dam. The result from the study also indicates that the SP method in subsurface investigation is effective to detect seepage in earth filled dam as well as piping through rock/earthfill dike.

  • PDF

A Study on the DC Resistivity Method to Image the Underground Structure Beneath River or Lake Bottom (하저 지반특성 규명을 위한 수상 전기비저항 탐사에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Choi Seong-Jun;Lee Seoung Kon;Son Jeong-Sul;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.223-235
    • /
    • 2002
  • Since weak Bones or geological lineaments are likely to be eroded, there may develop weak Bones beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. DC resistivity method, however, has seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of a case history, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing them at the water bottom, because the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the DC resistivity method can provide fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio (S/N ratio) data as well as the high resolving power. Some of the modified electrode arrays can provide the data having reasonably high S/N ratio and need not to install remote electrode(s), and thus, they may be suitable to the resistivity survey at the water-covered area.

Geophysical exploration for the Site Charcteristics of Iljumun Gate in Hwanseongsa Temple (지구물리탐사를 이용한 경산시 환성사 일주문 지반조사)

  • Kim, Ki-Hyun;Suh, Man-Cheol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.131-136
    • /
    • 2008
  • We performed a non-destructive geophysical survey such as an elastic wave survey, electric specific resistance survey, plate loading test, etc. in order to grasp the structure and status of the ground around the pillar gate and to provide the directions and design data for preservation and maintenance during reconstruction. The result of electric specific resistance survey shows 50-1300 ohm-m range of general electric specific resistance distribution. Besides, the positions around 1m south of stone pillars, between stone pillar No.3 and 4, and 1m north of stone pillar No.2 and 3 show abnormality of relatively lower electric specific resistance than their surroundings. The abnormality of low electric specific resistance appearing between stone pillar No.3 and 4 shows consistency with the abnormal section appearing from the result of elastic wave reflection survey. The result of a plate loading test shows that allowable bearing force is over $10.70tf/m^2$, and the settlement amount at this time was calculated as 19.635mm. The design load during reconstruction of pillar gates was calculated as $16.37t/m^2$ by applying assumption values, which is far more than the allowable bearing force, so it is judged that a measure to strengthen the foundation ground is necessary.

  • PDF

An Electrical Resistivity Monitoring in Embankment (제방에서의 전기비저항 모니터링)

  • Ahn, Taegyu;Ko, Chihye;Jeong, Yujeong;Lee, Heuisoon;Song, Sung-Ho;Yong, Hwan-Ho
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.59-67
    • /
    • 2015
  • An electrical resistivity survey is widely conducted for the safety management of embankment. In this study we investigated how a tidal variation affects the interpretation of electrical resistivity monitoring data of the embankment located in west coast. We monitored the variation of electrical resistivity on the coastal embankment where there was a high tidal variation for 3 days in every 3 hours. Electrical resistivity monitoring data showed a variation of resistivity distribution in specific area according to the time, which demonstrated some correlation with a tidal height variation. Therefore, we highly recommend that a tidal effect be considered when electrical resistivity survey is conducted on the embankment where there is a high tidal variation. For further study, we need a long term electrical resistivity monitoring and analyzing on tidal variation.

공주 능치지역 천부 지하구조에 대한 지구물리학적 연구

  • Kim, Gi-Hyeon;Seo, Man-Cheol
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.2
    • /
    • pp.103-111
    • /
    • 2001
  • Geophysical survey was carried out to derive some information on the existence of near-surface anomalous body at Reung-Chi area in Kongju. Resistivity, seismic, magnetic and gravity method were applied. Geophysical survey that was applied was the electrical resistivity survey, seismic survey, magnetic survey, gravity survey. These surveys are analyzed to provide data of high resolution. As a result of analysis of resistivity survey, anomalies showing high resistivity anomaly than around appeared, and the one showing M-shape out of those explains the possibility that underground common or other underground structure or geographical anomalous zone could exist in the underground. As a result of analysis of seismic survey, it is clear that the low velocity layer is spread as far as the bottom of the underground. It is possible to presume that it is a phenomenon appearing while going through the underground space where it is lying in the underground. Area that shows unusual situation in interpretation of data on seismic waves are included into the area that once showed resistivity anomaly, the results of both seismic surveys come in accord. As a result of magnetic survey, a circle-shape of twin magnetic fields in the area where abnormalities are shown between electrical resistivity survey and seismic survey is appeared. Given the area of gravity survey, abnormalities whose density is different from the one around the bottom of the underground. As a result of analogizing the data of underground of the subsurface based on analysis of data from each survey, it was interpreted that anomalous zone exists commonly in the research areas.

  • PDF

A Geophysical Survey of an Iron Mine Site (철광산 지역에서의 물리탐사 기술 적용 연구)

  • Kim, Kiyeon;Oh, Seokhoon
    • Journal of the Korean earth science society
    • /
    • v.34 no.6
    • /
    • pp.575-587
    • /
    • 2013
  • DC electrical and electromagnetic survey was applied to evaluate the reserve of an iron mine site. We analyzed the borehole cores and the cores sampled from outcrops in order to decide which geophysical method was efficient for the evaluation of iron mine site and to understand the geological setting around the target area. Based on the core tests for specific weight, density, porosity, resistivity and P-wave velocity, showing that the magnetite could be distinguishable by the electrical property, we decided to conduct the electrical survey to investigate the irone mine site. According to previous studies, the DC electrical survey was known to have various arrays with high resolutions effective to the survey of the iron mine site. However it was also known that the skin depth is too shallow to grasp the deep structure of iron mine. To compensate the weakness of the DC electrical method, we applied the MagnetoTelluric (MT) survey. In addition, a Controlled Source MT (CSMT) method was also applied to make up the shortcoming of MT method which is weak for shallow targets. From the DC electrical and MT survey, we found a new low resistivity zone, which is believed to be a magnetite reserve beneath the old abandoned mine. Therefore, this study was confirmed for additional utility value.

3-D Resistivity Imaing of a Large Scale Tumulus (대형 고분에서의 3차원 전기비저항 탐사)

  • Oh, Hyun-Dok;Yi, Myeong-Jong;Kim, Jung-Ho;Shin, Jong-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • To test the applicability of resistivity survey methods for the archaeological prospection of a large-scale tumulus, a three-dimensional resistivity survey was conducted at the $3^{rd}$ tumulus at Bokam-ri, in Naju city, South Korea. Since accurate topographic relief of the tumulus and electrode locations are required to obtain a high resolution image of the subsurface, electrodes were installed after making grids by threads, which is commonly used in the archaeological investigation. In the data acquisition, data were measured using a 2 m electrode spacing with the line spacing of 1 m and each survey line was shifted 1 m to form an effective grid of 1 m ${\times}$ 1 m. Though the 3-D inversion of data, we could obtain the 3-D image of the tumulus, where we could identify the brilliant signature of buried tombs made of stones. The results were compared with the previous excavation results and we could convince that a 3-D resistivity imaging method is very useful to investigate a large-scale tumulus.

Correlation interpretation for surface-geophysical exploration data-Chojeong Area, Chungbuk (지표물리탐사 자료의 상관해석-충북 초정지역)

  • Gwon, Il Ryong;Kim, Ji Su;Kim, Gyeong Ho
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.1
    • /
    • pp.75-88
    • /
    • 1999
  • A recent major subject of geophysical exploration is research into 3-D subsurface imaging with a composite information from the various geophysical data. In an attempt to interpret Schlumberger sounding data for the study area in 2-D and 3-D view, resistivity imaging was firstly performed and then pseudo-3-D resistivity volume was reconstructed by interpolating several 1-D resistivity plots. Electrical resistivity discontinuities such as fracture zone were successfully clarified in pseudo-3-D resistivity volume. The low resistivity zone mainly associated with fracture zone appears to develop down to granitic basement in the central part of the study area. Seismic velocity near the lineament is estimated to be approximately as small as 3,000 m/s, and weathering-layer for the southeastern part is interpreted to be deeper than for the northwestern part. Geophysical attributes such as electrical resistivity, seismic velocity, radioactivity for the Chojeong Area were analysed by utilizing a GIS software Arc/Info. The major fault boundaries and fracture zones were resolved through image enhancement of composite section (electrical resistivity and seismic refraction data) and were interpreted to develop in the southeastern part of the area, as characterized by low electrical resistivity and low seismic velocity. However, radioactivity attribute was found to be less sensitive to geological discontinuities, compared to resistivity and seismic velocity attributes.

  • PDF