• Title/Summary/Keyword: 적외선분광기

Search Result 36, Processing Time 0.029 seconds

Evaluation of Field Application of Portable Near Infrared Reflectance Spectrometer (NIRS) for Quality Evaluation of Italian Ryegrass Silages (신속한 이탈리안라이그라스 사일리지의 품질평가를 위한 소형 근적외선분광기(NIRS)의 현장 적용성 평가)

  • Park, Hyung-Soo;Lee, Sang-Hoon;Kim, Jong-Gun;Choi, Ki-Choon;Seo, Sung;Kim, Won-Ho;Lee, Hyo-Won;Lim, Young-Chul
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.31 no.4
    • /
    • pp.415-422
    • /
    • 2011
  • This study evaluated the feasibility of using a portable near infrared reflectance spectrometer working in the 900~1,600 nm range for the measurement of quality-related parameters (moisture, pH, Acid detergent fiber (ADF), Neutral detergent fiber (NDF), Crude protein (CP), lactic acid) in intact silage. The calibration result for the Phazir (handheld, Polychromix) was compared with the result for the Spectrastar (Lab. based, Unity). A total of 67 Italian ryegrass silages were used to build calibration models using different spectral signal pre-treatments and the partial least squares regression (PLS) method. The good calibration statistics in two instruments was obtained for moisture content of Italian ryegrass silages with over $R^2$ = 0.95. The Phazir spectrometer was less accurate in measuring of ADF, NDF and CP contents. The Spectrastar instrument yielded greater precision for pH and lactic acid content; statistic values were over $R^2$ = 0.82 and the standard error of calibration (SEC) = 0.21% and 0.24%. Thus, the NIR measurement of forage quality in the field by portable NIR analyzers was shown not to be feasible, but additional investigations are required to discern the key instrumental and operational parameters that may influence the portable NIR measurement.

A Study on the Submergence Test of the Distribution Polymer Surge Arrester (침수시험에 의한 비전용 폴리머피뢰기의 특성연구)

  • Kim, Ju-Yong;Kwon, Tae-Ho;Song, Il-Keun;Lee, Jae-Bong;Kim, Dong-Myung;Jeong, Yeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.104-106
    • /
    • 2003
  • 본 논문은 이상전압으로부터 배전선로 및 전력기기를 보호하기 위해 사용되는 폴리머피뢰기에 대해 침수 시험을 실시하여 침수 전후 폴리머피뢰기의 특성변화를 평가하였다. 침수 시험은 수온 95[$^{\circ}C$]에서 20일 동안 실시하였다. 침수 시험 전후 폴리머피뢰기의 특성분석은 푸리에변환 적외선분광기(FTR : fourier transform infrared spectrophotometer), 유전열분석(DETA : dielectric thermal analyzer), 발수성 측정, 절연저항 측정, 누설전류 측정, 동작개시전압 측정 둥으로 연구 하였다. 이를 통해 침수시험의 열화 효과에 대해 검토하였다.

  • PDF

태양전지모듈용 EVA의 가속 열화 메카니즘

  • Jeong, Jae-Seong;U, Dong-Jin;Park, No-Chang;Han, Chang-Un;Hong, Won-Sik
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.49.1-49.1
    • /
    • 2011
  • 태양전지 모듈의 25년 이상 보증을 위해 태양전지 모듈을 구성하는 부품 소재의 신뢰성이 부각되고 있다. 현재까지 알려진 태양전지 모듈용 에틸렌 아세테이트 비닐(ethylene Vinyl Acetate, EVA)의 주요 열화 메카니즘은 황변(yellowing)과 박리(delaminaation)이다. 따라서 본 연구에서는 태양전지 모듈을 구성하는 재료 중 EVA 소재의 열화 메커니즘을 도출하기 위해 이미 알려진 스트레스 인자를 이용한 가속 열화시험을 설계한 후 가속열화시험을 실시하였으며, 이로부터 EVA의 열화 메카니즘을 규명하였다. 열화모드 재현을 위해 소형 태양광 모듈을 제작하였으며, Weather-Ometer를 이용하여 열화시험을 수행하였다. 시험조건은 4종 Phase가 1 사이클이 되도록 실험하였으며, Dark 조건 1 Phase 및 Light 조건 3 Phase 조건으로 실시하였다. 태양전지 모듈의 열화량은 매 500 사이클 마다 Light I-V 변화량을 측정하여 분석하였다. EVA의 물리 화학적 열화분석을 위해 단면분석, 적외선분광기(Fourier Transform-Infra Red, FT-IR) 및 주사전자현미경을 이용하여 열화 특성에 대한 분석을 실시하였고, 이를 근거로 EVA의 열화 메커니즘을 규명하였다.

  • PDF

Synthesis and Characterization of Doped Silicon Nanoparticles by a Solution Route (용액 공정을 통한 도핑된 실리콘 나노입자의 합성과 특성)

  • Kwon, Ha-Young;Lim, Eun-Hee;Lee, Sung-Koo;Lee, Kyeong-K.
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.694-696
    • /
    • 2010
  • We have synthesized boron (or phosphorous) doped silicon nanoparticles (Si-NPs) by a solution process. The surfaces of the Si-NPs were terminated with various alkyl groups to form a protecting layer. The Si-NPs were characterized by UV-Vis, PL, FTIR, and NMR. Through a microwave sintering process, the crystalline thin films of the Si-NPs were prepared by removing the surface alkyl groups. The TEM and SEM images reveal that contiguous films as large as $200{\mu}m$ in diameter were formed with a cubic structure. The electrical conductivity of the Si film was controlled by a doping type.

Preparation of Cobalt-Substituted Iron Oxide Powder from Organometallic Precursors (Ⅱ) (유기금속 전구체로부터 코발트 치환 산화철 분말 제조 (Ⅱ))

  • Kim, Jeong Su;Gang, Han Cheol;Hong, Yang Gi
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.92-100
    • /
    • 1994
  • Ultrafine cobalt-substituted iron oxide particles were prepared by the thermal decomposition and oxidation of the new organometallic precursor, $Co_xFe_{1-x}(N_2H_3COO)_2(N_2H_4)_2$ (x = 0, 0.01, 0.02, 0.03, 0.05, 0.10, 1.00). The organometallic precursors were synthesized by the reaction of Co(II) and Fe(II) ion in a mole ratio of x : 1-x with hydrazinocarboxylic acid, and characterized by quantitative analysis, elemental analysis and infrared spectroscopy. The mechanistic study on the thermal decomposition of the organometallic precursors was performed by TG-DTG and DSC. The cobalt-substituted iron oxide particles were obtained by the heat treatment of the precursors at $350^{\circ}C$ and $450^{\circ}C$ for six hours in air. The prepared iron oxide was found to have two phases such as ${\gamma}-Fe_2O_3$ and a mixture of ${\gamma}-Fe_2O_3\;and\;{\alpha}-Fe_2O_3$ at $350^{\circ}C$ and $450^{\circ}C$ respectively. The particle shape was equiaxial and the particle size was less than 0.05 ${\mu}m.$ The coercivity and squareness of the cobalt substituted iron oxide particles increased with increasing cobalt content. Both coercivity and squareness showed higher values at $450^{\circ}C.$

  • PDF

A Study on Remote Analysis of Fire Gas Using Open Path FT-IR (개방형 적외선분석기를 사용한 원거리 화재발생가스 측정에 관한 연구)

  • Cho, Nam-Wook;Lee, In-Gu;Lee, Jong-Cheon
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.39-45
    • /
    • 2013
  • The gas generated from the fire which is continuous until material is completely burned. We can analyze usual gas using chromatography analysis but it can not be applicated to analyze for the gas from the fire because which gas is enormously generated. Besides, chromatography analysis has the disadvantage that it can not continuously analyze the sample's representativness, gas from the fire, Fourier transform infrared spectroscopy, FT-IR, has been utilized for effective combustion gas analysis method in small-scale combustion and on-line analysis has been attempted continuously. However, continuous sampling of 3.5l/min can not be representativness of sample if the gas caused by a massive fire and space. And the gas sampling is practically impossible in such a case. In this study, we attempted remote analysis while overcoming the disadvantages of the current gas analysis by using an Open-Path Infrared Analyzer without pre-treatment of the sampling. For the remote analysis, quantitative analysis method was established regarding each combustion toxic gases. And we measured the gases from the fire that occurs in the real case.