• Title/Summary/Keyword: 적절한 보강방법

Search Result 164, Processing Time 0.032 seconds

Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior- (절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰-)

  • Hwang, Yoon Koog;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.363-375
    • /
    • 1997
  • This study encompasses the performance of static and fatigue test for the 8 large scale test specimens to clarify the fatigue behavior of coped stringer and the effect of the repair and strengthening on the damaged stringer of the floor system in steel railway bridges. For the purpose of the research, the actual stress wave for the existing bridge was measured, the basic stress range frequency histogram was made and the equivalent stress range was calculated. Using the result from the equivalent stress range made by adjusting the stress range, the static and fatigue test was carried out by identifying the previous rehabilitation and after. As the result of the static tests, it was revealed that the level of local stress under the S1 specimen test of the real equivalent stress range was similar to tensile strength of the test material, and it was consistent with the requirement of the initiation condition of the fatigue crack. Through the various rehabilitation methods to the damaged specimens, the effects of the repair and reinforcement were analyzed. According to the results of the repair of effect, bolting the high tension bolt over the stop hole was confirmed to be more adequate method than drilling only stop hole to delay the fatigue crack growth. Futhermore, in case of the stringer subjected by bending moment, the reinforcement over the upper flange side was determined to be a useful strengthening method, and the reinforcement to the web of the stringer was not appropriate to accomodate as a adequate strengthening method. Also it was confirmed that the category of the fatigue design for the coped stringer met with the category E specified on the fatigue design criteria of the Highway Standard Specification in Korea.

  • PDF

Reinforcing Effects around Face of Soil-Tunnel by Crown & Face-Reinforcing - Large Scale Model Testing (천단 및 막장면 수평보강에 의한 토사터널 보강효과 - 실대형실험)

  • Kwon Oh-Yeob;Choi Yong-Ki;Woo Sang-Baik;Shin Jong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.6
    • /
    • pp.71-82
    • /
    • 2006
  • One of the most popular pre-reinforcement methods of tunnel heading in cohesionless soils would be the fore-polling of grouted pipes, known as RPUM (reinforced protective umbrella method) or UAM (umbrella arch method). This technique allows safe excavation even in poor ground conditions by creating longitudinal arch parallel to the tunnel axis as the tunnel advances. Some previous studies on the reinforcing effects have been performed using numerical methods and/or laboratory-based small scale model tests. The complexity of boundary conditions imposes difficulties in representing the tunnelling procedure in laboratory tests and theoretical approaches. Full-scale study to identify reinforcing effects of the tunnel heading has rarely been carried out so far. In this study, a large scale model testing for a tunnel in granular soils was performed. Reinforcing patterns considered are four cases, Non-Reinforced, Crown-Reinforced, Crown & Face-Reinforced, and Face-Reinforced. The behavior of ground and pipes as reinforcing member were fully measured as the surcharge pressure applied. The influences of reinforcing pattern, pipe length, and face reinforcement were investigated in terms of stress and displacement. It is revealed that only the Face-Reinforced has decreased sufficiently both vertical settlement in tunnel heading and horizontal displacement on the face. Vertical stresses along the tunnel axis were concentrated in tunnel heading from the test results, so the heading should be reinforced before tunnel advancing. Most of maximum axial forces and bending moments for Crown-reinforced were measured at 0.75D from the face. Also it should be recommended that the minimum length of the pipe is more than l.0D for crown reinforcement.

Shear Behavior of Reinforced Concrete Beams Strengthened with Unbonded-Type Wire Rope Units (비 부착형 와이어로프로 보강된 철근콘크리트 보의 전단 거동)

  • Kim, Sun-Young;Byun, Hang-Yong;Sim, Jae-Il;Chung, Heon-Soo;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.83-90
    • /
    • 2007
  • The present study reports a simple unbonded-type shear strengthening technique for reinforced concrete beams using wire rope units. Fifteen beams failed in shear were repaired and strengthened with wire rope units, and then retested to failure. Influence of the prestressing force, orientation and spacing of wire rope units on the shear behavior of strengthened beams having shear span-to-depth ratios of 1.5, 2.5, or 3.25 were investigated. Test results showed that beams strengthened with wire rope units exhibited a higher shear strength and a larger post-failure deformation than the corresponding original beams. Inclined wire rope units was more effective for shear strength enhancement than vertical wire rope units. The increase of the prestressing force in wire rope units causes the decrease of the principal tensile stress in concrete, as a result, the diagonal tensile cracking strength of strengthened beams was higher than that of the corresponding original beams. Shear capacity of strengthened beams is compared with predictions obtained from ACI 318-05 and EC 2. Shear capacity of strengthened beams having shear span-to-depth ratio below 2.5 is reasonably predicted using ACI 318-05 formula. On the other hand, EC 2 overestimates the shear transfer capacity of wire rope units for beams having shear span-to-depth ratio above 2.5.

A Study on Insulation Performance Enhancement of Existing Transmission Line Considering Overvoltage Analysis Result and Fault Characteristic (과전압 분석 결과와 고장특성을 고려한 기설 송전선로의 절연보강 방법에 관한 연구)

  • Kwak, Joo-Sik;Woo, Jung-Woog;Koo, Kyo-Sun;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.162-168
    • /
    • 2009
  • This paper describes a study that is to redesign insulation of transmission lines and determine required the numbers of insulators in order to enhance the insulation performance of existing transmission lines which were constructed with standard insulation design, considering overvoltage analysis results, probabilities and characteristics of faults. To ensure proper insulation distance without deteriorating the required performance, EMTP model is established to calculate maximum overvoltage in the line. The fault records and predicted outage rates due to lightning and contamination in the line were investigated and analyzed respectively. It presents a method to determine the numbers of insulators considering the probability and the characteristic of fault.

Fiber Type Effects on the Flexural Behavior of Steel Fiber Reinforced Concrete Beams (강섬유의 형태에 따른 SFRC보의 휨거동에 관한 연구)

  • Jeon, Chan Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.95-106
    • /
    • 1992
  • This paper presents a comparative evaluation of five different types of steel fibers used as reinforcing material in concrete beams. Two types of plain and RC beams were prepared to compare the relative flexural behavior. The fibers used were dog bone (paddled), both ends hooked. コ-type straight. crimped and wavy type with aspect ratio of 43 to 75. Fiber volume fraction of 1 to 2% were used while shear span to depth ratio (aid) and steel ratio p were fixed. Fiber reinforcement effect index Ef and effective toughness index Te were adopted to evaluate fiber reinforcing effects. The effect of fiber reinforcement on flexural strength is higher in plain beams than in RC beams. Hooked and dog bone type fibers were found to be more effective than the other type ones in enhancing the flexural strength and post-peak energy absorption capacity of concrete beams.

  • PDF

A Methodology of Seismic Damage Assessment Using Capacity Spectrum Method (능력 스펙트럼법을 이용한 건물 지진 손실 평가 방법)

  • Byeon, Ji-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.1-8
    • /
    • 2005
  • This paper describes a new objective methodology of seismic building damage assessment which is called Advanced Component Method(ACM). ACM is a major attempt to replace the conventional loss estimation procedure, which is based on subjective measures and the opinions of experts, with one that objectively measures both earthquake intensity and the response ol buildings. First, response of typical buildings is obtained analytically by nonlinear seismic static analysis, push-over analyses. The spectral displacement Is used as a measure of earthquake intensity in order to use Capacity Spectrum Method and the damage functions for each building component, both structural and non-structural, are developed as a function of component deformation. Examples of components Include columns, beams, floors, partitions, glazing, etc. A repair/replacement cost model is developed that maps the physical damage to monetary damage for each component. Finally, building response, component damage functions, and cost model were combined probabilistically, using Wonte Carlo simulation techniques, to develop the final damage functions for each building type. Uncertainties in building response resulting from variability in material properties and load assumptions were incorporated in the Latin Hypercube sampling technique. The paper also presents and compares ACM and conventional building loss estimation based on historical damage data and reported loss data.

Posterior and Posterolateral Instability of Knee Joint (후방 및 후외측 불안정성 슬관절)

  • Lee, Dong-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.127-136
    • /
    • 2003
  • Posterolateral instability of the knee occurs more commonly in association with an injury to anterior and posterior cruciate ligament and combined injuries are severe injuries that result in significant functional instability and articular cartilage degeneration. Reconstruction of the anterior and posterior cruciate ligament without an appropriate treatment of posterolateral corner injury result in failure of the reconstructed cruciate ligaments. Meticulous physical examinations, imaging studies, lower limb alignment and gait pattern should be evaluated. Acute grade III isolated or combined injury of the posterolateral corner is best treated within three weeks by direct repair, or augumentation, or reconstruction. The appropriate surgical method or combined methods are selected among the several methods of posterior and posterolateal reconstruction, and all injuried posterolateral and cruciate ligament structures are anatomically reconstructed simultaneously or by stages. If a varus alignment and varus thrust is disclosed in chronic posterolateral instability of knee, soft tissue reconstructions laterally are highly unlikely to be able to correct tile problem. It is appropriate that valgus osteotomy should be done before soft tissue reconstruction and reevaluate the posterolateral instability about 6 months later.

  • PDF

The Suggestion of Testing Method for Analysis of Tensile Strength of Multi-Directional GFRP Plate (다방향 GFRP 플레이트의 인장강도 분석을 위한 시험 방법 제안에 관한 연구)

  • Sim, Jong-Sung;Kwon, Hyuck-Woo;Lee, Hyoung-Ho;Kim, Hyun-Joong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.799-808
    • /
    • 2011
  • In this study, a standardized test method to analyze tensile properties of multi-directional GFRP plate was proposed. Presently, tensile strength test of FRP composite reinforced with isotropic and orthotropic fiber is standardized according to ISO standard. Also, even though many studies were performed on test method to analyze the dynamic properties, the properties of tensile strength for multi-directional GFRP plate were not clearly identified. Currently, the domestic test method in accordance with ASTM, which is applicable to unidirectional FRP plate, gave tensile test results greater than actual properties. Thus, in this study, GFRP tensile test was conducted using the method found to be commonly applicable to all standards based on literature review of domestic and international references. Then, anchorage length experiments were performed using the proposed tension test method to evaluate validity of the method. Finally, optimal anchorage length was estimated from the numerical analysis to propose the standardized tensile strength method for GFRP multi-directional composite evaluation.

Water Quality Analysis of Bogang stream using QUAL2E Water Quality Model (QUAL2E 하천수질모형을 이용한 보강천 수질모의 분석)

  • Park, Jung-Ha;Lee, Sang-Kil;Bae, Myoung-Soon;Jeong, Si-Mon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.674-679
    • /
    • 2008
  • 수질모델링은 제한된 공간에서 실측된 자료를 바탕으로 임의지점에서의 수질을 예측하는 것으로서 수체로 유입되는 오염원의 변화에 대한 수질의 변화를 예측, 장래 개발계획 및 수질정책에 대한 영향평가 등에 활용될 수 있다. 하천 및 호소로 유입되는 오염물질을 통제하고 과학적으로 관리하기 위해서는 수질모델링 과정을 정확히 이해하고 관련모델을 적절히 적용하여야 한다. 최근 수질오염총량제가 시행되고 있는 시점에서 지자체간 갈등을 줄이고 지역의 균형발전을 위해서는 합리적이고 과학적인 수질모델링 과정이 필요하다. 따라서 본 연구에서는 금강 수계 미호천의 지류인 보강천을 대상으로 QUAL2E 하천수질모형을 구축함으로써 해당 수계에 인접한 지자체들이 원활이 수질오염총량관리제도를 시행할 수 있게 정확하고 합리적인 수질예측 결과를 제시하고자 한다. 본 연구에서는 QUAL2E 하천수질모형을 구축하기 위해서 유량자료는 2007년 10월부터 12월까지 총 8회에 걸쳐 측정한 유량 데이터를 이용하였고 수리계수는 보강천 하천정비기본계획(건설교통부, 1991)에 실려있는 하천단면 자료를 이용한 HEC-RAS 수리모형을 이용하여 산정하였다. 하천 수질 자료는 2007년 10월부터 12월까지 총 8회에 걸쳐 유량과 함께 측정한 수질자료를 이용하였고 유달계수는 S. R. HA and M. S. Bae(2003, 2004, 2005, 2006), 박정하 등(2007)이 제안한 방법을 이용하여 산정하였다. 분석 결과, 보강천에 영향을 미치는 지자체는 증평군, 진천군, 괴산군, 음성군이며 그 중 유역면적을 많이 차지하고 있는 증평군과 진천군의 영향이 큰 것으로 나타났고, 미호천 하류에 위치한 미호B 목표수질관리지점의 목표수질인 4.3 mg/L BOD를 만족하는 것으로 분석되었다.

  • PDF

Experimental Study on Setting Time of Cement Paste Mixed Accelerating Admixtures (급결제를 혼합한 시멘트페이스트의 응결시간에 관한 실험적 연구)

  • Heo Gweon;Choi Hong-Shik;Yi Seong-Tae
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.879-884
    • /
    • 2005
  • The setting time is a very important factor affecting the quality of tunnel lining and reinforcement of inclined slope etc. Currently, however, the quality criteria of accelerating admixture to improve it is not established well. In this study, evaluation on setting time measuring methods of cement mixed a accelerating admixture (AA) was performed using Gillmore and Vicat needle test methods. For both test methods, the setting time for addition at a time was better than post addition regardless of initial setting and final setting. For Gillmore needle test method, two types of measuring methods were selected and it is noted that setting time with cement type under the same accelerating admixture can be different. Accordingly, manufacturing company shall develop a less sensitive accelerating admixture to cement type. For Vicat needle test method, six types of measuring methods were used and a proper measuring method of the admixture were proposed as follows: (1) the temperature of materials used shall be controlled exactly and (2) to evaluate its properties, an admixture usage of $5\%$ (ratio of cement weight) is recommended.