• Title/Summary/Keyword: 전기신호측정

Search Result 921, Processing Time 0.033 seconds

A Study on Development of the High-Power Low-Loss Waveguide Circulator for Ka-band Millimeter-Wave Seeker (밀리미터파대역(Ka-대역)탐색기용 고 전력 저 손실 도파관 순환기 개발에 관한 연구)

  • Jung, Chae-Hyun;Han, Sung-Min;Baek, Jong-Gyun;Lee, Kook-Joo;Park, Chang-Hyun;Kwon, Jun-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.83-88
    • /
    • 2017
  • In this paper, a 3-port waveguide circulator of Ka-band millimeter-wave for isolation between transmit channel and receive channel at high power transmit mode is designed and fabricated for the seeker of the guided missile and circulator performance is verified through the S-parameter, high power and operation temperature test. At the configuration design, interface design between a seeker antenna and the circulator is considered and half-height of standard waveguide is applied for minimum and light weight body. The shape of permanent magnet and ferrite is optimized by simulation and tuning dielectrics at each port are placed for the best performance. In Fc(center frequency)${\pm}1000MHz$, designed waveguide circulator has below -20 dB return loss, below 0.5 dB insertion loss and below -23 dB isolation. It is found that circulator characteristics is similar to design results.

Growth and characterization of CdTe single crystals by vertical Bridgman method (수직 Bridgman법에 의한 CdTe 단결정의 성장과 특성)

  • 정용길;신호덕;엄영호;박효열;진광수
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.2
    • /
    • pp.220-228
    • /
    • 1996
  • CdTe single crystals were grown by vertical Bridgman method using double furnace with two siliconit heating elements. When the peak temperature of the upper furnace was fixed at $1150^{\circ}C$ and that of the lower furnace was $800^{\circ}C$, the temperature gradient was about $22.5^{\circ}C$/cm. The lattice constant $a_0$ was $6.482\AA$ from the X-ray diffraction and the band gap energy obtained from the optical absorption experiment at room temperature was 1.478 eV. PL spectrum showed that the bound exciton emission peak was resolved into ($A^0,X$) (1.5902, 1.5887 eV), ($h\;D^0$) (1.5918 eV) and ($D^0,X$ (1.5928, 1.5932 eV), and we have also calculated binding energy and ionization energy of the neutral donor and acceptor.

  • PDF

Construction and Performance of Magnetically Shielded Room for Biomagnetic Applications (생체자기계측을 위한 자기차폐실의 설치 및 특성)

  • 이용호;권혁찬;김진목;임청무;이상길;박용기;박종철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.264-271
    • /
    • 1996
  • A magnetically shielded room has been constructed for biomagnetic applications. The room has internal dimensions of $2\;m(length){\times}2\;m(width){\times}2.5\;m(height)$ and it consists of high permeability Mumetal and high conductivity alummum, utilizing ferromagnetic shielding and eddy current shielding. The de shielding factor around the center of the room is above 60 dB, and the ac shielding factors at 1 and 10 Hz are larger than 60 and 80 dB, respectively. The internal magnetic field noise at 1 Hz is $500\;fT/{\sqrt}Hz$ and at 10 Hz is $100\;fT/{\sqrt}Hz$, and the field gradient noise at 1 Hz is below $7\;fT/cm{\sqrt}Hz$. Successful measurements of cardiomagnetic fields usmg SQUID magnetometer and neuromagnetic fields using SQUID gradiometer have been done.

  • PDF

Preparation of Hydrogels Containing Polypyrrole@lignin Hybrids and Application in Sensors (전도성 고분자/리그닌 복합소재를 함유한 하이드로젤의 제조 및 센서 응용)

  • Park, Sun Young;Park, Soyeon;Kim, Hye Jun;Im, Youngsoon;Bae, Joonwon
    • Applied Chemistry for Engineering
    • /
    • v.31 no.4
    • /
    • pp.411-415
    • /
    • 2020
  • In this article, the preparation of hydrogels containing conducting polymer@lignin hybrids and their application to sensing materials were demonstrated using diverse techniques. A conducting polymer, polypyrrole (PPy) was polymerized on the surface of lignin and successful formation was analyzed with Fourier-transform infrared spectroscopy and scanning electron microscopy. Subsequently, PPy@lignin hybrids were mixed with a hydrogel matrix to obtain a conductive hydrogel. The feasibility of using the hydrogel as a sensing material was shown by obtaining reasonable sensing signals using various electrical measurements when adding solvents and solutions to the sensor system. The significance of sensor signals was confirmed with complementary experiments. This study shows that the hydrogel containing the PPy@lignin could be used for sensor applications.

Dispersive FDTD Modeling of Human Body with High Accuracy and Efficiency (정확하고 효율적인 인체 FDTD 분산 모델링)

  • Ha, Sang-Gyu;Cho, Jea-Hoon;Kim, Hyeong-Dong;Choi, Jae-Hoon;Jung, Kyung-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.108-114
    • /
    • 2012
  • We propose a dispersive finite-difference time domain(FDTD) algorithm suitable for the electromagnetic analysis of the human body. In this work, the dispersion relation of the human body is modeled by a quadratic complex rational function(QCRF), which leads to an accurate and efficient FDTD algorithm. Coefficients(involved in QCRF) for various human tissues are extracted by applying a weighted least square method(WLSM), referred to as the complex-curve fitting technique. We also presents the FDTD formulation for the QCRF-based dispersive model in detail. The QCRFbased dispersive model is significantly accurate and its FDTD implementation is more efficient than the counterpart of the Cole-Cole model. Numerical examples are used to show the validity of the proposed FDTD algorithm.

Quadruple Polarized Antenna System with a Reconfigurable Feeding Network (재구성 급전 구조를 갖는 4중 편파 안테나 시스템)

  • Lee, Wang-Sang;Lee, Dong-Jin;Tae, Hyun-Sung;Park, Donghoon;Oh, Kyoung-Sub;Lee, Moon-Que;Yu, Jong-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2013
  • In this paper, quadruple polarized antenna system with a reconfigurable feeding network is presented. The proposed antenna system consists of the reconfigurable feeding network for fourth polarization such as vertical/horizontal linear polarization and right-handed/left-handed circular polarizations or 45 degree tilted vertical/horizontal linear polarization and patch antenna to receive the signals with various polarizations. In order to receive a signal in any direction, the proposed antenna is designed by electrical switches for reconfigurable polarization. The insertion loss of the designed feeding network in the proposed antenna system is approximately 1.2 dB. The measured 3 dB axial bandwidth and gain of the proposed antenna are about 2 % and 4 dBi(c).

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

The Study on the Realtime Evaluation of NH3 Absorption Efficiency Using Chemical Gas Sensor (가스센서를 활용한 암모니아 가스의 실시간 흡수 효율 평가에 관한 연구)

  • Lim, Jung-Jin;Kim, Han-Soo;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.4
    • /
    • pp.233-239
    • /
    • 2013
  • This study was carried out to develop the realtime evaluation system of $NH_3$ absorption efficiency with gas sensors which were installed on the inlet and outlet of lab-scale scrubber system. The $NH_3$ absorption amount, calculated by sensor outcomes for 3 hr, 6 hr, and 12 hr of absorption process, was compared with the results analysed by Indo-phenol method for the absorption solution. Even though the difference between two methods was about 20%, the correlation coefficient between the two results was very high, more than 0.99. In addition, we could find very good correlation between pH, absorption amount and reaction time. Also we could find out the breakthrough time in the middle of absorption process. With more diverse experiment in the future, we can make gas sensor system for the realtime evaluation of the odor and/or air pollution treatment efficiency.

DAQ System을 활용한 초지기 맥동현상의 개선

  • 이영준;김도환;서동준;고두석;이복진
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.04a
    • /
    • pp.81-81
    • /
    • 2001
  • 초지 공정은 wire, roll, pump등의 회전체로 이루어진 공정이 거의 대부분이기 때문에 주기적으로 변동하는 성분들이 많고, QCS(Quality Control System) 및 DCS(Distributed Co n ntrol System)상에 서 의 자동 Control Logic에 의 한 불안정 (Fluctuation)요소도 내 재 되 어 있 어 이에 대한 분석이 필요하다. 이러한 주기적인 변동은 제품의 여러 물성(평량, 두께, 광택 도등) 에 영향을 미치게 되어 품질의 균일성이나 프로파일에 영향을 미치게 된다. 따라서 공정상이나 품질에서 주기적으로 변동하는 성분을 추출하여 공정 각 성분과 연관을 시키변 품질에 나타나는 주기적 성분의 요인이 어느 부분에서 기인하는 지를 직접적으로 찾아낼 수 있고 이의 개선을 통해 품질의 균일성 및 프로파일 향상을 꾀할 수 있다. 본 연구에서는 Air padded type 헤드박스 초지기에서 DAQ(Data Acquisition) System 을 이용하여 각 공정별로 MD(Machine Direction)방향으로의 변동을 측정하고 제품의 물성 변동과 비교하였다. DAQ System은 각 공정상의 전기적 신호를 높은 주파수 영역까지 다채널로 동시에 받 아 들일 수 있는 장치로 이 시스템을 활용하여 공정상의 Machine chest 농도, Stock box 유량 및 레벨, Fan pump RPM, Cleaner압력, Screen압력, H!B압력 및 레벨, Silo level등 공 정요소의 변동상태와 상호영향을 분석하였다. 이러한 공정 각 요소의 변동과 MD 방향의 제품 물성 값(Tapio, Paper Variation Analyzer에 대한 비교 분석결과 제품 평량에서 주기적인 변동성분을 확인할 수 있었고 이중 큰 비 중을 차지하는 것이 fνB 레벨 변동주기와 일치하는 것을 찾아낼 수 있었다. 이에 근거하여 D DCS system의 control 요소인 튜닝 parameter(P,I 값)들을 미 세 조정 하여 제 품의 MD방향 평량 변동 진폭을 기존 수준의 30% 수준으로 감소시킬 수 있었다. 그 결과 COV(표준편차/ 평량)값을 0.8-1.2%에서 0.6-0.8%수준으로 낮출 수 있었고 이에 따라 CD (Cross Direction) 방향의 제품 Profile도 함께 개선되는 효과를 거둘 수 있었다.

  • PDF

Inoformation Compression of Myoelectric M-wave Evoked by Electrical Stimulus using AR Model (AR 모델을 이용한 전기자극에 대한 근신호 M -wave의 정보압축)

  • 김덕영;박종환;김성환
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.307-314
    • /
    • 1999
  • This paper describes an informatlon compression of electrically evoked myoelectric signal, M-wave. This wave shows a direct response m lato-response of nerve conductlQn study and has a characteristic with finite time support. M-wave is a useful factor for investing neurodi~ease and is often desirable to have a compact description of its shape and time evolution. The aim of this paper is to show that the AR modeling IS a effective method for compressing an information of M-wave. First, AR model parameters of real M-wave are estimated. And then. they are verified by approximatmg a M-wave using estimated AR parameters and by comparing to other melhod, Hermite tlansform[4]. To concretely evaluate the proposed method, the NMSE(normalized mean square error) of approximation curves are compared. As a result, AR modeling is effective for M-wave assessment because of its capability for the information compression.

  • PDF