• Title/Summary/Keyword: 전기신호측정

Search Result 918, Processing Time 0.032 seconds

An Experimental Study on a Solenoid Eddy Current Sensor to inspect Deteriorations in Overhead Distribution Lines (가공 배전선의 열화를 검출하기 위한 솔레노이드 와전류 센서의 실험적 연구)

  • 김성덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 1999
  • This paper deals with an experirrental study of a nondestructive testing system using a solenoid eddy currnet sensor to inspect deteriorations in overhead distribution lines, such as broken wires, severe local corrosion or zinc loss. Corrosion rrechanisrn for ACSR and ACSR-OC is discussed and characteristics for a solenoid sensor to insprt the georretrical pararreters of the coil and testing materials impOOance are briefly analyzed. A measurement system having a constant current source, a signal processing unit and a motor driver is impIemented. This instrument has such capabilities as detecting the sensor output and estimating dinHlsions of the testing conductors, continuously. As a result, it was shown that the eddy current sensor with an encircling coil could effectively estimate the diatreter change due to deteriorations in overhead distribution lines. lines.

  • PDF

Acquisition of Multi-channel Biomedical Signals Based on Internet of Things (사물인터넷 기반의 다중채널 생체신호 측정)

  • Kim, Jeong-Hwan;Jeung, Gyeo-Wun;Lee, Jun-Woo;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1252-1256
    • /
    • 2016
  • Internet of Things(IoT)-devices are now expanding inter-connecting networking technologies to invent healthcare monitoring system especially for assessing physiological conditions of the chronically-ill patients those with cardiovascular diseases. Hence, IoT system is expected to be utilized for home healthcare by dedicating the original usage of IoT devices to collect the biomedical data such as electrocardiogram(ECG) and photoplethysmography(PPG) signal. The aim of this work is to implement health monitoring system by integrating IoT devices with Raspberry-pi components to measure and analyze ECG and the multi-channel PPG signals. The acquired data and fiducial features from our system can be transmitted to mobile devices via wireless networking technology to support the concept of tele-monitoring services based on IoT devices.

Application of Principle Component Analysis and Measurement of Ultra wideband PD signal for Identification of PD sources in Air (기중부분방전원 식별을 위한 광대역 부분방전신호의 측정 및 주성분분석기법의 적용)

  • Lee, K.W.;Kim, M.Y.;Park, D.W.;Shim, J.B.;Chang, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.505-506
    • /
    • 2006
  • PD(partial discharge) occurred from variable PD sources in air may be the cause of breakdown in high voltage equipment which affect huge outage in power system. Identification and localization of PD sources is very important for engineer to cope with huge accident beforhand. PD phenomena can be detected by acoustic emission sensor or electromagnetic sensor like antenna. This paper has investigated the identification method using PCA(principal component analysis) for the PD signals from variable PD sources, for which the electric field distribution and PD inception voltages were simulated by using commercial FEM program. PD signals was detected by ultra wideband antenna. Their own features were extracted as the frequency coefficients transformed with FFT(fast fourier transform) and used to obtain independent pincipal components of each PD signals.

  • PDF

Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement (고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

Case study of microseismic techniques for stability analysis of pillars in a limestone mine (석회석 광산 내 광주의 안정성 분석을 위한 미소진동 계측기술의 현장적용)

  • Kim, Chang Oh;Um, Woo-Yong;Chung, So-Keul;Cheon, Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • This study deals with the case that was the field application of the microseismic monitoring techniques for the stability monitoring in a domestic mine. The usefulness and limitations of the microseismic techniques were examined through analyzing the microseismic monitored data. The target limestone mine adopted a hybrid room-and-pillar mining method to improve the extraction ratio. The accelerometers were installed in each vertical pillar within the test bed which has the horizontal cross-section $50m{\times}50m$. The measured signals were divided into 4 types; blasting induced signal, drilling induced signal, damage induced signal, and electric noise. The stability analysis was performed based on the measured damage induced signals. After the blasting in the mining section close to the test bed, the damage of the pillar was increased and rockfall near the test bed could be estimated from monitored microseismic data. It was possible to assess the pillar stability from the changes of daily monitored data and the proposed safety criteria from the accumulated monitored data. However, there was a difficulty to determine the 3D microseismic source positions due to the 2D local sensor arrays. Also, it was needed to use real-time monitoring methods in domestic mines. By complementing the problems encountered in the mine application and comparing microseismic monitored data with mining operations, the microseismic monitoring technique can be used as a better safety method.

Electrical Behavior of the Circuit Screen-printed on Polyimide Substrate with Infrared Radiation Sintering Energy Source (열소결로 제작된 유연기판 인쇄회로의 전기적 거동)

  • Kim, Sang-Woo;Gam, Dong-Gun;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.71-76
    • /
    • 2017
  • The electrical behavior and flexibility of the screen printed Ag circuits were investigated with infrared radiation sintering times and sintering temperatures. Electrical resistivity and radio frequency characteristics were evaluated by using the 4 point probe measurement and the network analyzer by using cascade's probe system, respectively. Electrical resistivity and radio frequency characteristics means that the direct current resistance and signal transmission properties of the printed Ag circuit. Flexibility of the screen printed Ag circuit was evaluated by measuring of electrical behavior during IPC sliding test. Failure mode of the Ag printed circuits was observed by using field emission scanning electron microscope and optical microscope. Electrical resistivity of the Ag circuits screen printed on Pl substrate was rapidly decreased with increasing sintering temperature and durations. The lowest electrical resistivity of Ag printed circuit was up to $3.8{\mu}{\Omega}{\cdot}cm$ at $250^{\circ}C$ for 45 min. The crack length arisen within the printed Ag circuit after $10{\times}10^4$ sliding numbers was 10 times longer than that of after $2.5{\times}10^4$ sliding numbers. Measured insertion loss and calculated insertion loss were in good agreements each other. Insertion loss of the printed Ag circuit was increased with increasing the number of sliding cycle.

Impedance Changes of Living Tissue During Radiation Exposure Dose (방사선 피폭선량에 대한 생체 조직의 임피던스 변화)

  • Kil, Sang Hyeong;Lee, Moo Seok;Nam, Ji Ho;Lee, Yeong Hwa;Kim, Gun Do;Lee, Jong Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.202-207
    • /
    • 2013
  • Bioimpedance involves a lot of information related to living tissue. If there is alteration in bio tissue, its electrical characteristics also change. It is to study electrical characteristics of pork tenderlion in using a HP-4194A Impedance/Gain-phase analyzer instrument and electrical characteristics changes by graded radiation exposure dose. The results were as follow 1. Electrical characteristics of pork tenderlion in repeated measurement had high precision within ${\pm}5$% of coefficiency of variability. 2. During the measurement impedance absolute value and phase alteration did not show statistically significant difference.(p>0.05) 3. While impedance phase of electrical characteristics associated with frequency change was almost stable, impedance absolute value was in inverse proportion to frequency that means high inverse correlation of -0.096(r). 4. Impedance absolute value dropped in radiation exposure dose. The alteration of the value did not show statistically significant difference in 1 Gy, 2 Gy and 4 Gy.(p>0.05) However in radiation exposure dose of 10 Gy, the decrease of impedance absolute value was significantly different.(p<0.05) 5. Impedance phase according to radiation exposure dose change did not show statistically significant difference in 1 Gy, 2 Gy, 4 Gy, and 10 Gy(p>0.05).

A Study on Selective Metal Ion Sensing Membrane for Bio Environment Measurement (바이오 환경측정용 선택적 금속이온 감지 막의 특성 연구)

  • Park, Hyung-Jun;Jang, Gab-Soo;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1062-1067
    • /
    • 2018
  • In this study, the research processed with a chemical sensor for measuring trace amount of heavy metal ions which is based on the requirements of the efficient sensing technology as recent equipment is applies molecular system in the chemical sensing section that can precisely recognizing selective target substance and transmit its data to physical signal as a result. In this research is concentrated on realize highly precise by utilizing SPR sensor application of recognition functional sensing membrane. Consequently, according to DTSQ-dye sensing membrane, the resonance angle from low-concentration to the highest concentration $10^{-4}M$ of $Ag^+$ ion is $2.17[^{\circ}]$ and this result indicating 4.3 times larger resonance angle changes compare to the other metal substance. Based on SQ-dye sensing membrane, the difference of resonance angle between low concentration and the highest concentration $10^{-4}M$ of $Cu^{2+}$ ion is $2.3[^{\circ}]$ and this outcome is indicating 4.5 times greater resonance angle change to the other metal substance.

The Hearing Ability of the Dusky spinefoot Siganus fuscescens(Houttuyn)to Audible Sound 2. The Auditory Critical Ratio (가청음에 의한 독가시치의 청각 능력 2. 청각 임계비)

  • Lee, Chang-Heon;Moon, Jong-Wook;Seo, Du-Ok
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.12 no.2
    • /
    • pp.191-198
    • /
    • 2000
  • An experiment was carried out to obtain the fundamental data on the auditory thresholds of fishes for catching method using audible frequency sound, the auditory thresholds of dusky spinefoot Siganus fuscescens(Houttuyn) were measured in the presence of masking noise in the spectrum level range of 74 - 83dB re $1{\mu}Pa/{\sqrt{Hz}}$ by heartbeat conditioning technique using pure tones coupled with a delayed electric shock. The auditory critical ratios were about 23 - 34dB at measurement frequency range. The ratio increased almost linearly with increasing frequency from 200 to 500Hz. The noise spectrum level at the start of masking was about 61 - 73dB within the measurement frequency range. This suggests that hearing of dusky spinefoot is masked in the natural environment with the noise spectrum level above 70dB. The sound pressure level of which the signal sound of 100Hz is recognized by dusky spinefoot under the white noise of 70dB is above 98dB and the critical ratio of them is above 23dB.

  • PDF

Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method (초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operating conditions such as high temperature and high pressure for an extended period time. Conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also these techniques have low practicality and applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens(Cr-Mo alloy steels) were carried out for the purpose of evaluation for creep damage. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradation tests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens. we conformed that both the sound velocity decreased and attenuation coefficient linearly increased in proportion to the Increase of creep life fraction($\Phi$c).

  • PDF