• Title/Summary/Keyword: 적층 고무베어링

Search Result 22, Processing Time 0.015 seconds

Passive Control System for Mitigation of Cable Vibration in Cable-Stayed Bridges (사장교의 케이블 진동저감을 위한 수동 제어시스템)

  • Hwang, Inho;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.881-885
    • /
    • 2006
  • Rain-wind induced cable vibration can cause serious problems in cable-stayed bridges. Externally attached dampers have been used to provide an effective means to suppress the vibration of relatively short stay-cables. For very long stay-cables, however, such damper systems are rendered ineffective, as the dampers need to be attached near the end of cables for aesthetic reasons. This paper investigates a new control system to mitigate the cable vibration. The proposed control system which consists of a laminated rubber bearing and an internal damper may be installed inside of the cable anchorage. A simple analytical model of the cable-damper system is developed first based on the taut string representation of the cable. The response of a cable with the proposed control system is obtained and then compared to those of the cable with and without an external passive damper. The proposed stay-cable vibration control system is shown to perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges for mitigation of rain-wind induced vibration of stay-cables.

Shaking Table Test of a 1/10 Scale Isolated Fifteen-story Flat Plate Apartment Building (면진층을 가지는 1/10 축소된 15층 무량판 아파트건물의 진동대 실험)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.287-297
    • /
    • 2011
  • This paper presents the results of performance verification tests of the isolated flat plate apartment building with the laminated rubber bearings. The shaking table test is carried out in CABR(China Academy of Building Research) with two 1/10 scale isolation and non-isolation models under 4 excitation waves. The shaking table test is proceeding from x axis, y axis and x+y axis with different amplitude of acceleration values. The results show that, to non-isolated model, the natural vibration period is remarkably decreased and entered non-linear condition after moderate earthquake. Its accelerations become lager with increasing storey number and completely collapsed under large earthquake. The inter-storey shifts largely exceed the limit values of regulated displacement angles. But to isolated model, the natural vibration period of isolated modal is almost the same in all conditions and still in its elastic condition. The earthquake loading is greatly reduced and the accelerations of superstructure are greatly reduced. The inter-storey drifts are very small and can be neglected. The isolated model is in translational state and can be seen as a rigid whole. The displacements of isolation layer are in the allowable range. This experiment demonstrates that the seismic isolation is very effective to mitigate the influence of earthquake on structures and it is possible to increase the serviceability due to decrease the floor acceleration. facilities from their good states that is superior to non-isolated structure.