• Title/Summary/Keyword: 전기저항측정법

Search Result 7, Processing Time 0.026 seconds

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

Measurement of Electrical Resistance Method in Characterizing the Slip ratio of Carbon fiber/Matrix at the Interface (전기저항 측정법을 이용한 탄소섬유/기지 간 계면에서의 섬유 미끌림 정도 측정방법)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Park, Joung-Man
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.205-210
    • /
    • 2012
  • The single carbon fiber tensile test was performed with electrical resistance measurement. Tensile property of single carbon fiber which accompanied by the relationship between the electric resistance and the strain was investigated. Since the collected data showed a linear relationship between them, the coefficient of fiber slip ratio (FSR) was obtained by computation. The fragmentation specimen (FS) was tested under tensile loading, and the single carbon fiber broke first due to the stress transferring form matrix to reinforcing fiber. The stress distribution of carbon fiber could be observed via the electrical resistance change. Slipping between carbon fiber and matrix was predicted based on the fragmentation test results, and the FSR was used to evaluate interfacial adhesion comparatively. The large FSR indicated poor interfacial bonding. Work of adhesion between carbon fiber and matrix was measured to verify the FSR method, and two results exhibited a consistent conclusion.

Interfacial Evaluation and Microfailure Sensing of Nanocomposites by Electrical Resistance Measurements and Wettability (전기저항측정법 및 젖음성을 이용한 나노복합재료의 미세파손 감지능 및 계면물성 평가)

  • Park, Joung-Man;Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Ha-Seung
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.138-144
    • /
    • 2017
  • Damage sensing of polymer composite films consisting of poly(dicyclopentadiene) p-DCPD and carbon nanotube (CNT) was studied experimentally. Only up to 1st ring-opening polymerization occurred with the addition of CNT, which made the modified film electrically conductive, while interfering with polymerization. The interfacial adhesion of composite films with varying CNT concentration was evaluated by measuring the wettability using the static contact angle method. 0.5 wt% CNT/p-DCPD was determined to be the optimal condition via electrical dispersion method and tensile test. Dynamic fatigue test was conducted to evaluate the durability of the films by measuring the change in electrical resistance. For the initial three cycles, the change in electrical resistance pattern was similar to the tensile stress-strain curve. The CNT/p-DCPD film was attached to an epoxy matrix to demonstrate its utilization as a sensor for fracture behavior. At the onset of epoxy fracture, electrical resistance showed a drastic increase, which indicated adhesive fracture between sensor and matrix. It leads to prediction of crack and fracture of matrix.

Surface control and durability evaluation of CNT and ITO coated PET transparent electrode with different dry conditions (건조 상태에 따른 CNT 및 ITO로 코팅된 PET 투명전극의 표면 조절 및 내구성 평가)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Park, Joung-Man
    • Composites Research
    • /
    • v.24 no.5
    • /
    • pp.17-22
    • /
    • 2011
  • Recently transparent electrodes using carbon nanotube (CNT) have been studied actively to replace conventional ITO. In this work, CNT or ITO coated poly(ethylene terephthalate) (PET) were prepared by controlling the surfaces since the cohesion degree depends upon drying conditions. As transparent electrode application, 3 drying temperatures were set as 20, 80, and $120^{\circ}C$ to produce the change of surface properties. Interfacial durability and electrical properties of prepared transparent electrodes were evaluated by electrical resistance measurement. Surface change with changing drying temperature was observed by FE-SEM, whereas the transparency change was measured by UV-spectroscopy. The electronic properties of nanoparticle coated surface were evaluated using cyclic voltametry method upon the surface change with controlled drying temperature. Durability of CNT coated surfaces was better than ITO coated ease. As drying temperature increased, better coated surface was prepared due to improved cohesion among nanoparticles, which resulted in increased electrical properties.

The Hydrogen Absorption Kinetics in very thin Pd film(α phase) (α 상 Pd박막의 수소 흡수 동역학)

  • Cho, Young-sin;Lee, Jong-suk;Kim, Chang-won
    • Journal of Hydrogen and New Energy
    • /
    • v.9 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • 4-probe resistivity measurement technique was used to study kinetics of hydrogen absorption on Pd film ($180{\AA}$ thick) in the ${\alpha}$ phase. Hydrogen gas was introduced to the activated Pd film. For very low hydrogen concentration the following rate law is valid in ${\alpha}$ phase very thin Pd film $$v=k\frac{1}{1+KX{_H}}PH{_2}-k^{\prime}\frac{KX{_H}{^2}}{1+KX{_H}}$$ which is similar to that of bulk. The activation energy of the forward reaction is 4.6kcal/mol H and of the backward reaction 8.4kcal/mol H, which yields the reaction enthalpy -3.8kcal/mol H in the temperature range between 25 and $40^{\circ}C$. The values of activation and enthalpy of thin film are rather smaller than that of bulk sample. This may be due to surface area difference between bulk and film.

  • PDF

The development of non-contact soil moisture sensors using Rayleigh waves and a fully convolutional network (레일리파와 딥러닝를 활용한 비접촉식 토양수분센서 개발)

  • Seoungmin Lee;Dong Kook Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.223-223
    • /
    • 2023
  • 토양수분은 지표면과 지하 영역 사이에 존재하는 수분 및 열에너지의 분배를 제어하거나, 토양 영양분, 식물 성장 및 미생물 활동과 같은 다양한 환경 과정에 영향을 미치는 핵심 구성요소이다. 토양수분은 생태수문학 및 생지화학적 역학, 저수지 관리, 가뭄 및 홍수의 경고, 토양 수분 변화에 따른 작물 수확량 등을 이해하는 데 매우 중요한 역할을 한다. 따라서, 토양 수분의 정확한 측정은 필수적이며, 이러한 필요성에 따라 중력 측정법, 장력 측정법, 전기 저항법 및 시간-주파수 영역반사측정법 등의 다양한 측정 방법들이 다년간 개발되어 사용되었다. 다만, 앞선 방법들은 철저한 실험을 통해 높은 정확성을 확보하였지만, 토양 교란이 발생하는 단점이 존재하며 실험 현장 토양의 물리적, 생물학적, 그리고 화학적 특성의 보존은 매우 어려운 한계점을 가지고 있다. 따라서, 이러한 단점을 극복하기 위해, 본 연구에서는 레일리파를 이용한 비접촉식 비교란 토양수분 센서 개발을 목표로 한다. 모래, 실트, 점토와 같은 세 가지 특징적인 토양 유형에 따른 파동을 측정하고, 측정된 파동으로부터 토양 수분을 추정하기 위해 기존에 개발된 시간-주파수 방법을 활용하여 토양수분을 함께 측정하였다. 비접촉 파동신호를 토양수분으로 변환하기 위하여, fully convolutional network을 개발하였다. 개발한 모델의 결과 검증은 RMSE(Root Mean Square Error)를 활용하여 검증하였으며, 모래, 실트, 점토에서 각각 0.0131, 0.0021, 0.0034 m3 m-3으로 상대적으로 높은 정확성을 보였다. 즉, 본 연구에서 제시한 누출 레일리파를 사용한 비교란-비접촉 토양수분 측정 방법으로, 토양을 교란하지 않고 토양수분을 측정 할 수 있는 높은 가능성을 제시하였다.

  • PDF

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF