Development of an Input Impedance Evaluation of the AC-DC Transfer Standard for Low Level AC Voltage Standard (교류 저전압 표준용 교류-직류 변환기의 입력임피던스 평가기술 개발)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kim, Myung-Soo;Kim, Han-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.229-234
    • /
    • 2008
  • An AC-DC transfer standard(TS) is used for the AC voltage standard in the range of 2 mV to 1000 V below 1 MHz. Micro-potentiometer(${\mu}Pot$) is used to evaluate the ac-dc transfer difference(ADD) of the TS below 200 mV range. The ADD of the TS were changed by the loading effect caused from the input impedance change of the TS depend on frequency. An input impedance evaluation technique of the TS using ${\mu}Pot$ has been developed.

Starting Performance Analysis for Large Induction Motor Pump System Under the Circumstance of Long Distance Distribution Line (장거리 배전선로에서 펌프구동용 대용량 전동기의 기동특성 분석 연구)

  • Lee, Nam-Hyung;Lee, Kwang-Ho;Kim, Hyun-Il;Jang, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.311-312
    • /
    • 2008
  • 장거리 배전선로를 이용하여 대용량의 모터펌프를 기동할 경우 상대적으로 큰 임피던스 전압강하에 따른 모터의 기동불능 및 기동지연 등의 현상이 발생할 가능성이 있다. 본 논문에서는 K-water D 취수장에서 운영중인 2200kW 모터 기동시 발생하는 이상 현상에 대한 원인을 분석하고 이에 대한 해결책을 제시하였다. 특히 장거리 배전선로 환경하에서의 모터 기동시 문제점에 대한 해결책을 제시하기 위해 PTW를 이용하여 시뮬레이션하였다.

  • PDF

A study of Hybrid Fault Current Limiter Connected to Power Grid by Using Phase Locked Loop (위상동기회로(PLL)를 이용한 하이브리드 방식의 계통적용 한류기에 관한 연구)

  • Sung, Byung-Chul;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.476-477
    • /
    • 2008
  • 초전도 소자만을 이용한 한류기는 여러 가지 해결해야할 비용적, 기술적 문제를 안고 있다. 이런 문제들에 대한 해결과 동시에 초전도 한류기의 실용화를 위해 하이브리드 방식의 한류기가 고안되었으며 이는 초전도 소자만을 이용한 한류기가 갖고 있는 많은 문제점들을 해결할 수 있다고 판단되는 한류 방식이다. 본 논문은 기존의 하이브리드 방식의 한류기를 바탕으로 하여 Phase Locked Loop(PLL, 위상동기회로)를 이용한 하이브리드 방식의 초전도 한류기를 제시하였다. 일정한 선로 임피던스를 갖는 계통에서 사고가 발생할 경우 고장전류와 정상 상태의 전류 사이에 위상차가 발생하게 되는데, 이 위상차를 PLL의 위상 검출 능력을 통해 검출함으로써 한류기로서 동작할 수 있도록 하였다. 제시된 하이브리드 한류기의 성능은 PSCAD/EMTDC를 이용한 시뮬레이션을 통해 일기무한모선 시스템에 대한 적용을 통해 평가하였다.

  • PDF

A Information on Developing the web based integrated Protection Assistance System (Web 기반 계통보호 통합지원 시스템(i-PAS) 개발)

  • Hong, Jung-Woo;Lee, Chong-Hak;Lee, Myeong-Hee;Woo, Doug-Je
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.67-68
    • /
    • 2008
  • 본 논문은 기존 계통보호 전산프로그램의 프로그램 성능을 개선하고 활용도를 제고하기 위해 개발된 계통보호 통합지원 시스템(i-PAS)을 설명한다. 계통보호를 위한 전산시스템은 1997년 연구개발을 시작으로 추진되었다. i-PAS는 Web 기반의 시스템으로 사용자의 설치 환경을 단순화하였고 신규 도입된 정정모듈을 추가하면서 가상정정이 가능해져 다양한 정정 모의를 실현하였다. 또한 웹에서 관리한 현황을 이용한 자동 통계기능을 추가하여 자료 처리에 소요되는 시간을 단축하였다. 임피던스 프로그램은 입력 자료를 조정하여 실측치에 가까운 모델링이 가능해졌다. 향후에는 계전기 파일을 직접 출력하여 수작업 입력시 발생할 수 있는 인적실수를 방지하고 컴퓨터가 계통상황에 따라 정정을 모의하고 변동되는 부분을 관리자에게 통보하는 자동 시스템으로 발전시킬 필요가 있다.

  • PDF

Impedance variation analysis of magnetic coupling-type superconducting fault current limiter with the series connection of two coils (두 코일의 직렬연결을 갖는 자기결합형 초전도 전류제한기의 임피던스 변화분석)

  • Kim, Kyung-Tac;Kim, Yun-Ho;Lim, Sung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2237-2238
    • /
    • 2008
  • 고장전류의 문제점을 파악하고, 두 코일의 직렬연결을 갖는 자기결합형 초전도 전류제한기의 필요성에 대해서 알아보았다. 그리고 두 코일의 직렬연결을 갖는 자기결합형 초전도 전류 제한기의 구성과, 실험장치의 회로구성에 대하여 나타내었다. 실험에서는 결선방향의 변화와 부하저항 값의 변화에 따른 사고전류와 초전도 소자의 값을 측정하여 분석하였다. 또한, 사고 제거 후 제한기의 복귀시간 변화의 값을 측정하고 그에 따른 분석 후 발전 가능성을 예측해보았다.

  • PDF

Frequency Characteristics of Grounding Impedances of the Deeply-driven Ground Rods (심매설 접지전극에 대한 접지임피던스의 주파수특성)

  • Kang, Sung-Man;Kim, Tae-Ki;Kim, Han-Soo;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1348-1349
    • /
    • 2008
  • Grounding impedance depends on the frequency of current flowing into a grounding system. Especially, the lightning gives a broad frequency spectrum from low frequency up to 1 MHz. So the grounding impedance related to high frequency current like lightning should be measured with high frequency source. In this paper, we described the grounding impedances of deeply-driven ground rods of 10 $\sim$ 48 m long with respect to the frequency of injected currents. For the experiments, we used the wideband power amplifier which can produce sinusoidal voltages with the frequency ranges of DC $\sim$ 250 MHz. As a result, the longer the ground rod is, the lower the ground resistance is. However the grounding impedance of deeply-driven ground rod in the range of higher frequency is significantly increased. As a consequence, it is important to evaluate the high frequency performance of grounding systems for lightning protection.

  • PDF

Research of Electric Leakage Characteristic by Magnetic Field (자계를 이용한 누전특성조사)

  • Kim, Tag-Yong;Oh, Yong-Chul;Jeong, Han-Seok;Yun, Su-Jin;Yoo, Jae-Sik;Choi, Myeong-Ho;Ji, Yong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2108-2109
    • /
    • 2008
  • 매년 증가하고 있는 누전사고에 대한 대책수립을 위해 누전검출장치 및 누전조사작업을 시행하고 있지만, 대부분 전압변화 및 영상전류 및 z임피던스에 의한 계측이 주를 이루고 있다. 본 논문에서는 누전지역에서의 누설전류에 자속밀도 분포를 조사함으로 손쉬운 누전검출장비 개발 및 비접촉에 의한 누전검출장비 개발과 누전환경에서의 기초 연구자료를 제공하고자 정상선로에서의 자속밀도 분포 및 전압변화에 따른 자속밀도 분포를 조사하였다. 그 결과 정상도선에서는 거리변화에 따른 자속밀도가 감소하였으며, 이에 반해 침수된 누전지역에서는 자속밀도변화가 거의 없음을 확인할 수 있었으며, 전압 증가에 따라 누전지역의 전류값이 정상상태보다 더 크게 변화하는 것을 확인할 수 있었다.

  • PDF

Diagnosis of State of Health for Industrial Lead-Acid Battery (산업용 납축전지의 건전상태 진단 연구)

  • Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Lee, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2202-2203
    • /
    • 2008
  • 축전지는 비상용 전원으로 사회 많은 분야에서 다양하게 사용되며, 유사시 예비전원으로 그 중요성이 부각되고 있다. 이러한 경우에 사용가능한 축전지를 선별하고, 그 상태를 체크하는 것은 무엇보다도 중요하다. 본 논문에서는 축전지의 잔존수명을 보다 짧은 시간에 효과적으로 분석할 수 있는 순간방전시험을 이용하여 축전지의 잔존수명을 판단하고자 하였다. 실험결과 순간방전 시험을 통한 mode 2에서의 임피던스 값과 실부하 방전시험 결과가 서로 일치함을 알 수 있었으며, 이를 통해 축전지의 잔존수명을 파악할 수 있을 것으로 사료된다. 본 논문은 추후에 계속되는 축전지 잔존수명 분석을 위한 기초 자료로 활용될 수 있을 것이다.

  • PDF

Optimum electrode selection for measuring the abdominal pressure using bio-impedance method (비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정)

  • An, Yang-Su;Kim, Keo-Sik;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

Study of AC Filter Design considering Harmonic Mitigation for HVDC System (고조파 저감을 고려한 HVDC System용 AC 필터 설계 방법에 관한 연구)

  • Chyun, Yi-Kyung;Kim, Hyun;Choi, Yong-Kil;Lee, Uk-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.209-210
    • /
    • 2015
  • High Voltage Direct Current(HVDC) System용 AC 필터는 특정 고조파 영역에서 낮은 임피던스를 제공하여 AC 계통으로 유입되는 고조파를 억제시킴과 동시에 무효전력의 공급원으로서의 역할도 수행한다. 대부분의 전류형 HVDC System은 12개의 Pulse로 동작하기 때문에 $12n{\pm}1$차의 특성고조파를 발생시키는데 HVDC System에서는 이러한 특성고조파들을 저감시키기 위한 Harmonic AC Filter가 주로 사용된다. 본 논문에서는 HVDC System용 AC 필터를 설계할 때 고조파 저감을 고려한 다목적 최적화 알고리즘을 제시함으로써, 향후 시스템의 안전성과 효율성 측면에서 기여할 수 있는 실제 HVDC System용 AC 필터 설계 적용에 큰 도움이 될 것으로 기대된다.

  • PDF